NYMHY

NYMHY is a DIN VDE 0250 cords, control and special cables (Germany) cable designation: N = VDE Standard; Y = Polyvinyl Chloride (PVC); Control-Cable Key: Thermoplastics In General; MH = Connecting Cable, Moderate Mechanical Load; Y = Polyvinyl Chloride (PVC); Control-Cable Key: Thermoplastics In General.

2 coding systems recognise this code

Standard, worked reading and related types

Worked reading of NYMHY:

  • NYMHY: N = VDE Standard; Y = Polyvinyl Chloride (PVC); Control-Cable Key: Thermoplastics In General; MH = Connecting Cable, Moderate Mechanical Load; Y = Polyvinyl Chloride (PVC); Control-Cable Key: Thermoplastics In General

Related cable types: NYYHY

DIN VDE 0250 cords, control and special cables (Germany)

SymbolMeaning
NVDE Standard
YPolyvinyl Chloride (PVC); Control-Cable Key: Thermoplastics In General
MHConnecting Cable, Moderate Mechanical Load
YPolyvinyl Chloride (PVC); Control-Cable Key: Thermoplastics In General

How to read a DIN VDE 0250 cords, control and special cables (Germany) cable code

China (GB / JB/T / MT cable model codes)

SymbolMeaning
NNylon Jacket
YPolyethylene (PE) Or Polyolefin
MWatertight
HRubber Sheath; Chlorosulphonated Polyethylene (CSM) Sheath In Marine Cables
YPolyethylene (PE) Or Polyolefin

How to read a China (GB / JB/T / MT cable model codes) cable code

How to read a DIN VDE 0250 cords, control and special cables (Germany) cable code

A DIN VDE 0250 cords, control and special cables (Germany) designation (Germany) is a row of letter groups, and each group stands for one part of the cable: conductor, insulation, screen, armour, sheath, or the standard it follows. The decoder knows 92 symbols for this system.

What does N mean in a DIN VDE 0250 cords, control and special cables (Germany) cable code? N means VDE Standard.

What does Y mean in a DIN VDE 0250 cords, control and special cables (Germany) cable code? Y means Polyvinyl Chloride (PVC); Control-Cable Key: Thermoplastics In General.

What does MH mean in a DIN VDE 0250 cords, control and special cables (Germany) cable code? MH means Connecting Cable, Moderate Mechanical Load.

Fire behaviour (EU CPR)

A CPR class is declared by the maker in its Declaration of Performance and printed on the sheath (EN 50575 cl 7). This decoder does not assign one. What the CPR classes mean →

Sources: EN 13501-6 draft and FprEN 50575:2014 final draft (drafts, not the published texts); IEC 60332-3-24:2000+A1:2008; EN 13501-3 draft A2.

Work with NYMHY

Who makes or stocks this cable?

Makers and stockists of this cable family appear here as sponsors for your region, each marked "Sponsored"; a listing never changes what this page says about the cable.

Related cables

More DIN VDE 0250 cords, control and special cables (Germany) designations

NYMHY