LIYY-J

LIYY-J is a DIN VDE 0250 cords, control and special cables (Germany) cable designation: Li = Equipment Wire With Fine Stranded Conductor; Y = Polyvinyl Chloride (PVC); Control-Cable Key: Thermoplastics In General; Y = Polyvinyl Chloride (PVC); Control-Cable Key: Thermoplastics In General; -J = With Earthing Core (Green/Yellow Core).

1 coding system recognises this code

Standard, worked reading and related types

Worked reading of LIYY-J:

  • LIYY-J: Li = Equipment Wire With Fine Stranded Conductor; Y = Polyvinyl Chloride (PVC); Control-Cable Key: Thermoplastics In General; Y = Polyvinyl Chloride (PVC); Control-Cable Key: Thermoplastics In General; -J = With Earthing Core (Green/Yellow Core)

Related cable types: LIYY

DIN VDE 0250 cords, control and special cables (Germany)

SymbolMeaning
LiEquipment Wire With Fine Stranded Conductor
YPolyvinyl Chloride (PVC); Control-Cable Key: Thermoplastics In General
YPolyvinyl Chloride (PVC); Control-Cable Key: Thermoplastics In General
-JWith Earthing Core (Green/Yellow Core)

How to read a DIN VDE 0250 cords, control and special cables (Germany) cable code

How to read a DIN VDE 0250 cords, control and special cables (Germany) cable code

A DIN VDE 0250 cords, control and special cables (Germany) designation (Germany) is a row of letter groups, and each group stands for one part of the cable: conductor, insulation, screen, armour, sheath, or the standard it follows. The decoder knows 92 symbols for this system.

What does Li mean in a DIN VDE 0250 cords, control and special cables (Germany) cable code? Li means Equipment Wire With Fine Stranded Conductor.

What does Y mean in a DIN VDE 0250 cords, control and special cables (Germany) cable code? Y means Polyvinyl Chloride (PVC); Control-Cable Key: Thermoplastics In General.

What does -J mean in a DIN VDE 0250 cords, control and special cables (Germany) cable code? -J means With Earthing Core (Green/Yellow Core).

Fire behaviour (EU CPR)

A CPR class is declared by the maker in its Declaration of Performance and printed on the sheath (EN 50575 cl 7). This decoder does not assign one. What the CPR classes mean →

Sources: EN 13501-6 draft and FprEN 50575:2014 final draft (drafts, not the published texts); IEC 60332-3-24:2000+A1:2008; EN 13501-3 draft A2.