How to read a cable code: guides per coding system · BS 6004 / BS 6500 / BS 7211 type numbers (UK) · UK
BS 6004 / BS 6500 / BS 7211 type numbers (UK): how to read the cable type names
Each name in BS 6004 / BS 6500 / BS 7211 type numbers (UK) stands for a whole cable type: 3182Y, for example, comes with its own construction, standard and rating. The decoder knows 36 types of this system. Below: how the names are built, every type with its rating, and the sources the table names.
How a name is built
The type table splits each name into parts and records what each part means. A few names taken apart:
3182Y
| 318 | Circular flexible cord for ordinary duty |
| 2 | Number of cores: 2 |
| Y | PVC insulation and PVC sheath |
3182Y: ordinary duty 2 core circular PVC flexible cord (the UK number of H05VV-F)
3183Y
| 318 | Circular flexible cord for ordinary duty |
| 3 | Number of cores: 3 |
| Y | PVC insulation and PVC sheath |
3183Y: ordinary duty 3 core circular PVC flexible cord (the UK number of H05VV-F)
6242Y
| 624 | Flat wiring cable with a bare copper circuit protective conductor (CPC) beside the cores |
| 2 | Number of cores: 2 |
| Y | PVC insulation and PVC sheath |
6242Y: flat twin and earth, PVC insulated cores and a bare copper CPC in a PVC sheath
6243B
| 624 | Flat wiring cable with a bare copper circuit protective conductor (CPC) beside the cores |
| 3 | Number of cores: 3 |
| B | Low smoke, halogen-free (LSZH / LSF) materials |
6243B: flat three core and earth, low smoke version: XLPE insulated cores and a bare CPC in an LSF sheath
Every part used in the names
| Part | Meaning | Used in |
|---|---|---|
| Y | PVC insulation and PVC sheath | 6181Y 6192Y 6193Y 6241Y 6242Y 6243Y 2182Y 2183Y 2184Y 2192Y 3182Y 3183Y 3184Y 3093Y |
| 3 | Number of cores: 3 | 6193Y 6243Y 6243B 2183Y 3183Y 3093Y 3183TQ 3183TRS 6943X 6943B |
| 2 | Number of cores: 2 | 6192Y 6242Y 6242B 2182Y 2192Y 3182Y 6942X 6942B |
| 694 | Steel wire armoured (SWA) power cable, 600/1000 V | 6942X 6943X 6944X 6945X 6942B 6943B 6944B 6945B |
| B | Low smoke, halogen-free (LSZH / LSF) materials | 6242B 6243B 6491B 6942B 6943B 6944B 6945B |
| 1 | Number of cores: 1 | 6181Y 6181XY 6241Y 6491X 6491B |
| 624 | Flat wiring cable with a bare copper circuit protective conductor (CPC) beside the cores | 6241Y 6242Y 6243Y 6242B 6243B |
| 318 | Circular flexible cord for ordinary duty | 3182Y 3183Y 3184Y 3183TQ 3183TRS |
| 4 | Number of cores: 4 | 2184Y 3184Y 6944X 6944B |
| X | XLPE insulation, PVC bedding and PVC sheath (BS 5467) | 6942X 6943X 6944X 6945X |
| 218 | Light duty circular flexible cord, PVC, 300/300 V | 2182Y 2183Y 2184Y |
| 618 | Single-core sheathed cable, one insulated core in its own sheath | 6181Y 6181XY |
| 619 | Flat cable, cores side by side, no protective conductor | 6192Y 6193Y |
| 649 | Single-core non-sheathed cable (insulation only), for conduit and trunking | 6491X 6491B |
| 5 | Number of cores: 5 | 6945X 6945B |
| XY | XLPE insulation, PVC sheath | 6181XY |
| X | PVC insulation, no sheath | 6491X |
| 219 | Light duty flat twin flexible cord, PVC, 300/300 V | 2192Y |
| 309 | Heat resisting PVC flexible cord, 90 C | 3093Y |
| TQ | EPR (cross-linked elastomer) insulation, CSP sheath; heat, oil and flame resisting, 90 C | 3183TQ |
| TRS | Tough rubber sheath: rubber insulation and rubber sheath, 60 C | 3183TRS |
| FP200 | A Prysmian brand name, not a standard; the cable is made to BS 7629-1 | FP200 Gold |
