CM

CM is a NEC / UL (USA) cable designation: C = Communications cable; M = Multipurpose rating (reading by usage, UNVERIFIED); CM = Communications cable, general purpose. 300 V, 75 C. UL 444; NEC (2026) Article 722.

2 coding systems recognise this code

Standard, worked reading and related types

Worked reading of CM 2/C 18 AWG, 300 V:

  • CM: C = Communications cable; M = Multipurpose rating (reading by usage, UNVERIFIED); CM = Communications cable, general purpose. 300 V, 75 C. UL 444; NEC (2026) Article 722
  • 2/C 18 AWG, 300 V: 2 cores, each copper 18 AWG (0.8 mm²); rated voltage 300 V

Related cable types: CMP · CMR · CMG · CMX · VCm · CM-LP

NEC / UL (USA)

SymbolMeaning
CCommunications cable
MMultipurpose rating (reading by usage, UNVERIFIED)
CMCommunications cable, general purpose. 300 V, 75 C. UL 444; NEC (2026) Article 722

Norwegian type designation (NEK 606 offshore and Norwegian land cables)

SymbolMeaning
CPolychloroprene (Neoprene - PCP), Or Chlorinated Polyethylene (CPE)
MPolyester

How to read a Norwegian type designation (NEK 606 offshore and Norwegian land cables) cable code

What is CM cable?

CM: Communications cable, general purpose. Rating: 300 V, 75 C. Standard: UL 444; NEC (2026) Article 722.

Hierarchy: CMP over CMR over CM (ECM article). 75 C is the UL listing temperature two makers print for NEC Article 800 Type CM (General Cable Carol brand, Remington Industries; Belden prints 75 C too); 300 V at both (checked 2026-11-03, site/burn-e12). The cable's own range (-20 to 80 C at both) is wider than the listing.

Documents and pages the readings were taken from

NEC / UL (USA): how to read the cable type names

CM as the cable designer builds it, 2/C 18 AWG, 300 V

Overall diameter 3.9 mm, about 20 kg/km. Nominal values from the standard's tables for this size, computed, not a maker's data.

LayerMaterialThickness, mmOver the layer, mm
InsulationPVC0.231.6
SheathPVC0.333.9

CM on a drum

The smallest drum that passes every check, for 3.9 mm and about 20 kg/km as the cable designer builds it. Drums as their makers print them; lengths are estimates: whole layers wound nested (each turn in the groove of the layer below), wound diameter 1.05 × OD, 50 mm freeboard under the flange rim. Cable makers' own tables print less, as they count aligned layers.

LengthDrum size (its makers)LayersGross weight
500 mNEMA 14x10x5, wood NEMA reels (North America), Okonite15 of 1712 kg
1,000 mNEMA 18x10x6, wood NEMA reels (North America), Okonite23 of 2825 kg

Barrel at least 15 × OD = 59 mm for a cable of this kind (Low voltage, multi-core): KTG table, the cable's datasheet wins. A load rating is the drum maker's own. A steel drum whose maker prints none is checked against the DIN 46391-4 guide load instead: 28 kN per m³ of gross winding volume.

Other lengths, drums and weights: the cable drum calculator

Load it on a truck: 1000 m on its drum in the loading planner

Laying, sizes and datasheet: CM

CM belongs to the family North American cables: the lowest laying temperature, bending radius, pulling, depth, drum handling and the test after laying, every rule with its sources. Laying and handling guide: North American cables

Its sizes are in AWG and kcmil, which are not the same as the nearest mm²: compare them by area and by resistance. AWG to mm²

Selling this cable? Open it in the designer and get a datasheet with your logo (Pro). Open the cable designer · See Pro

Work with CM

Who makes or stocks this cable?

Makers and stockists of this cable family appear here as sponsors for your region, each marked "Sponsored"; a listing never changes what this page says about the cable.