SVTO

SVTO is a NEC / UL (USA) cable designation: SVT = Service vacuum thermoplastic cord; O = Oil-resistant jacket; SVTO = Vacuum-cleaner thermoplastic cord with an oil-resistant PVC jacket, 300 V. 300 V, 60 to 105 C. UL 62; NEC Table 400.4.

5 coding systems recognise this code

Standard, worked reading and related types

Worked reading of SVTO:

  • SVTO: SVT = Service vacuum thermoplastic cord; O = Oil-resistant jacket; SVTO = Vacuum-cleaner thermoplastic cord with an oil-resistant PVC jacket, 300 V. 300 V, 60 to 105 C. UL 62; NEC Table 400.4

Related cable types: SJTO · STO · SVT

NEC / UL (USA)

SymbolMeaning
SVTService vacuum thermoplastic cord
OOil-resistant jacket
SVTOVacuum-cleaner thermoplastic cord with an oil-resistant PVC jacket, 300 V. 300 V, 60 to 105 C. UL 62; NEC Table 400.4

UTE (France, NF C 30-202 traditional system)

SymbolMeaning
SFlexible Cable
VPolyvinyl Chloride (PVC)
TTextile Braiding Over Twisted Cores
ONo Filler

How to read a UTE (France, NF C 30-202 traditional system) cable code

NEC Article 400 (US flexible cords, NFPA 70 / UL 62)

SymbolMeaning
SVVacuum Cleaner Cord (Service Vacuum, 300 V, Not Hard Usage)
TThermoplastic Insulation And Jacket
OOil Resistant Sheath

How to read a NEC Article 400 (US flexible cords, NFPA 70 / UL 62) cable code

NBN (Belgian national cable names, ...B types)

SymbolMeaning
SSignal Cable
VPolyvinyl Chloride (PVC)
TTransportable (Moving Installation, For Mobile Appliances)
OOrdinary Insulation, Installation Wire (750 V)

How to read a NBN (Belgian national cable names, ...B types) cable code

NEN 3207 / KEMA (Netherlands)

SymbolMeaning
SSilicone Rubber
VPolyvinyl Chloride (PVC)
TFibrous (Textile) Covering
OOval Conductor

How to read a NEN 3207 / KEMA (Netherlands) cable code

What is SVTO cable?

SVTO: Vacuum-cleaner thermoplastic cord with an oil-resistant PVC jacket, 300 V. Rating: 300 V, 60 to 105 C. Standard: UL 62; NEC Table 400.4.

Letters read from SVT plus the O of Table 400.4; no fetched page lists SVTO itself (UNVERIFIED).

Documents and pages the readings were taken from

NEC / UL (USA): how to read the cable type names

Fire behaviour (EU CPR)

A CPR class is declared by the maker in its Declaration of Performance and printed on the sheath (EN 50575 cl 7). This decoder does not assign one. What the CPR classes mean →

Sources: EN 13501-6 draft and FprEN 50575:2014 final draft (drafts, not the published texts); IEC 60332-3-24:2000+A1:2008; EN 13501-3 draft A2.

Laying, sizes and datasheet: SVTO

Its sizes are in AWG and kcmil, which are not the same as the nearest mm²: compare them by area and by resistance. AWG to mm²

Work with SVTO

Who makes or stocks this cable?

Makers and stockists of this cable family appear here as sponsors for your region, each marked "Sponsored"; a listing never changes what this page says about the cable.

Related cables

More NEC / UL (USA) designations

SVTO