Every type in BS 6004 / BS 6500 / BS 7211 type numbers (UK)
| Type | Description | Rating |
|---|---|---|
6181Y | 6181Y: single-core PVC insulated and PVC sheathed (double insulated) wiring cable, the usual meter tails | 300/500 V, 70 C maximum conductor temperature (Anixter p. 1:4) |
6181XY | 6181XY: single-core XLPE insulated, PVC sheathed wiring cable, 600/1000 V (BS 7889) | 600/1000 V, -15 to 90 C (RR Kabel) |
6192Y | 6192Y: flat twin PVC insulated and PVC sheathed wiring cable, no protective conductor | 300/500 V, 70 C maximum conductor temperature (Anixter p. 1:6) |
6193Y | 6193Y: flat three core PVC insulated and PVC sheathed wiring cable, no protective conductor | 300/500 V, 70 C maximum conductor temperature (Anixter p. 1:6) |
6241Y | 6241Y: flat single core and earth, a PVC insulated core and a bare CPC in a PVC sheath (lighting and switching circuits) | 300/500 V, 70 C maximum conductor temperature (Prysmian) |
6242Y | 6242Y: flat twin and earth, PVC insulated cores and a bare copper CPC in a PVC sheath | 300/500 V, 70 C maximum conductor temperature (Anixter p. 1:6) |
6243Y | 6243Y: flat three core and earth, PVC insulated cores and a bare copper CPC in a PVC sheath | 300/500 V, 70 C maximum conductor temperature (Anixter p. 1:6) |
6242B | 6242B: flat twin and earth, low smoke version: XLPE insulated cores and a bare CPC in an LSF sheath | 300/500 V; Anixter p. 1:44 gives 70 C maximum conductor temperature (superlecdirect lists -25 to +90 C) |
6243B | 6243B: flat three core and earth, low smoke version: XLPE insulated cores and a bare CPC in an LSF sheath | 300/500 V; Anixter p. 1:44 gives 70 C maximum conductor temperature (superlecdirect lists -25 to +90 C) |
6491X | 6491X: single-core PVC insulated, non-sheathed conduit and trunking wire (the UK number of H07V-U / H07V-R) | 450/750 V, 70 C maximum conductor temperature (Anixter p. 1:2) |
6491B | 6491B: single-core low smoke halogen-free (LSF) insulated, non-sheathed wire (the UK number of H07Z-U / H07Z-R) | 450/750 V from 1.5 mm2 (300/500 V up to 1.0 mm2), 90 C maximum conductor temperature (Anixter p. 1:18) |
2182Y | 2182Y: light duty 2 core circular PVC flexible cord (the UK number of H03VV-F) | 300/300 V, 70 C maximum (Clynder) |
2183Y | 2183Y: light duty 3 core circular PVC flexible cord (the UK number of H03VV-F) | 300/300 V, 70 C maximum (Clynder) |
2184Y | 2184Y: light duty 4 core circular PVC flexible cord (the UK number of H03VV-F) | 300/300 V, 70 C maximum (Clynder) |
2192Y | 2192Y: light duty flat twin PVC flexible cord (the UK number of H03VVH2-F) | 300/300 V, 70 C maximum (Clynder) |
3182Y | 3182Y: ordinary duty 2 core circular PVC flexible cord (the UK number of H05VV-F) | 300/500 V, 70 C maximum (Doncaster; RS PRO) |
3183Y | 3183Y: ordinary duty 3 core circular PVC flexible cord (the UK number of H05VV-F) | 300/500 V, 70 C maximum (Doncaster; RS PRO) |
3184Y | 3184Y: ordinary duty 4 core circular PVC flexible cord (the UK number of H05VV-F) | 300/500 V, 70 C maximum (Doncaster; RS PRO) |
3093Y | 3093Y: heat resisting 3 core PVC flexible cord, 90 C (the UK number of H05V2V2-F) | 300/500 V (H05), -15 to 90 C (Doncaster) |
3183TQ | 3183TQ: heat, oil and flame resisting 3 core rubber flexible cord, EPR insulated, CSP sheathed (the UK number of H07BN4-F) | 450/750 V (H07), -20 to 90 C (Doncaster) |
3183TRS | 3183TRS: tough rubber sheathed 3 core flexible cord (the UK number of H05RR-F) | 300/500 V (H05; Lapp H05RR-F), -25 to 60 C (Doncaster) |
