2192Y
2192Y is a BS 6004 / BS 6500 / BS 7211 type numbers (UK) cable designation: 219 = Light duty flat twin flexible cord, PVC, 300/300 V; 2 = Number of cores: 2; Y = PVC insulation and PVC sheath; 2192Y = 2192Y: light duty flat twin PVC flexible cord (the UK number of H03VVH2-F). 300/300 V, 70 C maximum (Clynder). BS EN 50525-2-11; harmonised H03VVH2-F (Clynder).
1 coding system recognises this code
BS 6004 / BS 6500 / BS 7211 type numbers (UK)
| Symbol | Meaning |
|---|---|
219 | Light duty flat twin flexible cord, PVC, 300/300 V |
2 | Number of cores: 2 |
Y | PVC insulation and PVC sheath |
2192Y | 2192Y: light duty flat twin PVC flexible cord (the UK number of H03VVH2-F). 300/300 V, 70 C maximum (Clynder). BS EN 50525-2-11; harmonised H03VVH2-F (Clynder) |
Fire behaviour (EU CPR)
PVC sheath (Y).
Typically targeted, as declared by makers for this kind of construction in the examples this site checked (not the class of this cable):
EcaN1XV-R, Ahlsell (seller)Cca-s3,d1,a3FG16OR16, Nexans (La Triveneta Cavi)EcaU1000 R2V, Nexans (La Triveneta Cavi)EcaN2XSY, Waskönig+Walter (10 kV datasheet)
Listed as sources, alphabetically by maker. No maker pays to appear here.
A CPR class is declared by the maker in its Declaration of Performance and printed on the sheath (EN 50575 cl 7). This decoder does not assign one. What the CPR classes mean →
Sources: EN 13501-6 draft and FprEN 50575:2014 final draft (drafts, not the published texts); IEC 60332-3-24:2000+A1:2008; EN 13501-3 draft A2.
2192Y as the cable designer builds it, 2x0.75 300/300 V
Flat, 5.4 × 3.3 mm (width × thickness), about 30 kg/km. Nominal values from the standard's tables for this size, computed, not a maker's data.
| Layer | Material | Thickness, mm | Over the layer, mm |
|---|---|---|---|
| Insulation | PVC | 0.50 | 2.1 |
| Filler | PVC | 2.1 | |
| Sheath | PVC | 0.60 | 3.3 |
2192Y on a drum
The smallest drum that passes every check, for 5.4 mm and about 30 kg/km as the cable designer builds it. Drums as their makers print them; lengths are estimates within a few per cent of the cable makers' own tables: whole layers, wound diameter 1.05 × OD, 50 mm freeboard under the flange rim.
| Length | Drum size (its makers) | Layers | Gross weight |
|---|---|---|---|
| 500 m | KTG 3 (390 mm flange), plastic KTG drums (Europe), KTG | 12 of 14 | 17 kg |
| 1,000 m | KTG 5 (500 mm flange), plastic KTG drums (Europe), Bayka, KTG | 18 of 22 | 33–34 kg |
Barrel at least 12 × OD = 65 mm for a cable of this kind (Flexible cable (class 5 or 6 conductor)): KTG table, the cable's datasheet wins. A load rating is the drum maker's own.
Other lengths, drums and weights: the cable drum calculator
Load it on a truck: 1000 m on its drum in the loading planner
Laying, sizes and datasheet: 2192Y