XH

XH is a DIN VDE 0250 cords, control and special cables (Germany) cable designation: X = Similar To VDE Standard; H = Halogen-Free Compound (Insulation Or Sheath).

7 coding systems recognise this code

Standard, worked reading and related types

Worked reading of XH:

  • XH: X = Similar To VDE Standard; H = Halogen-Free Compound (Insulation Or Sheath)

Related cable types: XHH · N2XH · NHXH · XHIV · NA2XH · N2XH-J

DIN VDE 0250 cords, control and special cables (Germany)

SymbolMeaning
XSimilar To VDE Standard
HHalogen-Free Compound (Insulation Or Sheath)

How to read a DIN VDE 0250 cords, control and special cables (Germany) cable code

NEC Article 310 (US building wire, NFPA 70)

SymbolMeaning
XCross-Linked Polymer Insulation
H75°C Insulation

How to read a NEC Article 310 (US building wire, NFPA 70) cable code

NEC Article 402 (US fixture wires, NFPA 70)

SymbolMeaning
XCross-Linked Polyolefin Insulation
H75°C Heat-Resistant Insulation (After R Or FF); ECTFE Insulation (First Letter, HF / HFF)

How to read a NEC Article 402 (US fixture wires, NFPA 70) cable code

Norwegian type designation (NEK 606 offshore and Norwegian land cables)

SymbolMeaning
XNo Insulation
HChlorosulphonated Polyethylene (CSP) (Nexans key: or CPE)

How to read a Norwegian type designation (NEK 606 offshore and Norwegian land cables) cable code

NBN (Belgian national cable names, ...B types)

SymbolMeaning
XCross-Linked Polyethylene (XLPE)
HResistant To Humidity

How to read a NBN (Belgian national cable names, ...B types) cable code

ZN-TF-500 (Poland, MV cables)

SymbolMeaning
XPolyethylene (PE) Sheath
HCable With Radial Field (Screened Cores, Medium Voltage)

How to read a ZN-TF-500 (Poland, MV cables) cable code

Swiss cable codes (ASE/SEV wire codes and power cable codes)

SymbolMeaning
XCross-Linked Polyethylene (XLPE)
HCable With Radial Electric Field (Höchstädter Type)

How to read a Swiss cable codes (ASE/SEV wire codes and power cable codes) cable code

How to read a DIN VDE 0250 cords, control and special cables (Germany) cable code

A DIN VDE 0250 cords, control and special cables (Germany) designation (Germany) is a row of letter groups, and each group stands for one part of the cable: conductor, insulation, screen, armour, sheath, or the standard it follows. The decoder knows 92 symbols for this system.

What does X mean in a DIN VDE 0250 cords, control and special cables (Germany) cable code? X means Similar To VDE Standard; or Cross Linked Thermoplastics.

What does H mean in a DIN VDE 0250 cords, control and special cables (Germany) cable code? H means Halogen-Free Compound (Insulation Or Sheath).

Fire behaviour (EU CPR)

  • Halogen-free compound (H). Under the CPR this shows in the additional classes: acidity a1 to a3 (EN 60754-2) and smoke s1 to s3 (EN 50399; s1a and s1b add the 3 m cube test EN 61034-2). The main class, Aca to Fca, depends on the whole construction.

    Typically targeted, as declared by makers for this kind of construction in the examples this site checked (not the class of this cable):

    Listed as sources, alphabetically by maker. No maker pays to appear here.

A CPR class is declared by the maker in its Declaration of Performance and printed on the sheath (EN 50575 cl 7). This decoder does not assign one. What the CPR classes mean →

Sources: EN 13501-6 draft and FprEN 50575:2014 final draft (drafts, not the published texts); IEC 60332-3-24:2000+A1:2008; EN 13501-3 draft A2.

Laying, sizes and datasheet: XH

Its sizes are in AWG and kcmil, which are not the same as the nearest mm²: compare them by area and by resistance. AWG to mm²

Work with XH

Who makes or stocks this cable?

Makers and stockists of this cable family appear here as sponsors for your region, each marked "Sponsored"; a listing never changes what this page says about the cable.

Related cables

More DIN VDE 0250 cords, control and special cables (Germany) designations

XH