NXH

NXH is a DIN VDE 0250 cords, control and special cables (Germany) cable designation: N = VDE Standard; X = Cross Linked Thermoplastics; H = Halogen-Free Compound (Insulation Or Sheath).

6 coding systems recognise this code

Standard, worked reading and related types

Standards behind these values: IEC 60502-1:2004 (edition 2.0): Power cables with extruded insulation and their accessories for rated voltages from 1 kV (Um = 1,2 kV) up to 30 kV (Um = 36 kV) - Part 1: Cables for rated voltages of 1 kV (Um = 1,2 kV) and 3 kV (Um = 3,6 kV); IEC 60228:2023 (edition 4.0): Conductors of insulated cables. How the values are sourced

Worked reading of NXH 1x16 0.6/1 kV:

  • NXH: N = VDE Standard; X = Cross Linked Thermoplastics; H = Halogen-Free Compound (Insulation Or Sheath)
  • 1x16 0.6/1 kV: one core, copper 16 mm²; rated voltage 0.6/1 kV

Related cable types: nxhh · N2XH · NHXH · NXMH · Nh · XH

DIN VDE 0250 cords, control and special cables (Germany)

SymbolMeaning
NVDE Standard
XCross Linked Thermoplastics
HHalogen-Free Compound (Insulation Or Sheath)

How to read a DIN VDE 0250 cords, control and special cables (Germany) cable code

China (GB / JB/T / MT cable model codes)

SymbolMeaning
NNylon Jacket
XNatural Or Styrene-Butadiene Rubber
HRubber Sheath; Chlorosulphonated Polyethylene (CSM) Sheath In Marine Cables

How to read a China (GB / JB/T / MT cable model codes) cable code

NEC Article 310 (US building wire, NFPA 70)

SymbolMeaning
NNylon Jacket
XCross-Linked Polymer Insulation
H75°C Insulation

How to read a NEC Article 310 (US building wire, NFPA 70) cable code

NEC Article 402 (US fixture wires, NFPA 70)

SymbolMeaning
NNylon Jacket
XCross-Linked Polyolefin Insulation
H75°C Heat-Resistant Insulation (After R Or FF); ECTFE Insulation (First Letter, HF / HFF)

How to read a NEC Article 402 (US fixture wires, NFPA 70) cable code

ZN-TF-500 (Poland, MV cables)

SymbolMeaning
NLow Smoke Zero Halogen Compound
XPolyethylene (PE) Sheath
HCable With Radial Field (Screened Cores, Medium Voltage)

How to read a ZN-TF-500 (Poland, MV cables) cable code

Swiss cable codes (ASE/SEV wire codes and power cable codes)

SymbolMeaning
NHalogen-Free Thermoplastic Sheath (PE Only)
XCross-Linked Polyethylene (XLPE)
HCable With Radial Electric Field (Höchstädter Type)

How to read a Swiss cable codes (ASE/SEV wire codes and power cable codes) cable code

How to read a DIN VDE 0250 cords, control and special cables (Germany) cable code

A DIN VDE 0250 cords, control and special cables (Germany) designation (Germany) is a row of letter groups, and each group stands for one part of the cable: conductor, insulation, screen, armour, sheath, or the standard it follows. The decoder knows 92 symbols for this system.

What does N mean in a DIN VDE 0250 cords, control and special cables (Germany) cable code? N means VDE Standard.

What does X mean in a DIN VDE 0250 cords, control and special cables (Germany) cable code? X means Similar To VDE Standard; or Cross Linked Thermoplastics.

What does H mean in a DIN VDE 0250 cords, control and special cables (Germany) cable code? H means Halogen-Free Compound (Insulation Or Sheath).

Fire behaviour (EU CPR)

  • Halogen-free compound (H). Under the CPR this shows in the additional classes: acidity a1 to a3 (EN 60754-2) and smoke s1 to s3 (EN 50399; s1a and s1b add the 3 m cube test EN 61034-2). The main class, Aca to Fca, depends on the whole construction.

    Typically targeted, as declared by makers for this kind of construction in the examples this site checked (not the class of this cable):

    Listed as sources, alphabetically by maker. No maker pays to appear here.

A CPR class is declared by the maker in its Declaration of Performance and printed on the sheath (EN 50575 cl 7). This decoder does not assign one. What the CPR classes mean →

Sources: EN 13501-6 draft and FprEN 50575:2014 final draft (drafts, not the published texts); IEC 60332-3-24:2000+A1:2008; EN 13501-3 draft A2.

NXH as the cable designer builds it, 1x16 0.6/1 kV

Overall diameter 9.1 mm, about 210 kg/km. Nominal values from the standard's tables for this size, computed, not a maker's data.

LayerMaterialThickness, mmOver the layer, mm
InsulationXLPE0.706.3
SheathHalogen-free (LSZH)1.49.1

NXH on a drum

The smallest drum that passes every check, for 9.1 mm and about 210 kg/km as the cable designer builds it. Drums as their makers print them; lengths are estimates: whole layers wound nested (each turn in the groove of the layer below), wound diameter 1.05 × OD, 50 mm freeboard under the flange rim. Cable makers' own tables print less, as they count aligned layers.

LengthDrum size (its makers)LayersGross weight
500 mKTG 6 (600 mm flange), plywood KTG drums (Europe), Bayka12 of 14112 kg
1,000 mKTG 8 (800 mm flange), wood KTG drums (Europe), Bayka, KTG15 of 17241–245 kg

Barrel at least 20 × OD = 182 mm for a cable of this kind (Low voltage, single core): KTG table, the cable's datasheet wins. A load rating is the drum maker's own. A steel drum whose maker prints none is checked against the DIN 46391-4 guide load instead: 28 kN per m³ of gross winding volume.

Other lengths, drums and weights: the cable drum calculator

Load it on a truck: 1000 m on its drum in the loading planner

Laying, sizes and datasheet: NXH

Current rating and voltage drop: One circuit, C: cable on a wall, 30 °C air: about 96 A. At that current over 100 m, three-phase 400 V, cos φ 0.9: a voltage drop of about 5.6 %. Sources: IEC 60364-5-52:2009, Table B.52.5, p. 44; IEC 60228:2023 Table 4, p. 13; IEC 60228:2023 Annex B, p. 18; IEC 60364-5-52:2009 (ed. 3.0) Annex G (informative), pp. 74 to 75 (read in the standard text) Cable size calculator: smallest section for a load, every factor shown · Voltage drop calculator: IEC 60364-5-52 method and limits

NXH belongs to the family LV XLPE power cables: the lowest laying temperature, bending radius, pulling, depth, drum handling and the test after laying, every rule with its sources. Laying and handling guide: LV XLPE power cables

Its sizes are in AWG and kcmil, which are not the same as the nearest mm²: compare them by area and by resistance. AWG to mm²

Selling this cable? Open it in the designer and get a datasheet with your logo (Pro). Open the cable designer · See Pro

Work with NXH

Who makes or stocks this cable?

Makers and stockists of this cable family appear here as sponsors for your region, each marked "Sponsored"; a listing never changes what this page says about the cable.

Related cables

More DIN VDE 0250 cords, control and special cables (Germany) designations

NXH