YSLCY-OZ

YSLCY-OZ is a DIN VDE 0250 cords, control and special cables (Germany) cable designation: Y = Polyvinyl Chloride (PVC); Control-Cable Key: Thermoplastics In General; SL = Control Cable/Welding Cable; C = Shielded; Y = Polyvinyl Chloride (PVC); Control-Cable Key: Thermoplastics In General; -OZ = Without Green/Yellow Earth Core, All Cores Numbered (White Numbers On Black).

1 coding system recognises this code

Standard, worked reading and related types

Worked reading of YSLCY-OZ:

  • YSLCY-OZ: Y = Polyvinyl Chloride (PVC); Control-Cable Key: Thermoplastics In General; SL = Control Cable/Welding Cable; C = Shielded; Y = Polyvinyl Chloride (PVC); Control-Cable Key: Thermoplastics In General; -OZ = Without Green/Yellow Earth Core, All Cores Numbered (White Numbers On Black)

Related cable types: YSLY-OZ · YSLYCY-OZ · YSLCY-O · yslcy-jz · yslcy-ob

DIN VDE 0250 cords, control and special cables (Germany)

SymbolMeaning
YPolyvinyl Chloride (PVC); Control-Cable Key: Thermoplastics In General
SLControl Cable/Welding Cable
CShielded
YPolyvinyl Chloride (PVC); Control-Cable Key: Thermoplastics In General
-OZWithout Green/Yellow Earth Core, All Cores Numbered (White Numbers On Black)

How to read a DIN VDE 0250 cords, control and special cables (Germany) cable code

How to read a DIN VDE 0250 cords, control and special cables (Germany) cable code

A DIN VDE 0250 cords, control and special cables (Germany) designation (Germany) is a row of letter groups, and each group stands for one part of the cable: conductor, insulation, screen, armour, sheath, or the standard it follows. The decoder knows 92 symbols for this system.

What does Y mean in a DIN VDE 0250 cords, control and special cables (Germany) cable code? Y means Polyvinyl Chloride (PVC); Control-Cable Key: Thermoplastics In General.

What does SL mean in a DIN VDE 0250 cords, control and special cables (Germany) cable code? SL means Control Cable/Welding Cable.

What does C mean in a DIN VDE 0250 cords, control and special cables (Germany) cable code? C means Shielded.

What does -OZ mean in a DIN VDE 0250 cords, control and special cables (Germany) cable code? -OZ means Without Green/Yellow Earth Core, All Cores Numbered (White Numbers On Black).

Fire behaviour (EU CPR)

A CPR class is declared by the maker in its Declaration of Performance and printed on the sheath (EN 50575 cl 7). This decoder does not assign one. What the CPR classes mean →

Sources: EN 13501-6 draft and FprEN 50575:2014 final draft (drafts, not the published texts); IEC 60332-3-24:2000+A1:2008; EN 13501-3 draft A2.

Work with YSLCY-OZ

Who makes or stocks this cable?

Makers and stockists of this cable family appear here as sponsors for your region, each marked "Sponsored"; a listing never changes what this page says about the cable.

Related cables

More DIN VDE 0250 cords, control and special cables (Germany) designations

YSLCY-OZ