CMG
CMG is a NEC / UL (USA) cable designation: C = Communications cable; M = Multipurpose rating (reading by usage, UNVERIFIED); G = General purpose (FT4 vertical flame test); CMG = Communications cable, general purpose (FT4 vertical flame test). 300 V, 60 C. UL 444 / CSA C22.2 No. 214; NEC (2026) Article 722.
1 coding system recognises this code
Standard, worked reading and related types
Worked reading of CMG 2/C 18 AWG, 300 V:
CMG: C = Communications cable; M = Multipurpose rating (reading by usage, UNVERIFIED); G = General purpose (FT4 vertical flame test); CMG = Communications cable, general purpose (FT4 vertical flame test). 300 V, 60 C. UL 444 / CSA C22.2 No. 214; NEC (2026) Article 7222/C 18 AWG, 300 V: 2 cores, each copper 18 AWG (0.8 mm²); rated voltage 300 V
NEC / UL (USA)
| Symbol | Meaning |
|---|---|
C | Communications cable |
M | Multipurpose rating (reading by usage, UNVERIFIED) |
G | General purpose (FT4 vertical flame test) |
CMG | Communications cable, general purpose (FT4 vertical flame test). 300 V, 60 C. UL 444 / CSA C22.2 No. 214; NEC (2026) Article 722 |
What is CMG cable?
CMG: Communications cable, general purpose (FT4 vertical flame test). Rating: 300 V, 60 C. Standard: UL 444 / CSA C22.2 No. 214; NEC (2026) Article 722.
UL 444 ed. 6 (2026) 34.3 and Table A1: CMG passes the FT4 / IEEE 1202 vertical flame exposure and is accepted in Canada and the US, seen standard. Two makers print 'CSA CMG (60 C)' beside 'NEC Article 800 Type CM (UL: 75 C)' on the same cable, 300 V (General Cable Carol brand, Remington Industries; checked 2026-11-03, site/burn-e12). UL 444 gives CMG no walls of its own: the designer builds it with the CM walls.
Documents and pages the readings were taken from
Not equivalent, because
IEC 60332-3-24 (cat. C) ≠ FT4 / IEEE 1202 ≠ UL 1685
Not equivalent, because The burner, the flame time and the char limit differ.
IEC 60332-3-24 (cat. C)
- 1.5 litres of non-metallic material per metre on a vertical ladder, 20 min of flame. Sources: IEC 60332-3-24:2000+A1:2008 (edition 1.1, 2009-02), Table A.1 p. 12; cl 5.1 p. 7; cl 5.3 pp. 8-9; Annex A p. 12; Annex B p. 13 (informative); cl 7 (read in the standard)
- Pass: char height at most 2.5 m above the burner. Sources: IEC 60332-3-24:2000+A1:2008 (edition 1.1, 2009-02), Table A.1 p. 12; cl 5.1 p. 7; cl 5.3 pp. 8-9; Annex A p. 12; Annex B p. 13 (informative); cl 7 (read in the standard)
FT4 / IEEE 1202
- A 20 kW burner (70,000 Btu/h) for 20 min. Sources: M. Hirschler, FAA Fire and Materials conference 2001, slides (quoted by others); VTEC Laboratories, cable fire tests (quoted by others)
- Pass: char at most 1.5 m. Sources: M. Hirschler, FAA Fire and Materials conference 2001, slides (quoted by others); VTEC Laboratories, cable fire tests (quoted by others)
UL 1685
- Pass (UL exposure): char below 8 ft (2.44 m). Sources: M. Hirschler, FAA Fire and Materials conference 2001, slides (quoted by others); VTEC Laboratories, cable fire tests (quoted by others)
CMG as the cable designer builds it, 2/C 18 AWG, 300 V
Overall diameter 3.9 mm, about 20 kg/km. Nominal values from the standard's tables for this size, computed, not a maker's data.
| Layer | Material | Thickness, mm | Over the layer, mm |
|---|---|---|---|
| Insulation | PVC | 0.23 | 1.6 |
| Sheath | PVC | 0.33 | 3.9 |
CMG on a drum
The smallest drum that passes every check, for 3.9 mm and about 20 kg/km as the cable designer builds it. Drums as their makers print them; lengths are estimates: whole layers wound nested (each turn in the groove of the layer below), wound diameter 1.05 × OD, 50 mm freeboard under the flange rim. Cable makers' own tables print less, as they count aligned layers.
| Length | Drum size (its makers) | Layers | Gross weight |
|---|---|---|---|
| 500 m | NEMA 14x10x5, wood NEMA reels (North America), Okonite | 15 of 17 | 12 kg |
| 1,000 m | NEMA 18x10x6, wood NEMA reels (North America), Okonite | 23 of 28 | 25 kg |
Barrel at least 15 × OD = 59 mm for a cable of this kind (Low voltage, multi-core): KTG table, the cable's datasheet wins. A load rating is the drum maker's own. A steel drum whose maker prints none is checked against the DIN 46391-4 guide load instead: 28 kN per m³ of gross winding volume.
Other lengths, drums and weights: the cable drum calculator
Load it on a truck: 1000 m on its drum in the loading planner
Laying, sizes and datasheet: CMG
CMG belongs to the family North American cables: the lowest laying temperature, bending radius, pulling, depth, drum handling and the test after laying, every rule with its sources. Laying and handling guide: North American cables
Its sizes are in AWG and kcmil, which are not the same as the nearest mm²: compare them by area and by resistance. AWG to mm²