NYIF

NYIF es una designación de cable según Designaciones de tipo DIN VDE (Alemania): N = Tipo nacional alemán (VDE); Y = Aislamiento de conductores de PVC (YI 1); IF = Stegleitung: conductor plano con alma, los conductores uno al lado de otro en una envoltura exterior común unida por un alma; sin otra letra la envoltura es de goma (NYIF); Y = Envoltura exterior de PVC (YM 1), NYIFY; NYIF = NYIF / NYIFY: flat webbed installation wire (Stegleitung), PVC insulated solid copper cores side by side in an outer covering of rubber (NYIF) or PVC (NYIFY). U0/U 230/400 V (clause 3); for laying in and under plaster, DIN VDE 0298-3 (clause 6). DIN VDE 0250-201:1992-09 (2 and 3 cores 1,5 to 4 mm², 4 and 5 cores 1,5 and 2,5 mm², 4.1; bare solid copper class 1, 4.2; PVC insulation YI 1, 0,4 / 0,5 / 0,6 mm at 1,5 / 2,5 / 4 mm², 4.3 and Table 1 column 6; cores side by side, 4.5; outer covering vulcanised rubber (NYIF) or PVC YM 1 (NYIFY), 0,8 / 0,9 / 0,9 mm, Table 1 column 7, with a wedge-shaped groove at least 0,3 mm deep in the middle of the web on both sides, 4.6; core colours DIN VDE 0293, 4.4).

1 sistema de codificación reconoce esta designación

Designaciones de tipo DIN VDE (Alemania)

SímboloSignificado
NTipo nacional alemán (VDE)
YAislamiento de conductores de PVC (YI 1)
IFStegleitung: conductor plano con alma, los conductores uno al lado de otro en una envoltura exterior común unida por un alma; sin otra letra la envoltura es de goma (NYIF)
YEnvoltura exterior de PVC (YM 1), NYIFY
NYIFNYIF / NYIFY: flat webbed installation wire (Stegleitung), PVC insulated solid copper cores side by side in an outer covering of rubber (NYIF) or PVC (NYIFY). U0/U 230/400 V (clause 3); for laying in and under plaster, DIN VDE 0298-3 (clause 6). DIN VDE 0250-201:1992-09 (2 and 3 cores 1,5 to 4 mm², 4 and 5 cores 1,5 and 2,5 mm², 4.1; bare solid copper class 1, 4.2; PVC insulation YI 1, 0,4 / 0,5 / 0,6 mm at 1,5 / 2,5 / 4 mm², 4.3 and Table 1 column 6; cores side by side, 4.5; outer covering vulcanised rubber (NYIF) or PVC YM 1 (NYIFY), 0,8 / 0,9 / 0,9 mm, Table 1 column 7, with a wedge-shaped groove at least 0,3 mm deep in the middle of the web on both sides, 4.6; core colours DIN VDE 0293, 4.4)

¿Qué es el cable NYIF?

NYIF: NYIF / NYIFY: flat webbed installation wire (Stegleitung), PVC insulated solid copper cores side by side in an outer covering of rubber (NYIF) or PVC (NYIFY). Valores nominales: U0/U 230/400 V (clause 3); for laying in and under plaster, DIN VDE 0298-3 (clause 6). Norma: DIN VDE 0250-201:1992-09 (2 and 3 cores 1,5 to 4 mm², 4 and 5 cores 1,5 and 2,5 mm², 4.1; bare solid copper class 1, 4.2; PVC insulation YI 1, 0,4 / 0,5 / 0,6 mm at 1,5 / 2,5 / 4 mm², 4.3 and Table 1 column 6; cores side by side, 4.5; outer covering vulcanised rubber (NYIF) or PVC YM 1 (NYIFY), 0,8 / 0,9 / 0,9 mm, Table 1 column 7, with a wedge-shaped groove at least 0,3 mm deep in the middle of the web on both sides, 4.6; core colours DIN VDE 0293, 4.4).

Documentos y páginas de los que se tomaron los datos

  • DIN VDE 0250-201:1992-09 (clauses 2 to 6 p. 2, Table 1 pp. 3 to 4)

Designaciones de tipo DIN VDE (Alemania): cómo leer los nombres de tipos de cable

Comportamiento frente al fuego (CPR europeo)

Una clase CPR la declara el fabricante en su declaración de prestaciones y se imprime en la cubierta (EN 50575 apdo. 7). Este descifrador no asigna ninguna. Qué significan las clases CPR →

Fuentes: borrador de la EN 13501-6 y borrador final FprEN 50575:2014 (borradores, no los textos publicados); IEC 60332-3-24:2000+A1:2008; borrador de la EN 13501-3 A2.

Tendido, secciones y ficha técnica: NYIF

Términos de esta página: calzo

Trabajar con NYIF

¿Quién fabrica o tiene en stock este cable?

Los fabricantes y distribuidores de esta familia de cables aparecen aquí como patrocinadores para su región, cada uno marcado como "Patrocinado"; un anuncio nunca cambia lo que esta página dice del cable.

Cables relacionados

Más designaciones Designaciones de tipo DIN VDE (Alemania)

NYIF