CM
CM is a NEC / UL (USA) cable designation: C = Communications cable; M = Multipurpose rating (reading by usage, UNVERIFIED); CM = Communications cable, general purpose. 300 V, 75 C. UL 444; NEC (2026) Article 722.
2 coding systems recognise this code
Standard, worked reading and related types
Worked reading of CM 2/C 18 AWG, 300 V:
CM: C = Communications cable; M = Multipurpose rating (reading by usage, UNVERIFIED); CM = Communications cable, general purpose. 300 V, 75 C. UL 444; NEC (2026) Article 7222/C 18 AWG, 300 V: 2 cores, each copper 18 AWG (0.8 mm²); rated voltage 300 V
NEC / UL (USA)
| Symbol | Meaning |
|---|---|
C | Communications cable |
M | Multipurpose rating (reading by usage, UNVERIFIED) |
CM | Communications cable, general purpose. 300 V, 75 C. UL 444; NEC (2026) Article 722 |
Norwegian type designation (NEK 606 offshore and Norwegian land cables)
| Symbol | Meaning |
|---|---|
C | Polychloroprene (Neoprene - PCP), Or Chlorinated Polyethylene (CPE) |
M | Polyester |
How to read a Norwegian type designation (NEK 606 offshore and Norwegian land cables) cable code
What is CM cable?
CM: Communications cable, general purpose. Rating: 300 V, 75 C. Standard: UL 444; NEC (2026) Article 722.
Hierarchy: CMP over CMR over CM (ECM article). 75 C is the UL listing temperature two makers print for NEC Article 800 Type CM (General Cable Carol brand, Remington Industries; Belden prints 75 C too); 300 V at both (checked 2026-11-03, site/burn-e12). The cable's own range (-20 to 80 C at both) is wider than the listing.
Documents and pages the readings were taken from
CM as the cable designer builds it, 2/C 18 AWG, 300 V
Overall diameter 3.9 mm, about 20 kg/km. Nominal values from the standard's tables for this size, computed, not a maker's data.
| Layer | Material | Thickness, mm | Over the layer, mm |
|---|---|---|---|
| Insulation | PVC | 0.23 | 1.6 |
| Sheath | PVC | 0.33 | 3.9 |
CM on a drum
The smallest drum that passes every check, for 3.9 mm and about 20 kg/km as the cable designer builds it. Drums as their makers print them; lengths are estimates: whole layers wound nested (each turn in the groove of the layer below), wound diameter 1.05 × OD, 50 mm freeboard under the flange rim. Cable makers' own tables print less, as they count aligned layers.
| Length | Drum size (its makers) | Layers | Gross weight |
|---|---|---|---|
| 500 m | NEMA 14x10x5, wood NEMA reels (North America), Okonite | 15 of 17 | 12 kg |
| 1,000 m | NEMA 18x10x6, wood NEMA reels (North America), Okonite | 23 of 28 | 25 kg |
Barrel at least 15 × OD = 59 mm for a cable of this kind (Low voltage, multi-core): KTG table, the cable's datasheet wins. A load rating is the drum maker's own. A steel drum whose maker prints none is checked against the DIN 46391-4 guide load instead: 28 kN per m³ of gross winding volume.
Other lengths, drums and weights: the cable drum calculator
Load it on a truck: 1000 m on its drum in the loading planner
Laying, sizes and datasheet: CM
CM belongs to the family North American cables: the lowest laying temperature, bending radius, pulling, depth, drum handling and the test after laying, every rule with its sources. Laying and handling guide: North American cables
Its sizes are in AWG and kcmil, which are not the same as the nearest mm²: compare them by area and by resistance. AWG to mm²
Selling this cable? Open it in the designer and get a datasheet with your logo (Pro). Open the cable designer · See Pro
Work with CM
Who makes or stocks this cable?