6942X | 6942X: 2 core XLPE insulated, PVC bedded, steel wire armoured, PVC sheathed power cable (Cu/XLPE/PVC/SWA/PVC, BS 5467) | 600/1000 V, 90 C maximum conductor temperature (BS 5467 cl. 1) |
6943X | 6943X: 3 core XLPE insulated, PVC bedded, steel wire armoured, PVC sheathed power cable (Cu/XLPE/PVC/SWA/PVC, BS 5467) | 600/1000 V, 90 C maximum conductor temperature (BS 5467 cl. 1) |
6944X | 6944X: 4 core XLPE insulated, PVC bedded, steel wire armoured, PVC sheathed power cable (Cu/XLPE/PVC/SWA/PVC, BS 5467) | 600/1000 V, 90 C maximum conductor temperature (BS 5467 cl. 1) |
6945X | 6945X: 5 core XLPE insulated, PVC bedded, steel wire armoured, PVC sheathed power cable (Cu/XLPE/PVC/SWA/PVC, BS 5467) | 600/1000 V, 90 C maximum conductor temperature (BS 5467 cl. 1) |
6942B | 6942B: 2 core XLPE insulated, LSZH bedded, steel wire armoured, LSZH sheathed power cable (Cu/XLPE/LSZH/SWA/LSZH, BS 6724) | 600/1000 V, 90 C maximum conductor temperature (BS 6724) |
6943B | 6943B: 3 core XLPE insulated, LSZH bedded, steel wire armoured, LSZH sheathed power cable (Cu/XLPE/LSZH/SWA/LSZH, BS 6724) | 600/1000 V, 90 C maximum conductor temperature (BS 6724) |
6944B | 6944B: 4 core XLPE insulated, LSZH bedded, steel wire armoured, LSZH sheathed power cable (Cu/XLPE/LSZH/SWA/LSZH, BS 6724) | 600/1000 V, 90 C maximum conductor temperature (BS 6724) |
6945B | 6945B: 5 core XLPE insulated, LSZH bedded, steel wire armoured, LSZH sheathed power cable (Cu/XLPE/LSZH/SWA/LSZH, BS 6724) | 600/1000 V, 90 C maximum conductor temperature (BS 6724) |
BS 7629-1 | BS 7629-1: fire resistant 300/500 V cable for fire alarm and emergency lighting circuits, screened, with an uninsulated CPC under the screen, LSZH sheath | 300/500 V, 70 C maximum conductor temperature (Anixter p. 1:32) |
FP200 Gold | FP200 Gold: Prysmian's brand name (not a standard) for its BS 7629-1 fire resistant cable: EI 5 insulation, aluminium screen, uninsulated tinned copper CPC, LSZH sheath | 300/500 V, 70 C maximum conductor temperature (Prysmian) |
CW1308 | CW1308: BT internal telephone cable, solid 0.5 mm copper pairs, PVC insulation and PVC (or LSZH) sheath | telephone (low-voltage signalling) |
CW1308B | CW1308B: the external version of CW1308 | telephone (low-voltage signalling) |
CW1128 | CW1128: BT external telephone cable, jelly-filled (petroleum jelly) core, polyethylene sheath, for ducts | telephone (low-voltage signalling) |
CW1198 | CW1198: BT armoured external telephone cable, CW1128 with galvanised steel wire armour, for direct burial | telephone (low-voltage signalling) |
CW1600 | CW1600: BT limited-fire-hazard internal telephone cable, 0.5 mm conductors, metallised polyester tape screen, halogen-free sheath | telephone (low-voltage signalling) |
Common questions
What is 3182Y cable?
3182Y: ordinary duty 2 core circular PVC flexible cord (the UK number of H05VV-F). Rating: 300/500 V, 70 C maximum (Doncaster; RS PRO). Standard: BS EN 50525-2-11 (formerly BS 6500); harmonised H05VV-F. The name reads: 318 (Circular flexible cord for ordinary duty) + 2 (Number of cores: 2) + Y (PVC insulation and PVC sheath).
What is 3183Y cable?
3183Y: ordinary duty 3 core circular PVC flexible cord (the UK number of H05VV-F). Rating: 300/500 V, 70 C maximum (Doncaster; RS PRO). Standard: BS EN 50525-2-11 (formerly BS 6500); harmonised H05VV-F. The name reads: 318 (Circular flexible cord for ordinary duty) + 3 (Number of cores: 3) + Y (PVC insulation and PVC sheath).
