NYIF

NYIF is een kabelaanduiding volgens DIN VDE-typenamen (Duitsland): N = Duits nationaal type (VDE); Y = Aderisolatie van pvc (YI 1); IF = Stegleitung: platte draad met verbindingsstrook, de aders naast elkaar in een gemeenschappelijke buitenomhulling verbonden door een strook; zonder verdere letter is de omhulling van rubber (NYIF); Y = Buitenomhulling van pvc (YM 1), NYIFY; NYIF = NYIF / NYIFY: flat webbed installation wire (Stegleitung), PVC insulated solid copper cores side by side in an outer covering of rubber (NYIF) or PVC (NYIFY). U0/U 230/400 V (clause 3); for laying in and under plaster, DIN VDE 0298-3 (clause 6). DIN VDE 0250-201:1992-09 (2 and 3 cores 1,5 to 4 mm², 4 and 5 cores 1,5 and 2,5 mm², 4.1; bare solid copper class 1, 4.2; PVC insulation YI 1, 0,4 / 0,5 / 0,6 mm at 1,5 / 2,5 / 4 mm², 4.3 and Table 1 column 6; cores side by side, 4.5; outer covering vulcanised rubber (NYIF) or PVC YM 1 (NYIFY), 0,8 / 0,9 / 0,9 mm, Table 1 column 7, with a wedge-shaped groove at least 0,3 mm deep in the middle of the web on both sides, 4.6; core colours DIN VDE 0293, 4.4).

1 coderingssysteem herkent deze aanduiding

DIN VDE-typenamen (Duitsland)

SymboolBetekenis
NDuits nationaal type (VDE)
YAderisolatie van pvc (YI 1)
IFStegleitung: platte draad met verbindingsstrook, de aders naast elkaar in een gemeenschappelijke buitenomhulling verbonden door een strook; zonder verdere letter is de omhulling van rubber (NYIF)
YBuitenomhulling van pvc (YM 1), NYIFY
NYIFNYIF / NYIFY: flat webbed installation wire (Stegleitung), PVC insulated solid copper cores side by side in an outer covering of rubber (NYIF) or PVC (NYIFY). U0/U 230/400 V (clause 3); for laying in and under plaster, DIN VDE 0298-3 (clause 6). DIN VDE 0250-201:1992-09 (2 and 3 cores 1,5 to 4 mm², 4 and 5 cores 1,5 and 2,5 mm², 4.1; bare solid copper class 1, 4.2; PVC insulation YI 1, 0,4 / 0,5 / 0,6 mm at 1,5 / 2,5 / 4 mm², 4.3 and Table 1 column 6; cores side by side, 4.5; outer covering vulcanised rubber (NYIF) or PVC YM 1 (NYIFY), 0,8 / 0,9 / 0,9 mm, Table 1 column 7, with a wedge-shaped groove at least 0,3 mm deep in the middle of the web on both sides, 4.6; core colours DIN VDE 0293, 4.4)

Wat is de kabel NYIF?

NYIF: NYIF / NYIFY: flat webbed installation wire (Stegleitung), PVC insulated solid copper cores side by side in an outer covering of rubber (NYIF) or PVC (NYIFY). Nominale waarden: U0/U 230/400 V (clause 3); for laying in and under plaster, DIN VDE 0298-3 (clause 6). Norm: DIN VDE 0250-201:1992-09 (2 and 3 cores 1,5 to 4 mm², 4 and 5 cores 1,5 and 2,5 mm², 4.1; bare solid copper class 1, 4.2; PVC insulation YI 1, 0,4 / 0,5 / 0,6 mm at 1,5 / 2,5 / 4 mm², 4.3 and Table 1 column 6; cores side by side, 4.5; outer covering vulcanised rubber (NYIF) or PVC YM 1 (NYIFY), 0,8 / 0,9 / 0,9 mm, Table 1 column 7, with a wedge-shaped groove at least 0,3 mm deep in the middle of the web on both sides, 4.6; core colours DIN VDE 0293, 4.4).

Documenten en pagina's waaruit de gegevens komen

  • DIN VDE 0250-201:1992-09 (clauses 2 to 6 p. 2, Table 1 pp. 3 to 4)

DIN VDE-typenamen (Duitsland): kabeltypenamen lezen

Brandgedrag (EU-bouwproductenverordening, CPR)

Een CPR-klasse wordt door de fabrikant gedeclareerd in zijn prestatieverklaring en op de mantel afgedrukt (EN 50575 art. 7). Deze decoder kent geen klasse toe. Wat de CPR-klassen betekenen →

Bronnen: ontwerp EN 13501-6 en eindontwerp FprEN 50575:2014 (ontwerpen, niet de gepubliceerde teksten); IEC 60332-3-24:2000+A1:2008; ontwerp EN 13501-3 A2.

Leggen, doorsneden en datasheet: NYIF

Termen op deze pagina: wig (blokkeerwig)

Werken met NYIF

Wie maakt of heeft deze kabel op voorraad?

Fabrikanten en voorraadhouders van deze kabelfamilie verschijnen hier als sponsors voor uw regio, elk gemarkeerd als "Gesponsord"; een vermelding verandert nooit wat deze pagina over de kabel zegt.

Verwante kabels

Meer DIN VDE-typenamen (Duitsland) aanduidingen

NYIF