Laying and handling guide

Aerial bundled cables: laying and handling

Aerial bundled and preassembled cables, with or without a messenger: HD 626, HD 620 10-I2, HD 603 7-B.

Every line names every source that states it and how it was seen; where sources disagree, each value is shown with its source. IEC, EN and HD documents and makers come first, national rules after them with their country.

Laying temperature and pre-warming

National rules

  • Italy HD 603 7-A, 7-B: At least 0 °C, while laying or handling.Sources: HD 603 7-B-19 item 5.2 (read in the standard text)
  • Italy HD 620 10-I1, 10-I2, 12-I: At least -25 °C, while laying or handling.Sources: HD 620 10-I1-15, 10-I2-17, 12-I-16 (read in the standard text)

Laying in winter? Pro checks your town and month against this limit. See Pro

Bending radius

National rules

  • Italy HD 603 7-A: 14 D while laying; 7 D for one controlled bend.Sources: HD 603 7-A-23 (read in the standard text)
  • Italy HD 603 7-B: 18 D while laying; 9 D for one controlled bend. D here is the diameter of the largest single core.Sources: HD 603 7-B-20 (read in the standard text)
  • Italy HD 620 10-I2: 21 D while laying; 10.5 D for one controlled bend. D here is the core diameter.Sources: HD 620 10-I2-17 (read in the standard text)

Pulling force and method

National rules

  • Italy HD 620 10-I2: Preassembled cable with a messenger: the stocking on the messenger carries the load, a second stocking on the bundle only holds the cores; the maximum stress is the maker's.Sources: HD 620 10-I2-17 items 5.3, 5.3.1 (read in the standard text)
  • Italy HD 603 7-A, 7-B · HD 620 10-I1, 10-I3, 12-I: On a cable grip at most 10 000 N; on aluminium conductors 30 N/mm².Sources: HD 603 7-A-23, 7-B-20; HD 620 10-I1-16, 10-I3-16, 12-I-17 (read in the standard text)

Work out the pull for your route: the verdict is free, the numbers and the PDF come with Pro. Pull calculation in the cable designer · See Pro

Depth, cover and laying

National rules

  • Italy HD 603 7-A · HD 620 10-I1, 10-I2, 12-I: Brackets every 20 D or 2 m, whichever is lower; 50 % more on vertical runs.Sources: HD 603 7-A-22 5.1.3; HD 620 10-I1-15 5.1.3 (read in the standard text)

Drum handling

  • Keep the drum upright, its axis horizontal, in storage and in transport; never lay it flat on a flange.Sources: HD 620 Part 1 A.3.2.5, A.3.3.2; IS 1255 7.7, p. 25; Prysmian 2024; Reka (read in the standard text)
  • Never drop a drum. Without lifting gear, use a ramp of about 1:4 (IS 1255: 1:3 to 1:4) with ropes or a winch and a sand bed at the foot.Sources: HD 620 Part 1 A.3.3.3; HD 603 3-I 3.3; IS 1255 7.3, p. 24; Prysmian 2024 p. 6; Reka p. 6; Nexans 2021 p. 4 (read in the standard text)
  • Roll it only short distances on firm ground, in the direction of the arrow on the flange.Sources: HD 620 Part 1 A.3.3.4; HD 603 3-I, 3-L; IS 1255 7.4, p. 24; Prysmian 2024 p. 7; Nexans 2021 p. 3 (read in the standard text)
  • Store it on level, firm, well-drained ground and turn it 90° every 3 months.Sources: IS 1255 7.5, 7.6, pp. 24 to 25; Prysmian 2024 p. 8, 9; Nexans 2021 p. 8, 9; Prysmian Türkiye 3.3 (read in the standard text)
  • Leave the battens on until the cable is about to be laid: they keep off sun and knocks.Sources: HD 620 Part 1 A.3.2.5; BS 6622 D.5.2; IS 1255 7.8, p. 25; Nexans 2021 p. 11 (read in the standard text)
  • Cable ends sealed with caps in transport, storage and laying. A cap missing for over a month, or a wet end: cut back 300 mm, check for moisture and cap again.Sources: HD 620 Part 1 A.3.2.3, A.4.7; HD 603 3-I 3.2; BS 6622 C.3; BS 5467 B.4; BS 7846 A.7.4; IS 1255 7.2, p. 24; Nexans 2021 p. 7; Draka (read in the standard text)
  • Pay out tangentially, never over the flange, with the drum on an axle and jacks and braked. Top or bottom: IS 1255 says off the top; Southwire chooses by where the cable goes (the bottom into a floor conduit, the top into a tray); Nexans Belgium says the bottom, for safety.Sources: HD 620 Part 1 A.4.5; IS 1255 8.2, 8.3, 10.2; Southwire 2005 p. 2 to 3; Nexans Belgium FAQ; Prysmian 2024 p. 10; Draka p. 5, 9 (read in the standard text)

Sheath test after laying

No sheath test after laying was found for this family.