What is the difference between 3182Y and 3183Y?
3182Y: ordinary duty 2 core circular PVC flexible cord (the UK number of H05VV-F), 300/500 V, 70 C maximum (Doncaster; RS PRO). 3183Y: ordinary duty 3 core circular PVC flexible cord (the UK number of H05VV-F), 300/500 V, 70 C maximum (Doncaster; RS PRO). The names differ in: 3182Y: 2 (Number of cores: 2); 3183Y: 3 (Number of cores: 3).
BS 6004 / BS 6500 / BS 7211 type numbers (UK): what does Y mean in a cable name?
Y means: PVC insulation and PVC sheath. Used in 6181Y, 6192Y, 6193Y, 6241Y, 6242Y, 6243Y, 2182Y, 2183Y +6.
What is 6242Y cable?
6242Y: flat twin and earth, PVC insulated cores and a bare copper CPC in a PVC sheath. Rating: 300/500 V, 70 C maximum conductor temperature (Anixter p. 1:6). Standard: BS 6004 (Anixter p. 1:6; Prysmian). The name reads: 624 (Flat wiring cable with a bare copper circuit protective conductor (CPC) beside the cores) + 2 (Number of cores: 2) + Y (PVC insulation and PVC sheath).
What is 6243B cable?
6243B: flat three core and earth, low smoke version: XLPE insulated cores and a bare CPC in an LSF sheath. Rating: 300/500 V; Anixter p. 1:44 gives 70 C maximum conductor temperature (superlecdirect lists -25 to +90 C). Standard: BS 7211 (Anixter p. 1:44). The name reads: 624 (Flat wiring cable with a bare copper circuit protective conductor (CPC) beside the cores) + 3 (Number of cores: 3) + B (Low smoke, halogen-free (LSZH / LSF) materials).
Sources the type table names
Standards named in the table
- BS 6004 (Anixter p. 1:4
- Doncaster: BS 6004:2012)
- BS 7889 (RR Kabel 6181XY
- Prysmian BS 7889 listings)
- BS 6004 (Anixter p. 1:6)
- BS 6004 (Prysmian 6241Y datasheet)
- BS 6004 (Anixter p. 1:6
- Prysmian)
- BS 7211 (Anixter p. 1:44)
- BS 6004 and harmonised H07V-U / H07V-R (Anixter p. 1:2)
- now BS EN 50525-2-31
- BS 7211 and harmonised H07Z-U / H07Z-R (Anixter p. 1:18)
- now BS EN 50525-3-41
- BS EN 50525-2-11 (formerly BS 6500)
- harmonised H03VV-F (Clynder 218-Y)
- BS EN 50525-2-11
- harmonised H03VVH2-F (Clynder)
- harmonised H05VV-F
- Harmonised H05V2V2-F, cable type 309-Y (Doncaster)
- Harmonised H07BN4-F, cable type 318-TQ (Doncaster)
- BS EN 50525-2-21
- Harmonised H05RR-F, cable type 318-TRS (Doncaster)
- BS 5467 Table 6 (2 core, stranded copper)
- BS 5467 Table 8 (3 core, stranded copper)
- BS 5467 Table 10 (4 core, stranded copper)
- BS 5467 Table 13 (5 core, stranded copper)
- BS 6724 Table 6 (2 core, stranded copper)
- BS 6724 Table 8 (3 core, stranded copper)
- BS 6724 Table 10 (4 core, stranded copper)
- BS 6724 Table 13 (5 core, stranded copper)
- BS 7629-1 (Anixter p. 1:32
- Prysmian FP200 Gold)
- BS 7629-1 (Prysmian FP200 Gold
- FP200 is a brand, the standard is BS 7629-1)
- BT CW 1308 (British Telecom specification)
- BT CW 1308B (British Telecom specification)
- BT CW 1128 (British Telecom specification)
- BT CW 1198 (British Telecom specification)
- BT CW 1600 (British Telecom specification)
Documents and pages the readings were taken from
