TW | Thermoplastic moisture-resistant building wire, 60 C (600 V, 60 C dry and wet) |
THW | Thermoplastic heat- and moisture-resistant building wire, 75 C (600 V, 75 C dry and wet) |
THHW | Thermoplastic high heat-resistant, moisture-resistant building wire (600 V, 90 C dry, 75 C wet) |
THWN | Thermoplastic heat- and water-resistant nylon-coated building wire, 75 C (600 V, 75 C wet and dry) |
THHN | Thermoplastic high heat-resistant nylon-coated building wire (600 V, 90 C dry and damp locations) |
THWN-2 | Thermoplastic heat- and water-resistant nylon-coated building wire, 90 C wet or dry (600 V, 90 C wet and dry locations) |
MTW | Machine tool wire, oil-resistant PVC, 90 C (600 V, 90 C dry, 60 C wet or oil) |
XHH | Thermoset (XLPE) high heat-resistant building wire, dry and damp locations (600 V, 90 C dry and damp) |
XHHW | Thermoset (XLPE) high heat-resistant building wire, wet locations at 75 C (600 V, 90 C dry, 75 C wet) |
XHHW-2 | Thermoset (XLPE) high heat-resistant building wire, 90 C wet or dry (600 V, 90 C wet and dry) |
RHH | Thermoset (rubber-type) high heat-resistant building wire, dry and damp (600 V, 90 C dry and damp) |
RHW | Thermoset (rubber-type) heat- and moisture-resistant building wire, 75 C (600 V, 75 C dry and wet) |
RHW-2 | Thermoset (rubber-type) heat- and moisture-resistant building wire, 90 C wet or dry (600 V (2 kV on some listings), 90 C wet and dry) |
USE | Underground service-entrance conductor (single wire), 75 C (600 V, 75 C) |
USE-2 | Underground service-entrance conductor, 90 C wet or dry (600 V, 90 C wet and dry) |
TBS | Thermoplastic-insulated, braid-covered switchboard wire (600 V, 90 C) |
SIS | Switchboard and control wire, cross-linked polyethylene, 90 C (600 V, 90 C) |
TFFN | Thermoplastic flexible fixture wire, nylon-coated (600 V, 90 C) |
TFN | Thermoplastic fixture wire, nylon-coated (solid conductor) (600 V, 90 C) |
TFF | Thermoplastic flexible fixture wire, no nylon (600 V, 60 C (UNVERIFIED)) |
TF | Thermoplastic fixture wire, no nylon (600 V, 60 C) |
NM-B | Non-metallic sheathed cable, type B (90 C conductors), for dry indoor wiring (600 V, 90 C conductors (ampacity at the 60 C column)) |
UF-B | Underground feeder cable, type B, sunlight-resistant gray jacket, direct burial (600 V, 90 C conductors (ampacity at the 60 C column)) |
SE | Service-entrance cable (general term, SER round or SEU flat) (600 V, 75 or 90 C) |
SER | Service-entrance cable, style R (round), with a bare ground, gray jacket (600 V, 90 C (XLPE) or 75 C (PVC)) |
SEU | Service-entrance cable, style U (flat), with a concentric bare neutral, gray jacket (600 V, 90 C (XLPE) or 75 C (PVC)) |
URD | Underground residential distribution cable, twisted aluminium conductors, direct burial (600 V, 90 C XLPE) |
MOBILE HOME FEEDER | Mobile home feeder: three aluminium alloy conductors and an insulated ground, XLPE insulated (USE-2 / RHH / RHW-2), direct burial (600 V, 90 C wet or dry) |
AC | Armored cable (BX): insulated conductors with a 16 AWG aluminium bond wire in interlocked steel armour, no outer jacket (600 V, 90 C conductors (AC-90 / ACHH)) |
MC | Metal-clad cable: insulated conductors and a green ground in interlocked metal armour (600 V, 90 C conductors) |
MC-HL | Metal-clad cable for hazardous locations: continuous corrugated aluminium sheath and PVC jacket (600 V or 1000 V, 90 C (XHHW-2)) |
TC | Tray cable: multiconductor power or control cable for cable trays (600 V, 90 C dry, 75 C wet) |
TC-ER | Tray cable, exposed run: may run outside tray or conduit up to 6 ft, supported and secured (600 V, 90 C dry, 75 C wet) |
TC-ER-HL | Tray cable, exposed run, hazardous locations (600 V, 90 C dry, 75 C wet) |
