XHHW-2
XHHW-2 is a NEC / UL (USA) cable designation: X = Thermoset (cross-linked polyethylene) insulation; HH = High heat resistant, 90 C; W = Approved for wet locations; -2 = 90 C in both wet and dry locations; XHHW-2 = Thermoset (XLPE) high heat-resistant building wire, 90 C wet or dry. 600 V, 90 C wet and dry. UL 44; NEC Article 310.
2 coding systems recognise this code
Standard, worked reading and related types
Standards behind these values: UL 44 (edition 19): Thermoset-Insulated Wires and Cables. How the values are sourced
Worked reading of XHHW-2 12 AWG, 600 V:
XHHW-2: X = Thermoset (cross-linked polyethylene) insulation; HH = High heat resistant, 90 C; W = Approved for wet locations; -2 = 90 C in both wet and dry locations; XHHW-2 = Thermoset (XLPE) high heat-resistant building wire, 90 C wet or dry. 600 V, 90 C wet and dry. UL 44; NEC Article 31012 AWG, 600 V: one core, copper 12 AWG (3.3 mm²); rated voltage 600 V
Related cable types: XHHW-2-LS · TC (XHHW-2)
NEC / UL (USA)
| Symbol | Meaning |
|---|---|
X | Thermoset (cross-linked polyethylene) insulation |
HH | High heat resistant, 90 C |
W | Approved for wet locations |
-2 | 90 C in both wet and dry locations |
XHHW-2 | Thermoset (XLPE) high heat-resistant building wire, 90 C wet or dry. 600 V, 90 C wet and dry. UL 44; NEC Article 310 |
NEC Article 310 (US building wire, NFPA 70)
| Symbol | Meaning |
|---|---|
X | Cross-Linked Polymer Insulation |
HH | 90°C Insulation |
W | Moisture Resistant |
-2 | With Insulation For Use In Wet Or Dry Locations At Max. Temp. 90°C |
How to read a NEC Article 310 (US building wire, NFPA 70) cable code
What is XHHW-2 cable?
XHHW-2: Thermoset (XLPE) high heat-resistant building wire, 90 C wet or dry. Rating: 600 V, 90 C wet and dry. Standard: UL 44; NEC Article 310.
No outer covering. Copper or aluminium; an "AL" in the text switches the metal. Often dual-marked RW90 in Canada.
Documents and pages the readings were taken from
XHHW-2 dimensions and weight
- XHHW-2 14 AWG 600 V
- XHHW-2 12 AWG 600 V
- XHHW-2 10 AWG 600 V
- XHHW-2 8 AWG 600 V
- XHHW-2 6 AWG 600 V
- XHHW-2 4 AWG 600 V
- XHHW-2 3 AWG 600 V
- XHHW-2 2 AWG 600 V
- XHHW-2 1 AWG 600 V
- XHHW-2 1/0 AWG 600 V
- XHHW-2 2/0 AWG 600 V
- XHHW-2 3/0 AWG 600 V
- XHHW-2 4/0 AWG 600 V
- XHHW-2 250 kcmil 600 V
- XHHW-2 300 kcmil 600 V
- XHHW-2 350 kcmil 600 V
- XHHW-2 400 kcmil 600 V
- XHHW-2 500 kcmil 600 V
- XHHW-2 600 kcmil 600 V
- XHHW-2 700 kcmil 600 V
- XHHW-2 750 kcmil 600 V
- XHHW-2 800 kcmil 600 V
- XHHW-2 900 kcmil 600 V
- XHHW-2 1000 kcmil 600 V
XHHW-2: equivalents in other countries
Shown for 1x3.31 600 V. Each country's rules are applied to this build, keeping the conductor, section, cores, voltage, screen, armour and sheath.
| Country | Standard | Name in that country | Verdict | Differences |
|---|---|---|---|---|
| International (IEC) | IEC 60502 | no letters for this build | Close | Insulation 0.76 → 0.7 mm; Overall diameter 3.79 → 3.67 mm |
Nominal values computed by each standard's rules, not manufacturer data. This is not a statement that two cables are interchangeable: the buyer's specification and the maker's type test decide.
XHHW-2 as the cable designer builds it, 12 AWG, 600 V
Overall diameter 3.8 mm, about 40 kg/km. Nominal values from the standard's tables for this size, computed, not a maker's data.
| Layer | Material | Thickness, mm | Over the layer, mm |
|---|---|---|---|
| Insulation | XLPE | 0.76 | 3.8 |
XHHW-2 on a drum
The smallest drum that passes every check, for 3.8 mm and about 40 kg/km as the cable designer builds it. Drums as their makers print them; lengths are estimates: whole layers wound nested (each turn in the groove of the layer below), wound diameter 1.05 × OD, 50 mm freeboard under the flange rim. Cable makers' own tables print less, as they count aligned layers.
| Length | Drum size (its makers) | Layers | Gross weight |
|---|---|---|---|
| 500 m | NEMA 14x10x5, wood NEMA reels (North America), Okonite | 15 of 18 | 22 kg |
| 1,000 m | NEMA 18x10x6, wood NEMA reels (North America), Okonite | 23 of 29 | 45 kg |
Barrel at least 20 × OD = 76 mm for a cable of this kind (Low voltage, single core): KTG table, the cable's datasheet wins. A load rating is the drum maker's own. A steel drum whose maker prints none is checked against the DIN 46391-4 guide load instead: 28 kN per m³ of gross winding volume.
Other lengths, drums and weights: the cable drum calculator
Load it on a truck: 1000 m on its drum in the loading planner
Laying, sizes and datasheet: XHHW-2
XHHW-2 belongs to the family North American cables: the lowest laying temperature, bending radius, pulling, depth, drum handling and the test after laying, every rule with its sources. Laying and handling guide: North American cables
Its sizes are in AWG and kcmil, which are not the same as the nearest mm²: compare them by area and by resistance. AWG to mm²