- Anixter EMEA Wire & Cable catalogue, Section 1 Power and Wiring Cables, p. 1:4 to 1:5 (BS6004, PVC TI 1 insulation, PVC Type 6 sheath to BS 7655, 1.0 to 35 mm2) (owner's copy, EMEA-WC-Sec-1.pdf, research/standards-local/b-british/INVENTORY.md) [seen: secondary, distributor catalogue]
- yesss.co.uk/6181y-16-0-blue-blue-100-mtr-rls : Doncaster Cables 6181Y, …
- screwfix.com/p/prysmian-6181y-grey-1-core-16mm-meter-tails-cable-5m-coi…
- rrkabel.com/products/6181xy-bs-7889/ : RR Kabel 6181XY, BS 7889, 600/10…
- voltimum.co.uk/product-details/6jBEbJ9q/prysmian/bs7889-1x16-cut-black-…
- Anixter EMEA Wire & Cable catalogue, Section 1 Power and Wiring Cables, p. 1:6 to 1:7 (core colours: 2 core brown, blue; 3 core brown, black, grey; 1.0 to 16 mm2) (owner's copy, EMEA-WC-Sec-1.pdf, research/standards-local/b-british/INVENTORY.md) [seen: secondary, distributor catalogue]
- datasheet.prysmian.com/pdf/datasheet/en-GB/312413 : Prysmian 6241Y 'PVC…
- cef.co.uk/catalogue/products/2403833-h6241y-1-0mm-single-core-cable-bro…
- Anixter EMEA Wire & Cable catalogue, Section 1 Power and Wiring Cables, p. 1:6 to 1:7 (BS6004; PVC TI 1, PVC Type 6 sheath; core colours brown, blue; CPC between brown and blue) (owner's copy, EMEA-WC-Sec-1.pdf, research/standards-local/b-british/INVENTORY.md) [seen: secondary, distributor catalogue]
- research/new-standards/bs-uk.md row 6: voltimum.co.uk Prysmian 6242Y listing, BS 6004, 300/500 V, 1.0 to 10 mm2 [seen: secondary]
- Anixter EMEA Wire & Cable catalogue, Section 1 Power and Wiring Cables, p. 1:6 to 1:7 (BS6004; PVC TI 1, PVC Type 6 sheath; core colours brown, black, grey; CPC between black and grey) (owner's copy, EMEA-WC-Sec-1.pdf, research/standards-local/b-british/INVENTORY.md) [seen: secondary, distributor catalogue]
- Anixter EMEA Wire & Cable catalogue, Section 1 Power and Wiring Cables, p. 1:44 to 1:45 (BS7211; XLPE GP 8 to BS 7655; LSF sheath LTS 2 to BS 7655; 1.0 to 16 mm2; same CPC sizes as 6242Y / 6243Y) (owner's copy, EMEA-WC-Sec-1.pdf, research/standards-local/b-british/INVENTORY.md) [seen: secondary, distributor catalogue]
- superlecdirect.com/6242b-10mm-twin-and-earth-wiring-cable-lszh-50m-reel…
- Anixter EMEA Wire & Cable catalogue, Section 1 Power and Wiring Cables, p. 1:2 to 1:3 (BS6004 and Cenelec H07V-U solid / H07V-R stranded; PVC TI 1 to BS EN 50363-3; 1.5 to 630 mm2) (owner's copy, EMEA-WC-Sec-1.pdf, research/standards-local/b-british/INVENTORY.md) [seen: secondary, distributor catalogue]
- research/new-standards/bs-uk.md rows 8 and 9: voltimum Prysmian 6491X and superlecdirect, BS EN 50525-2-31 [seen: secondary]
- Anixter EMEA Wire & Cable catalogue, Section 1 Power and Wiring Cables, p. 1:18 to 1:19 (BS7211; low smoke zero halogen thermosetting insulation EI 5 to BS EN 50363-5; 1.5 to 630 mm2) (owner's copy, EMEA-WC-Sec-1.pdf, research/standards-local/b-british/INVENTORY.md) [seen: secondary, distributor catalogue]
- research/new-standards/bs-uk.md row 10: superlecdirect 6491B, H07Z-R, BS EN 50525-3-41 [seen: secondary]
- clyndercables.co.uk/products/218-y-cable/ : Clynder 218-Y (H03VV-F), 21…
- farnell.com/datasheets/3049375.pdf : Multicomp Pro 218-Y / H03VV-F, BS …
- clyndercables.co.uk/products/2192y-cable/ : Clynder 2192Y H03VVH2-F, BS…