ITC | Instrumentation tray cable, shielded pairs, for circuits up to 150 V and 5 A (300 V) |
ITC-ER | Instrumentation tray cable, exposed run (300 V) |
PLTC | Power-limited tray cable, shielded pairs, 300 V (300 V) |
PLTC-ER | Power-limited tray cable, exposed run (300 V) |
MV-90 | Medium-voltage shielded power cable, 90 C (2 kV to 35 kV, 90 C) |
MV-105 | Medium-voltage shielded power cable, 105 C (2 kV to 35 kV, 105 C) |
AEIC-CS9 | High voltage XLPE power cable, single conductor, 69 to 345 kV, as the makers print its legend (size, metal, wall in mils, class) (69, 115, 138, 161, 230 and 345 kV, 90 C) |
S | Standard thermoset flexible cord (600 V, 90 C) |
SO | Standard thermoset flexible cord, oil-resistant (600 V, 90 C) |
SOO | Standard thermoset flexible cord, oil-resistant (600 V, 90 C) |
SOW | Standard thermoset flexible cord, oil-resistant, weather-resistant (600 V, 90 C) |
SOOW | Standard thermoset flexible cord, oil-resistant, weather-resistant (600 V, 90 C) |
SJ | Junior thermoset flexible cord (300 V, 90 C) |
SJO | Junior thermoset flexible cord, oil-resistant (300 V, 90 C) |
SJOW | Junior thermoset flexible cord, oil-resistant, weather-resistant (300 V, 90 C) |
SJOOW | Junior thermoset flexible cord, oil-resistant, weather-resistant (300 V, 90 C) |
SJT | Junior thermoplastic flexible cord (300 V, 60 to 105 C) |
SJTW | Junior thermoplastic flexible cord, weather-resistant (300 V, 60 to 105 C) |
SJTO | Junior thermoplastic flexible cord, oil-resistant (300 V, 60 to 105 C) |
SJTOW | Junior thermoplastic flexible cord, oil-resistant, weather-resistant (300 V, 60 to 105 C) |
SJTOOW | Junior thermoplastic flexible cord, oil-resistant, weather-resistant (300 V, 60 to 105 C) |
ST | Standard thermoplastic flexible cord (600 V, 60 to 105 C) |
STW | Standard thermoplastic flexible cord, weather-resistant (600 V, 60 to 105 C) |
STO | Standard thermoplastic flexible cord, oil-resistant (600 V, 60 to 105 C) |
STOW | Standard thermoplastic flexible cord, oil-resistant, weather-resistant (600 V, 60 to 105 C) |
STOOW | Standard thermoplastic flexible cord, oil-resistant, weather-resistant (600 V, 60 to 105 C) |
SEOW | Standard elastomer flexible cord, oil-resistant, weather-resistant (600 V, 105 C) |
SEOOW | Standard elastomer flexible cord, oil-resistant, weather-resistant (600 V, 105 C) |
SJEOOW | Junior elastomer flexible cord, oil-resistant, weather-resistant (300 V, 105 C) |
SPT-1 | Parallel thermoplastic lamp cord, insulation class 1 (300 V, 60 to 105 C (UNVERIFIED)) |
SPT-2 | Parallel thermoplastic lamp cord, insulation class 2 (300 V, 60 to 105 C (UNVERIFIED)) |
SPT-3 | Parallel thermoplastic lamp cord, insulation class 3 (300 V, 60 to 105 C (UNVERIFIED)) |
SPT | SPT: parallel thermoplastic (zip) cord, two or three conductors moulded side by side in PVC, no jacket; the insulation class (SPT-1, SPT-2 or SPT-3) not given (300 V; 60 C or 105 C by listing (Southwire, Cerrowire, AWC)) |
SVT | Vacuum-cleaner (service) thermoplastic cord, PVC jacket, 300 V (300 V, 60 to 105 C) |
SVTO | Vacuum-cleaner thermoplastic cord with an oil-resistant PVC jacket, 300 V (300 V, 60 to 105 C) |
HPN | Heater cord, parallel, neoprene (UNVERIFIED expansion) (300 V, 90 C (UNVERIFIED)) |
TYPE W | Portable power cable, 2 kV, tinned copper, EPDM insulation, extra-hard usage (2000 V, 90 C) |
TYPE G | Portable power cable with grounding conductors, 2 kV, mining and industrial (UNVERIFIED) (2000 V, 90 C (UNVERIFIED)) |
G-GC | Portable power cable with grounding and a ground-check conductor (UNVERIFIED) (2000 V, 90 C (UNVERIFIED)) |
