NXH
NXH is a DIN VDE 0250 cords, control and special cables (Germany) cable designation: N = VDE Standard; X = Cross Linked Thermoplastics; H = Halogen-Free Compound (Insulation Or Sheath).
6 coding systems recognise this code
Standard, worked reading and related types
Standards behind these values: IEC 60502-1:2004 (edition 2.0): Power cables with extruded insulation and their accessories for rated voltages from 1 kV (Um = 1,2 kV) up to 30 kV (Um = 36 kV) - Part 1: Cables for rated voltages of 1 kV (Um = 1,2 kV) and 3 kV (Um = 3,6 kV); IEC 60228:2023 (edition 4.0): Conductors of insulated cables. How the values are sourced
Worked reading of NXH 1x16 0.6/1 kV:
NXH: N = VDE Standard; X = Cross Linked Thermoplastics; H = Halogen-Free Compound (Insulation Or Sheath)1x16 0.6/1 kV: one core, copper 16 mm²; rated voltage 0.6/1 kV
DIN VDE 0250 cords, control and special cables (Germany)
| Symbol | Meaning |
|---|---|
N | VDE Standard |
X | Cross Linked Thermoplastics |
H | Halogen-Free Compound (Insulation Or Sheath) |
How to read a DIN VDE 0250 cords, control and special cables (Germany) cable code
China (GB / JB/T / MT cable model codes)
| Symbol | Meaning |
|---|---|
N | Nylon Jacket |
X | Natural Or Styrene-Butadiene Rubber |
H | Rubber Sheath; Chlorosulphonated Polyethylene (CSM) Sheath In Marine Cables |
How to read a China (GB / JB/T / MT cable model codes) cable code
NEC Article 310 (US building wire, NFPA 70)
| Symbol | Meaning |
|---|---|
N | Nylon Jacket |
X | Cross-Linked Polymer Insulation |
H | 75°C Insulation |
How to read a NEC Article 310 (US building wire, NFPA 70) cable code
NEC Article 402 (US fixture wires, NFPA 70)
| Symbol | Meaning |
|---|---|
N | Nylon Jacket |
X | Cross-Linked Polyolefin Insulation |
H | 75°C Heat-Resistant Insulation (After R Or FF); ECTFE Insulation (First Letter, HF / HFF) |
How to read a NEC Article 402 (US fixture wires, NFPA 70) cable code
ZN-TF-500 (Poland, MV cables)
| Symbol | Meaning |
|---|---|
N | Low Smoke Zero Halogen Compound |
X | Polyethylene (PE) Sheath |
H | Cable With Radial Field (Screened Cores, Medium Voltage) |
Swiss cable codes (ASE/SEV wire codes and power cable codes)
| Symbol | Meaning |
|---|---|
N | Halogen-Free Thermoplastic Sheath (PE Only) |
X | Cross-Linked Polyethylene (XLPE) |
H | Cable With Radial Electric Field (Höchstädter Type) |
How to read a Swiss cable codes (ASE/SEV wire codes and power cable codes) cable code
How to read a DIN VDE 0250 cords, control and special cables (Germany) cable code
A DIN VDE 0250 cords, control and special cables (Germany) designation (Germany) is a row of letter groups, and each group stands for one part of the cable: conductor, insulation, screen, armour, sheath, or the standard it follows. The decoder knows 92 symbols for this system.
What does N mean in a DIN VDE 0250 cords, control and special cables (Germany) cable code? N means VDE Standard.
What does X mean in a DIN VDE 0250 cords, control and special cables (Germany) cable code? X means Similar To VDE Standard; or Cross Linked Thermoplastics.
What does H mean in a DIN VDE 0250 cords, control and special cables (Germany) cable code? H means Halogen-Free Compound (Insulation Or Sheath).
Fire behaviour (EU CPR)
Halogen-free compound (H). Under the CPR this shows in the additional classes: acidity a1 to a3 (EN 60754-2) and smoke s1 to s3 (EN 50399; s1a and s1b add the 3 m cube test EN 61034-2). The main class, Aca to Fca, depends on the whole construction.
Typically targeted, as declared by makers for this kind of construction in the examples this site checked (not the class of this cable):
B2ca-s1a,d0,a11-CXKH-R-J, Kablo VrchlabíCca-s1b,d1,a1FG16(O)M16, Nexans (La Triveneta Cavi)B2ca-s1a,d1,a1FG18(O)M16, Nexans (La Triveneta Cavi)DcaFXQJ, Nexans NorwayCca-s1b,d1,a1H07Z1-K, Nexans SpainB2ca-s1,d2,a1AXQJ-RMF, Prysmian Sweden (12/20 kV)B2ca-s1a,d1,a1RZ1-K (AS), Top CableCca-s1b,d1,a1RZ1FZ1-K (AS), Top Cable
Listed as sources, alphabetically by maker. No maker pays to appear here.
A CPR class is declared by the maker in its Declaration of Performance and printed on the sheath (EN 50575 cl 7). This decoder does not assign one. What the CPR classes mean →
Sources: EN 13501-6 draft and FprEN 50575:2014 final draft (drafts, not the published texts); IEC 60332-3-24:2000+A1:2008; EN 13501-3 draft A2.
NXH as the cable designer builds it, 1x16 0.6/1 kV
Overall diameter 9.1 mm, about 210 kg/km. Nominal values from the standard's tables for this size, computed, not a maker's data.
| Layer | Material | Thickness, mm | Over the layer, mm |
|---|---|---|---|
| Insulation | XLPE | 0.70 | 6.3 |
| Sheath | Halogen-free (LSZH) | 1.4 | 9.1 |
NXH on a drum
The smallest drum that passes every check, for 9.1 mm and about 210 kg/km as the cable designer builds it. Drums as their makers print them; lengths are estimates: whole layers wound nested (each turn in the groove of the layer below), wound diameter 1.05 × OD, 50 mm freeboard under the flange rim. Cable makers' own tables print less, as they count aligned layers.
| Length | Drum size (its makers) | Layers | Gross weight |
|---|---|---|---|
| 500 m | KTG 6 (600 mm flange), plywood KTG drums (Europe), Bayka | 12 of 14 | 112 kg |
| 1,000 m | KTG 8 (800 mm flange), wood KTG drums (Europe), Bayka, KTG | 15 of 17 | 241–245 kg |
Barrel at least 20 × OD = 182 mm for a cable of this kind (Low voltage, single core): KTG table, the cable's datasheet wins. A load rating is the drum maker's own. A steel drum whose maker prints none is checked against the DIN 46391-4 guide load instead: 28 kN per m³ of gross winding volume.
Other lengths, drums and weights: the cable drum calculator
Load it on a truck: 1000 m on its drum in the loading planner
Laying, sizes and datasheet: NXH
NXH belongs to the family LV XLPE power cables: the lowest laying temperature, bending radius, pulling, depth, drum handling and the test after laying, every rule with its sources. Laying and handling guide: LV XLPE power cables
Its sizes are in AWG and kcmil, which are not the same as the nearest mm²: compare them by area and by resistance. AWG to mm²
Selling this cable? Open it in the designer and get a datasheet with your logo (Pro). Open the cable designer · See Pro
Work with NXH
Who makes or stocks this cable?
Makers and stockists of this cable family appear here as sponsors for your region, each marked "Sponsored"; a listing never changes what this page says about the cable.
Related cables
More DIN VDE 0250 cords, control and special cables (Germany) designations