- yesss.co.uk/3183y-15-white-50-mtr-rls : Doncaster Cables 3183Y, cable t…
- befr.rs-online.com/web/p/power-cable/8114387 : RS PRO 3183Y, H05VV-F, B…
- cdn.yesss.co.uk/documents/58404.pdf : 318-Y H05VV-F datasheet, 3182Y / …
- yesss.co.uk/3093y-15-white-10m-coil : Doncaster Cables 3093Y, cable typ…
- edwardes.co.uk/products/cut-to-required-metre-of-1-0mm-3093y-3-core-hea…
- yesss.co.uk/3183tq-15mm-rubber-sheathed-flexible-cable-white-50m-drum :…
- cdn.yesss.co.uk/documents/58404.pdf : 318-TQ EPR insulated and CSP shea…
- yesss.co.uk/3183-15-trs-100-mtr-rls-2 : Doncaster Cables 31831.5100, ca…
- dam-media.lapp.com/8/892/89263/e8dd47838b6b4e18964fb716c1cf1357.pdf : L…
- BS 5467:1997+A3:2008 (owner's copy): cl. 1 scope 600/1000 V, 90 C; cl. 6 XLPE GP 8; cl. 7.1 core colours; cl. 9 extruded bedding; cl. 10 and Table 1 galvanised steel wire armour; cl. 11 PVC Type 9 oversheath; Tables 6 (2 core), 8 (3 core), 10 (4 core), 13 (5 core) (research/standards-local/b-british/INVENTORY.md) [seen: standard]
- electrical4less.co.uk/wp-content/uploads/2025/08/SWA-H694-XL-BS5467-Dat…
- kr.element14.com/multicomp-pro/pp-6942x1-5mm-xlpe-swa-pvc/shld-flex-cab…
- es.farnell.com/en-ES/multicomp-pro/pp-6943x2-5mm-xlpe-swa-pvc/shld-flex…
- buymaterials.com/product/751877 : 6943X BS5467 SWA PVC XLPE armoured ca…
- yesss.co.uk/h-6944x-60-xlpeswapvc : Doncaster Cables H6944XL6.0, XLPE i…
- electrical4less.co.uk/product/5-core-1-5mm²-h6945xl1-5-xlpe-swa-pvc-ste…
- BS 6724:1997+A3:2008 (owner's copy): 600/1000 V, 90 C; XLPE GP 8 insulation; LSZH bedding; galvanised steel wire armour; LTS 1 oversheath (BS 7655-6.1); Tables 6, 8, 10, 13 as BS 5467; core colours as BS 5467 (research/standards-local/b-british/INVENTORY.md) [seen: standard]
- electrical4less.co.uk/product/4-core-1-5mm²-6944b-xlpe-lszh-swa-cable-1…
- Anixter EMEA Wire & Cable catalogue, Section 1 Power and Wiring Cables, p. 1:32 to 1:33 (BS7629 Part 1; based on Draka Firetuf: silicone rubber EI 2 insulation, woven glass tape, tinned copper CPC under and in contact with an aluminium/mylar tape, LSZH sheath LTS 3; 2, 3, 4 core brown, blue / brown, black, grey / brown, black, grey, blue; 7, 12, 19 core; 1.0 to 4.0 mm2) (owner's copy, EMEA-WC-Sec-1.pdf, research/standards-local/b-british/INVENTORY.md) [seen: secondary, distributor catalogue]
- uk.prysmian.com/sites/uk.prysmian.com/files/media/documents/FP200 Gold …
- datasheet.prysmian.com/pdf/datasheet/en-GB/312420 : Prysmian FP200 Gold…
- elandcables.com/cables/cw1128-external-telephone-cable
- fscables.com/categories.html
- Tele-Fonika Kable export catalogue 2008 (owner's library: docs/Kablo Kodları/Polonya mı çek mi tfk_export_2008.pdf), telephone cables 'CW 1128 ... 2-100x2, 0,4 to 0,9 mm'
- uk-store.netceed.com/bcc-voice-cable-cw1600-50-pair-screened-lszh-inter…
- uk.rs-online.com/web/p/telephone-cable/5202863
Taken from the type table of this site, with the sources named above. Check the manufacturer's datasheet before you specify a cable.
Every type in BS 6004 / BS 6500 / BS 7211 type numbers (UK) · Decode your own designation