DLO | Diesel locomotive cable: tinned flexible copper, EPR insulation, CPE jacket, single conductor (2000 V, 90 C) |
PV WIRE | Photovoltaic wire: stranded copper, XLP insulation, sunlight resistant (600 V or 1000 V or 2000 V, 90 C wet or dry) |
CM | Communications cable, general purpose (300 V, 75 C) |
CMP | Communications cable, plenum rated (low smoke; FEP insulation on 4-pair data cable, low-smoke PVC on 2-conductor cable) (300 V, 60 to 150 C by product (75 C most common)) |
CMR | Communications cable, riser rated (vertical shafts, UL 1666) (300 V, 60 or 75 C by product) |
CMG | Communications cable, general purpose (FT4 vertical flame test) (300 V, 60 C) |
CMX | Communications cable, limited use (residential and in raceway, outdoor-rated types) (300 V, 60 to 75 C) |
CL2 | Class 2 remote-control and signalling cable (Class 2 power-limited, no voltage rating (UL 13 1.2)) |
THERMOSTAT WIRE | Thermostat wire: Class 2 control cable, solid bare copper conductors in a PVC jacket (150 V, Class 2 power-limited (as two makers print it)) |
LANDSCAPE WIRE | Low voltage landscape lighting wire: underground low-energy circuit cable, two stranded copper conductors in one flat PVC layer (150 V (UL), 30 V (CSA LVLL); -20 to 60 C; direct burial) |
CL2R | Class 2 remote-control and signalling cable, riser (Class 2 power-limited, no voltage rating (UL 13 1.2)) |
CL2P | Class 2 remote-control and signalling cable, plenum (Class 2 power-limited, no voltage rating (UL 13 1.2)) |
CL2X | Class 2 remote-control and signalling cable, limited use (Class 2 power-limited, no voltage rating (UL 13 1.2)) |
CL3 | Class 3 remote-control and signalling cable (300 V, Class 3 power-limited (UL 13 1.2: rated 300 V, not so marked)) |
CL3R | Class 3 remote-control and signalling cable, riser (300 V, Class 3 power-limited (UL 13 1.2: rated 300 V, not so marked)) |
CL3P | Class 3 remote-control and signalling cable, plenum (300 V, Class 3 power-limited (UL 13 1.2: rated 300 V, not so marked)) |
CL3X | Class 3 remote-control and signalling cable, limited use (300 V, Class 3 power-limited (UL 13 1.2: rated 300 V, not so marked)) |
FPL | Fire-alarm power-limited cable (300 V, 75 C) |
FPLR | Fire-alarm power-limited cable, riser (UL 1666) (300 V, 75 C) |
FPLP | Fire-alarm power-limited cable, plenum (UL 910, low smoke) (300 V, 75 C) |
OFN | Optical fibre cable, nonconductive general (Dielectric) |
OFNG | Optical fibre cable, nonconductive, general purpose (Dielectric) |
OFNR | Optical fibre cable, nonconductive, riser (Dielectric) |
OFNP | Optical fibre cable, nonconductive, plenum (Dielectric) |
OFC | Optical fibre cable, conductive general (Fibre with metallic strength member) |
OFCR | Optical fibre cable, conductive, riser (Fibre with metallic strength member) |
OFCP | Optical fibre cable, conductive, plenum (Fibre with metallic strength member) |
CAT5E | Category 5e unshielded or shielded twisted-pair data cable, 4 pairs, 24 AWG (up to 100 MHz, 1 Gbit/s) |
CAT6 | Category 6 twisted-pair data cable, 4 pairs, 23 AWG (up to 250 MHz) |
CAT6A | Category 6A augmented twisted-pair data cable, 4 pairs (up to 500 MHz (UNVERIFIED)) |
AWM 1007 | UL AWM style 1007: single-conductor PVC appliance wiring material (hook-up wire) (300 V a.c., 80 C, 32 to 16 AWG) |
AWM 1015 | UL AWM style 1015: single-conductor PVC appliance wiring material (hook-up wire) (600 V a.c. or 750 V d.c., 80 / 90 / 105 C, 30 AWG to 2000 kcmil) |
AWM 2464 | UL AWM style 2464: multi-conductor equipment cable, singles or twisted pairs, often foil and braid screened (300 V a.c., 80 C) |
AWM 2517 | UL AWM style 2517: multi-conductor equipment cable, singles or twisted pairs, often foil and braid screened (300 V a.c., 105 C) |
