HMH- C

HMH- C is a DIN VDE 0250 cords, control and special cables (Germany) cable designation: H = Halogen-Free Compound (Insulation Or Sheath); MH = Connecting Cable, Moderate Mechanical Load; C = Shielded.

4 coding systems recognise this code

Standard, worked reading and related types

Worked reading of HMH- C:

  • HMH- C: H = Halogen-Free Compound (Insulation Or Sheath); MH = Connecting Cable, Moderate Mechanical Load; C = Shielded

Related cable types: hmh- c oz

DIN VDE 0250 cords, control and special cables (Germany)

SymbolMeaning
HHalogen-Free Compound (Insulation Or Sheath)
MHConnecting Cable, Moderate Mechanical Load
CShielded

How to read a DIN VDE 0250 cords, control and special cables (Germany) cable code

China (GB / JB/T / MT cable model codes)

SymbolMeaning
HCommunication Cable
MWatertight
HRubber Sheath; Chlorosulphonated Polyethylene (CSM) Sheath In Marine Cables
CHeavy Duty (Characteristic Letter, As In YC)

How to read a China (GB / JB/T / MT cable model codes) cable code

Norwegian type designation (NEK 606 offshore and Norwegian land cables)

SymbolMeaning
HChlorosulphonated Polyethylene (CSP)
MPolyester (Nexans Norway key: aluminium + plastic + steel tape, when the 3rd letter is taken)
HSteel Tape + Steel Wires
CPolychloroprene (Neoprene, PCP) or Chlorinated Polyethylene (CPE) (Nexans Norway key: improved hydrocarbon resistance)

How to read a Norwegian type designation (NEK 606 offshore and Norwegian land cables) cable code

NEN 3207 / KEMA (Netherlands)

SymbolMeaning
HWith Auxiliary Conductor(s)
MSolid Conductor (Massief, Class 1)
HWith Auxiliary Conductor(s)
CChloroprene Rubber

How to read a NEN 3207 / KEMA (Netherlands) cable code

How to read a DIN VDE 0250 cords, control and special cables (Germany) cable code

A DIN VDE 0250 cords, control and special cables (Germany) designation (Germany) is a row of letter groups, and each group stands for one part of the cable: conductor, insulation, screen, armour, sheath, or the standard it follows. The decoder knows 92 symbols for this system.

What does H mean in a DIN VDE 0250 cords, control and special cables (Germany) cable code? H means Halogen-Free Compound (Insulation Or Sheath).

What does MH mean in a DIN VDE 0250 cords, control and special cables (Germany) cable code? MH means Connecting Cable, Moderate Mechanical Load.

What does C mean in a DIN VDE 0250 cords, control and special cables (Germany) cable code? C means Shielded.

Fire behaviour (EU CPR)

  • Halogen-free compound (H). Under the CPR this shows in the additional classes: acidity a1 to a3 (EN 60754-2) and smoke s1 to s3 (EN 50399; s1a and s1b add the 3 m cube test EN 61034-2). The main class, Aca to Fca, depends on the whole construction.

    Typically targeted, as declared by makers for this kind of construction in the examples this site checked (not the class of this cable):

    Listed as sources, alphabetically by maker. No maker pays to appear here.

A CPR class is declared by the maker in its Declaration of Performance and printed on the sheath (EN 50575 cl 7). This decoder does not assign one. What the CPR classes mean →

Sources: EN 13501-6 draft and FprEN 50575:2014 final draft (drafts, not the published texts); IEC 60332-3-24:2000+A1:2008; EN 13501-3 draft A2.

Work with HMH- C

Who makes or stocks this cable?

Makers and stockists of this cable family appear here as sponsors for your region, each marked "Sponsored"; a listing never changes what this page says about the cable.

Related cables

More DIN VDE 0250 cords, control and special cables (Germany) designations