DIN VDE 0250 cords, control and special cables (Germany)

Germany · 92 symbols · How to read a DIN VDE 0250 cords, control and special cables (Germany) cable code

NVDE Standard
(N)Similar To VDE Standard
XSimilar To VDE Standard
LiEquipment Wire With Fine Stranded Conductor
LiFEquipment Wire With Ultra Fine Stranded Conductor
ECopper Drain / Earth Wire
kCold Resistant
MSheathed Installation Cable, Medium Mechanical Stress (Mantelleitung, E.g. NYM)
XCross Linked Thermoplastics
2YPolyethylene (PE)
5YPolytetrafluoroethylene (PTFE, Teflon)
5YXPerfluoroalkoxy (PFA)
7YEthylene Tetrafluoroethylene (ETFE)
9YPolypropylene (PP)
CShielded
CGEConductive Non-Metallic Layer Over The Insulation Of Each Phase Core
SBraiding Of Galvanised Steel Wires
-OWithout Earthing Core (No Green/Yellow Core)
-JWith Earthing Core (Green/Yellow Core)
-JZWith Green/Yellow Earth Core, Other Cores Numbered (White Numbers On Black)
-OZWithout Green/Yellow Earth Core, All Cores Numbered (White Numbers On Black)
3GEthylene-Propylene Rubber (EPR)
4GEthylene Vinylacetate (EVA)
5GChloroprene Rubber
6GChlorosulphonated Polyethylene (CSM)
53GChlorinated Polyethylene (CPE)
8GNitril-Rubber
11YPolyurethane (PUR)
PURPolyurethane (PUR)
3YPolystyrene (PS)
4YPolyamide (PA)
10YPolyvinylidene Fluoride
2GSilicone Rubber
O2YCellular (Foamed) Polyethylene
02YSFoam-Skin Polyethylene (Cellular PE With A Solid PE Skin)
O2YSFoam-Skin Polyethylene (Cellular PE With A Solid PE Skin)
YvReinforced Polyvinylchloride Sheath
2YvReinforced Polyethylene Sheath
öOil Resistant
TSupport / Reinforcement Element (Tragorgan, E.g. Crane Cable NSHTÖU)
uFlame Retardant
BLead Sheath
ASingle-Core Non-Sheathed Cable
DSolid Wire
AFSingle-Core Non-Sheathed Cable, Fine-Wired
FFlexible (Fine-Stranded Conductor, As In SiHF, SiF) Or Flexible Luminaire Wire
LFluorescent-Tube Cable
LHConnecting Cable, Light Mechanical Load
MHConnecting Cable, Moderate Mechanical Load
SHConnecting Cable, Severe Mechanical Load
SSHConnecting Cable, Special Load
SLControl Cable/Welding Cable
SControl Cable
LSLightweight Control Cable
HSHigh Voltage Cable
TSTrailing Cable
TMTrailing Cable, Moderate Mechanical Load
FLFlat Cable
SiSilicone Cable
ZTwin Cable
GLGlass Fibre
RDFlexible Round Cable
F-Cable for Fixed Installation
R-Cable for Reeling
ÜLMonitoring Conductor
-ZNumbered Cores
VWiring Cable (Verdrahtungsleitung); (V) In Mining Cables: Reinforced
OEOil Resistant
-BCore Colours acc. VDE 0293 (HD308)
-JBWith Green/Yellow Earth Core, Other Core Colours To VDE 0293 (HD 308)
-OBWithout Earthing Core (No G/Y) - All Core Colours acc. VDE 0293 (HD308)
DScreen As Copper Wire Serving
PPolyurethane (PUR) Sheath
GRubber / Elastomer Insulation Or Sheath (Older Editions: Natural Rubber NR Or SBR)
wHeat Resistant And Weather Resistant
SSpecial Design (Sonder-), E.g. Special Rubber-Insulated Single Core
SHT1 kV Reeling Cable (Mining)
CGConductive Non-Metallic Layer Over The Laid-Up Cores (Or Between Inner And Outer Sheath)
CEMetallic Screen Over The Insulation Of Each Phase Core
KONConcentric Protective Or Monitoring Conductor Between Inner And Outer Sheath
UELMonitoring Conductor (International Spelling Of ÜL)
LLightweight Design (Mining And Trailing Cables, Prysmian Key)
YPolyvinyl Chloride (PVC); Control-Cable Key: Thermoplastics In General
6YFluorinated Ethylene Propylene (FEP)
CGCSemiconductive Conductor Screen Plus Metallic Screen Over The Insulation Screen
HXCross-Linked Halogen-Free Polymer Compound
7GFluorinated Rubber (FKM)
12YPolyester: Polyethylene Terephthalate (PETP) Or Thermoplastic Polyester Elastomer (TPE-E)
02YCellular (Foamed) Polyethylene
vReinforced Sheath (As In Yv, 2Yv); Leitungen Block Also: Torsion-Proof
FEInsulation Integrity In Fire (Isolationserhalt) For The Time Written After It, E.g. FE180 = 180 Min
HHalogen-Free Compound (Insulation Or Sheath)

Cable designations read in this system