AWM 2919 | UL AWM style 2919: multi-conductor equipment cable, singles or twisted pairs, often foil and braid screened (30 V a.c., 80 C) |
AWM 20276 | UL AWM style 20276: multi-conductor equipment cable, singles or twisted pairs, often foil and braid screened (30 V a.c., 60 or 80 C) |
VFD | Variable frequency drive cable, Type TC-ER: three XLPE cores, three symmetrical grounds, overall screen (1000 V or 2000 V, 90 C wet and dry) |
TC-ER-JP | Tray cable, exposed run, joist-pull tested (may be pulled through joists in one- and two-family dwellings) (600 V, 90 C dry, 75 C wet) |
CATV | Community antenna television coaxial cable, general use (75 ohm coaxial (RG-6 / RG-59 builds)) |
CATVR | Community antenna television coaxial cable, riser (UL 1666) (75 ohm coaxial (RG-6 / RG-59 builds)) |
CATVP | Community antenna television coaxial cable, plenum (NFPA 262) (75 ohm coaxial (RG-6 / RG-59 builds)) |
CATVX | Community antenna television coaxial cable, limited use (dwellings, raceway) (75 ohm coaxial (RG-6 / RG-59 builds)) |
CMP-LP | Communications cable, plenum rated (low smoke, FEP insulation), limited power (LP): marked with the current per conductor for PoE (300 V, 75 C) |
CMR-LP | Communications cable, riser rated (vertical shafts, UL 1666), limited power (LP): marked with the current per conductor for PoE (300 V, 75 C) |
CMG-LP | Communications cable, general purpose (same listing level as CM), limited power (LP): marked with the current per conductor for PoE (300 V, 60 to 75 C) |
CM-LP | Communications cable, general purpose, limited power (LP): marked with the current per conductor for PoE (300 V, 60 to 75 C) |
OFCG | Optical fibre cable, conductive, general purpose (Fibre with metallic strength member) |
NPLF | Non-power-limited fire alarm cable, general (600 V (typical)) |
NPLFR | Non-power-limited fire alarm cable, riser (600 V (typical)) |
NPLFP | Non-power-limited fire alarm cable, plenum (600 V (typical)) |
ITC-HL | Instrumentation tray cable, shielded pairs, for circuits up to 150 V and 5 A, hazardous location: continuously welded corrugated aluminium sheath and a PVC jacket (300 V) |
PLTC-HL | Power-limited tray cable, shielded pairs, 300 V, hazardous location: continuously welded corrugated aluminium sheath and a PVC jacket (300 V) |
CMUC | Communications under-carpet cable: flat conductors for use under carpet squares (communications) |
SHD-GC | SHD-GC: shielded round portable mine power cable, three EPR phase cores each under a tinned copper / textile braid shield, two grounding conductors and a yellow ground-check conductor, reinforced CPE jacket (2000 V to 35000 V classes, 90 C (Prysmian); 5 kV, 8 kV, 15 kV (Priority Wire)) |
SHD-CGC | SHD-CGC: SHD-GC with an extensible (centre) ground-check conductor and three grounding conductors, 2000 to 5000 V (2000 V and 5000 V, 90 C (Prysmian)) |
MP-GC | MP-GC: mine power feeder cable with ground check, three shielded EPR (or XLP) cores with copper tape shields, two grounding conductors and a ground-check conductor, CPE (or PVC) jacket, 5 to 35 kV, for permanent installation (5000 V to 35000 V, 90 C, 100 % insulation level (Prysmian, Tele-Fonika)) |
ALPETH | ALPETH: aerial telephone cable with an aluminium shield and a polyethylene jacket (telephone) |
ALVYN | ALVYN: indoor riser-rated telephone cable with an aluminium shield and a vinyl (PVC) jacket (telephone) |
ASP | ASP: filled direct-burial telephone cable for rodent areas, corrugated aluminium shield, corrugated steel tape, flooding compound, polyethylene jacket (telephone) |
PIC | PIC: plastic-insulated telephone cable (a general term for any type) (telephone) |