NHXH PH
NHXH PH is a DIN VDE 0250 cords, control and special cables (Germany) cable designation: N = VDE Standard; HX = Cross-Linked Halogen-Free Polymer Compound; H = Halogen-Free Compound (Insulation Or Sheath); P = Polyurethane (PUR) Sheath; H = Halogen-Free Compound (Insulation Or Sheath).
4 coding systems recognise this code
Standard, worked reading and related types
Worked reading of NHXH PH:
NHXH PH: N = VDE Standard; HX = Cross-Linked Halogen-Free Polymer Compound; H = Halogen-Free Compound (Insulation Or Sheath); P = Polyurethane (PUR) Sheath; H = Halogen-Free Compound (Insulation Or Sheath)
Related cable types: NHXMH · N2XHBH · NHXH · NHXHM-J · N2XHRH · N2XHCH
DIN VDE 0250 cords, control and special cables (Germany)
| Symbol | Meaning |
|---|---|
N | VDE Standard |
HX | Cross-Linked Halogen-Free Polymer Compound |
H | Halogen-Free Compound (Insulation Or Sheath) |
P | Polyurethane (PUR) Sheath |
H | Halogen-Free Compound (Insulation Or Sheath) |
How to read a DIN VDE 0250 cords, control and special cables (Germany) cable code
China (GB / JB/T / MT cable model codes)
| Symbol | Meaning |
|---|---|
NH | Fire Resistant |
X | Natural Or Styrene-Butadiene Rubber |
H | Rubber Sheath; Chlorosulphonated Polyethylene (CSM) Sheath In Marine Cables |
P | Copper Screen As Braid |
H | Rubber Sheath; Chlorosulphonated Polyethylene (CSM) Sheath In Marine Cables |
How to read a China (GB / JB/T / MT cable model codes) cable code
NEC Article 402 (US fixture wires, NFPA 70)
| Symbol | Meaning |
|---|---|
N | Nylon Jacket |
H | 75°C Heat-Resistant Insulation (After R Or FF); ECTFE Insulation (First Letter, HF / HFF) |
X | Cross-Linked Polyolefin Insulation |
H | 75°C Heat-Resistant Insulation (After R Or FF); ECTFE Insulation (First Letter, HF / HFF) |
P | Perfluor (Ethylene Propylene - FEP - Teflon) |
H | 75°C Heat-Resistant Insulation (After R Or FF); ECTFE Insulation (First Letter, HF / HFF) |
How to read a NEC Article 402 (US fixture wires, NFPA 70) cable code
Swiss cable codes (ASE/SEV wire codes and power cable codes)
| Symbol | Meaning |
|---|---|
N | Halogen-Free Thermoplastic Sheath (PE Only) |
H | Cable With Radial Electric Field (Höchstädter Type) |
X | Cross-Linked Polyethylene (XLPE) |
H | Cable With Radial Electric Field (Höchstädter Type) |
P | Paper Insulation |
H | Cable With Radial Electric Field (Höchstädter Type) |
How to read a Swiss cable codes (ASE/SEV wire codes and power cable codes) cable code
How to read a DIN VDE 0250 cords, control and special cables (Germany) cable code
A DIN VDE 0250 cords, control and special cables (Germany) designation (Germany) is a row of letter groups, and each group stands for one part of the cable: conductor, insulation, screen, armour, sheath, or the standard it follows. The decoder knows 92 symbols for this system.
What does N mean in a DIN VDE 0250 cords, control and special cables (Germany) cable code? N means VDE Standard.
What does HX mean in a DIN VDE 0250 cords, control and special cables (Germany) cable code? HX means Cross-Linked Halogen-Free Polymer Compound.
What does H mean in a DIN VDE 0250 cords, control and special cables (Germany) cable code? H means Halogen-Free Compound (Insulation Or Sheath).
What does P mean in a DIN VDE 0250 cords, control and special cables (Germany) cable code? P means Polyurethane (PUR) Sheath.
Fire behaviour (EU CPR)
Halogen-free compound (HX, H). Under the CPR this shows in the additional classes: acidity a1 to a3 (EN 60754-2) and smoke s1 to s3 (EN 50399; s1a and s1b add the 3 m cube test EN 61034-2). The main class, Aca to Fca, depends on the whole construction.
Typically targeted, as declared by makers for this kind of construction in the examples this site checked (not the class of this cable):
B2ca-s1a,d0,a11-CXKH-R-J, Kablo VrchlabíCca-s1b,d1,a1FG16(O)M16, Nexans (La Triveneta Cavi)B2ca-s1a,d1,a1FG18(O)M16, Nexans (La Triveneta Cavi)DcaFXQJ, Nexans NorwayCca-s1b,d1,a1H07Z1-K, Nexans SpainB2ca-s1,d2,a1AXQJ-RMF, Prysmian Sweden (12/20 kV)B2ca-s1a,d1,a1RZ1-K (AS), Top CableCca-s1b,d1,a1RZ1FZ1-K (AS), Top Cable
Listed as sources, alphabetically by maker. No maker pays to appear here.
A CPR class is declared by the maker in its Declaration of Performance and printed on the sheath (EN 50575 cl 7). This decoder does not assign one. What the CPR classes mean →
Sources: EN 13501-6 draft and FprEN 50575:2014 final draft (drafts, not the published texts); IEC 60332-3-24:2000+A1:2008; EN 13501-3 draft A2.
Laying, sizes and datasheet: NHXH PH
Its sizes are in AWG and kcmil, which are not the same as the nearest mm²: compare them by area and by resistance. AWG to mm²
Work with NHXH PH
Who makes or stocks this cable?
Makers and stockists of this cable family appear here as sponsors for your region, each marked "Sponsored"; a listing never changes what this page says about the cable.
Related cables
More DIN VDE 0250 cords, control and special cables (Germany) designations