SHD-GC

SHD-GC is a NEC / UL (USA) cable designation: SHD = Shielded, heavy duty: each phase core under a flexible copper braid shield (Prysmian: Shielded Round); GC = Ground-check conductor, yellow polypropylene insulated, for fail-safe ground monitoring; SHD-GC = SHD-GC: shielded round portable mine power cable, three EPR phase cores each under a tinned copper / textile braid shield, two grounding conductors and a yellow ground-check conductor, reinforced CPE jacket. 2000 V to 35000 V classes, 90 C (Prysmian); 5 kV, 8 kV, 15 kV (Priority Wire). ICEA S-75-381 / NEMA WC 58; MSHA accepted.

1 coding system recognises this code

NEC / UL (USA)

SymbolMeaning
SHDShielded, heavy duty: each phase core under a flexible copper braid shield (Prysmian: Shielded Round)
GCGround-check conductor, yellow polypropylene insulated, for fail-safe ground monitoring
SHD-GCSHD-GC: shielded round portable mine power cable, three EPR phase cores each under a tinned copper / textile braid shield, two grounding conductors and a yellow ground-check conductor, reinforced CPE jacket. 2000 V to 35000 V classes, 90 C (Prysmian); 5 kV, 8 kV, 15 kV (Priority Wire). ICEA S-75-381 / NEMA WC 58; MSHA accepted

What is SHD-GC cable?

SHD-GC: shielded round portable mine power cable, three EPR phase cores each under a tinned copper / textile braid shield, two grounding conductors and a yellow ground-check conductor, reinforced CPE jacket. Rating: 2000 V to 35000 V classes, 90 C (Prysmian); 5 kV, 8 kV, 15 kV (Priority Wire). Standard: ICEA S-75-381 / NEMA WC 58; MSHA accepted.

Prysmian NA mining catalogue p.9 and p.11: 'Anaconda Type SHD-GC Shielded Round w/Ground-Check 2000 Volts / 5000 Volts, 90 C, Three Conductor': coated copper rope-lay strands (ASTM B172), EPR, extruded strand shield from 5 kV, 'A flexible coated copper/textile braid shield ... colored textile braid in black, blue, and red', ground-check conductor 'insulated with high-strength yellow polypropylene', two grounding conductors in contact with the braid, 'Reinforced, two-layer, extra-heavy-duty, lead-cured Chlorinated Polyethylene (CPE)' jacket, jacket marking '3/C TYPE SHD-GC 5000 VOLTS ... MSHA'. Tele-Fonika 2008: SHD-GC to ICEA S-75-381 / WC 58 and CSA C22.2 No. 96, up to 2, 5, 8 kV. The letters SHD are not expanded in the sources read; 'shielded' is the makers' word.

Documents and pages the readings were taken from

NEC / UL (USA): how to read the cable type names

Laying, sizes and datasheet: SHD-GC

Its sizes are in AWG and kcmil, which are not the same as the nearest mm²: compare them by area and by resistance. AWG to mm²

Work with SHD-GC

Who makes or stocks this cable?

Makers and stockists of this cable family appear here as sponsors for your region, each marked "Sponsored"; a listing never changes what this page says about the cable.