NEN 3207 / KEMA (Netherlands)

Netherlands · 96 symbols · How to read a NEN 3207 / KEMA (Netherlands) cable code

svSector Shaped Conductor
fFine-Wired In Flexible Cables-Class 5
ffUltra Fine-Wired In Flexible Cables-Class 6
oOval Conductor
VPolyvinyl Chloride (PVC)
V4Cross Linked PVC
EPolyethylene (PE)
YCross-Linked Polyethylene (XLPE)
ZLow Smoke Cross Linked Compound
Z1Low Smoke Zero Halogen Compound
BEthylene-Propylene Rubber (EPR)
GEthylene Vinylacetate (EVA)
CChloroprene Rubber
QPolyurethane (PUR)
SSilicone Rubber
oOil Resistant
mbFlame Retardant
L-Lead Sheath
PPaper Insulation
pFlat Cable
TSTwin Cable
FSFlat Tinsel Cord
XCross-Linked Polyethylene (XLPE)
cConcentric Conductor (Screen)
fbCircuit Integrity (Resistance To Fire)
JGlass Fibre
TFibrous (Textile) Covering
P-Rigid Metal Pipe (Non-Flexible Metal Sheath)
S-Metallic Foil/Wire Screen
G-Armoured (Round Or Flat Steel Wire, Or Steel Tape)
zhHalogen Free
asWith Earthing Screen
afWith Shielding (Screen), Earth Shield
MbKEthylenepropylene Rubber (EPR) Sheathed Cable
MeKPolyethylene (PE) Sheathed Cable
MgKEthylene Vinylacetate (EVA) Sheathed Cable
MhKChlorinated Or Chlorosulphonated Polyethylene (CPE / CSM) Sheathed Cable
MqKPolyurethane Sheathed Cable
MrKRubber Sheathed Cable
MsKSilicone Sheathed Cable
MvKPVC Sheathed Cable
Mv4KCross Linked PVC Sheathed Cable
MzKLow Smoke Cross Linked Sheathed Cable
Mz1KLow Smoke Zero Halogen (LS0H) Sheathed Cable
MbSEthylenepropylene Rubber (EPR) Sheathed Cord
MeSPolyethylene (PE) Sheathed Cord
MgSEthylene Vinylacetate (EVA) Sheathed Cord
MhSChlorinated Or Chlorosulphonated Polyethylene (CPE / CSM) Sheathed Cord
MqSPolyurethane Sheathed Cord
MrSRubber Sheathed Cord
MsSSilicone Sheathed Cord
MvSPVC Sheathed Cord
Mv4SCross Linked PVC Sheathed Cord
MzSLow Smoke Cross Linked Sheathed Cord
Mz1SLow Smoke Zero Halogen (LS0H) Sheathed Cord
MbLEthylenepropylene Rubber (EPR) Sheathed Conductor
MeLPolyethylene (PE) Sheathed Line (Mantelleiding)
MgLEthylene Vinylacetate (EVA) Sheathed Conductor
MhLChlorinated Or Chlorosulphonated Polyethylene (CPE / CSM) Sheathed Line (Mantelleiding)
MqLPolyurethane Sheathed Conductor
MrLRubber Sheathed Conductor
MsLSilicone Sheathed Conductor
MvLPVC Sheathed Conductor
Mv4LCross Linked PVC Sheathed Conductor
MzLLow Smoke Cross Linked Sheathed Conductor
Mz1LLow Smoke Zero Halogen (LS0H) Sheathed Line (Mantelleiding)
MKCable With Non-Metallic Sheath And Mechanical Protection, No Inner Sheath
AKAluminum Sheathed Cable
KKCopper Sheathed Cable
htWith Centre Element (Met Hart)
zHeavy Sheath Or Heavy Construction
zzExtra Heavy Sheath Or Extra Heavy Construction
aWith Uninsulated (Bare) Protective Conductor (Older Text: Bare Cable Shield)
rRound Conductor
ssStranded With More Wires Than s, Multi Fine Wires, Class 2 (Older Text: Highly Flexible)
cPolychloroprene Sheath, Vulcanised
hWith Auxiliary Conductor(s)
sasWith S-Shaped (Meandering) Copper Earthing Screen, Wave-Formed Concentric Copper Conductor
RVulcanised Rubber (Natural, SBR Or EPR, 60 °C)
lqwdLongitudinally And Quasi-Radially Water-Tight
AlAluminium Conductor (No Letter: Copper)
MDWiring Wire (Montagedraad)
O-Braid (Braid Armour)
LKLead-Sheathed Cable
gvWith Integrated Optical Fibre(s)
ewWith Parallel Cores (Evenwijdige Aders)
mSolid Conductor (Massief, Class 1)
sStranded Conductor (Samengeslagen, Class 2)
lwdLongitudinally Watertight
dlwdTransversely (Radially) And Longitudinally Watertight
dwdTransversely (Radially) Watertight
HChlorinated Or Chlorosulphonated Polyethylene (CPE / CSM)
scWith S-Shaped (Wave-Form) Concentric Conductor
DInstallation Wire (*D: Insulation Letter In Front, e.g. VD)
rvWith Radial Field (Individually Screened Cores, MV)
P1Polypropylene Thermoplastic Elastomer (PP-TPE) Insulation

Cable designations read in this system