SPT-2
SPT-2 is a NEC / UL (USA) cable designation: S = Service cord; P = Parallel (zip) construction; T = Thermoplastic (PVC); -2 = Insulation thickness class 2 (0.045 in on the AWC page); SPT-2 = Parallel thermoplastic lamp cord, insulation class 2. 300 V, 60 to 105 C (UNVERIFIED). UL 62; NEC Table 400.4.
4 coding systems recognise this code
Standard, worked reading and related types
Standards behind these values: IEC 60228:2023 (edition 4.0): Conductors of insulated cables. How the values are sourced
Worked reading of SPT-2 2/C 18 AWG, 300 V:
SPT-2: S = Service cord; P = Parallel (zip) construction; T = Thermoplastic (PVC); -2 = Insulation thickness class 2 (0.045 in on the AWC page); SPT-2 = Parallel thermoplastic lamp cord, insulation class 2. 300 V, 60 to 105 C (UNVERIFIED). UL 62; NEC Table 400.42/C 18 AWG, 300 V: 2 cores, each copper 18 AWG (0.8 mm²); rated voltage 300 V
NEC / UL (USA)
| Symbol | Meaning |
|---|---|
S | Service cord |
P | Parallel (zip) construction |
T | Thermoplastic (PVC) |
-2 | Insulation thickness class 2 (0.045 in on the AWC page) |
SPT-2 | Parallel thermoplastic lamp cord, insulation class 2. 300 V, 60 to 105 C (UNVERIFIED). UL 62; NEC Table 400.4 |
NEC Article 400 (US flexible cords, NFPA 70 / UL 62)
| Symbol | Meaning |
|---|---|
S | Service Cord (Alone: Hard Service Cord, 600 V, Extra Hard Usage) |
P | Parallel Conductor Cord |
T | Thermoplastic Insulation And Jacket |
-2 | Insulation Class 2 (SP-2, SPT-2, SPE-2: 1.14 mm / 0.045 in; NISP-2: 0.76 mm) |
How to read a NEC Article 400 (US flexible cords, NFPA 70 / UL 62) cable code
NEC Article 402 (US fixture wires, NFPA 70)
| Symbol | Meaning |
|---|---|
S | Silicone Rubber |
PT | Extruded Polytetrafluoroethylene (PTFE) Insulation |
-2 | Standard Insulation Thickness, 600 V (Fixture Wire) |
How to read a NEC Article 402 (US fixture wires, NFPA 70) cable code
IEEE 1580
| Symbol | Meaning |
|---|---|
S | Single Conductor Distribution, 2 kcmil |
P | Cross Linked Polyolefin (XLPO) |
T | Polyvinyl Chloride (PVC) |
What is SPT-2 cable?
SPT-2: Parallel thermoplastic lamp cord, insulation class 2. Rating: 300 V, 60 to 105 C (UNVERIFIED). Standard: UL 62; NEC Table 400.4.
Two conductors in zip form, no separate jacket. The -1 / -3 thicknesses and the 60 to 105 C range are not on a fetched page.
Documents and pages the readings were taken from
SPT-2 as the cable designer builds it, 2/C 18 AWG, 300 V
Flat, 6.9 × 3.5 mm (width × thickness), about 40 kg/km. Nominal values from the standard's tables for this size, computed, not a maker's data.
| Layer | Material | Thickness, mm | Over the layer, mm |
|---|---|---|---|
| Insulation | PVC | 1.1 | 3.5 |
SPT-2 on a drum
The smallest drum that passes every check, for 6.9 mm and about 40 kg/km as the cable designer builds it. Drums as their makers print them; lengths are estimates: whole layers wound nested (each turn in the groove of the layer below), wound diameter 1.05 × OD, 50 mm freeboard under the flange rim. Cable makers' own tables print less, as they count aligned layers.
| Length | Drum size (its makers) | Layers | Gross weight |
|---|---|---|---|
| 500 m | NEMA 20x12x10, wood NEMA reels (North America), American Wire Group | 12 of 12 | 30 kg |
| 1,000 m | NEMA 24x18x10, wood NEMA reels (North America), American Wire Group, Okonite | 15 of 20 | 51–54 kg |
Barrel at least 12 × OD = 83 mm for a cable of this kind (Flexible cable (class 5 or 6 conductor)): KTG table, the cable's datasheet wins. A load rating is the drum maker's own. A steel drum whose maker prints none is checked against the DIN 46391-4 guide load instead: 28 kN per m³ of gross winding volume.
Other lengths, drums and weights: the cable drum calculator
Load it on a truck: 1000 m on its drum in the loading planner
Laying, sizes and datasheet: SPT-2
SPT-2 belongs to the family North American cables: the lowest laying temperature, bending radius, pulling, depth, drum handling and the test after laying, every rule with its sources. Laying and handling guide: North American cables
Its sizes are in AWG and kcmil, which are not the same as the nearest mm²: compare them by area and by resistance. AWG to mm²