NYIF

NYIF er en kabelbetegnelse efter DIN VDE-typebetegnelser (Tyskland): N = Tysk national type (VDE); Y = Lederisolation af PVC (YI 1); IF = Stegleitung: flad ledning med kam, lederne side om side i en fælles yderkappe forbundet af en kam; uden yderligere bogstav er kappen af gummi (NYIF); Y = Yderkappe af PVC (YM 1), NYIFY; NYIF = NYIF / NYIFY: flat webbed installation wire (Stegleitung), PVC insulated solid copper cores side by side in an outer covering of rubber (NYIF) or PVC (NYIFY). U0/U 230/400 V (clause 3); for laying in and under plaster, DIN VDE 0298-3 (clause 6). DIN VDE 0250-201:1992-09 (2 and 3 cores 1,5 to 4 mm², 4 and 5 cores 1,5 and 2,5 mm², 4.1; bare solid copper class 1, 4.2; PVC insulation YI 1, 0,4 / 0,5 / 0,6 mm at 1,5 / 2,5 / 4 mm², 4.3 and Table 1 column 6; cores side by side, 4.5; outer covering vulcanised rubber (NYIF) or PVC YM 1 (NYIFY), 0,8 / 0,9 / 0,9 mm, Table 1 column 7, with a wedge-shaped groove at least 0,3 mm deep in the middle of the web on both sides, 4.6; core colours DIN VDE 0293, 4.4).

1 kodesystem genkender denne betegnelse

DIN VDE-typebetegnelser (Tyskland)

SymbolBetydning
NTysk national type (VDE)
YLederisolation af PVC (YI 1)
IFStegleitung: flad ledning med kam, lederne side om side i en fælles yderkappe forbundet af en kam; uden yderligere bogstav er kappen af gummi (NYIF)
YYderkappe af PVC (YM 1), NYIFY
NYIFNYIF / NYIFY: flat webbed installation wire (Stegleitung), PVC insulated solid copper cores side by side in an outer covering of rubber (NYIF) or PVC (NYIFY). U0/U 230/400 V (clause 3); for laying in and under plaster, DIN VDE 0298-3 (clause 6). DIN VDE 0250-201:1992-09 (2 and 3 cores 1,5 to 4 mm², 4 and 5 cores 1,5 and 2,5 mm², 4.1; bare solid copper class 1, 4.2; PVC insulation YI 1, 0,4 / 0,5 / 0,6 mm at 1,5 / 2,5 / 4 mm², 4.3 and Table 1 column 6; cores side by side, 4.5; outer covering vulcanised rubber (NYIF) or PVC YM 1 (NYIFY), 0,8 / 0,9 / 0,9 mm, Table 1 column 7, with a wedge-shaped groove at least 0,3 mm deep in the middle of the web on both sides, 4.6; core colours DIN VDE 0293, 4.4)

Hvad er kablet NYIF?

NYIF: NYIF / NYIFY: flat webbed installation wire (Stegleitung), PVC insulated solid copper cores side by side in an outer covering of rubber (NYIF) or PVC (NYIFY). Mærkedata: U0/U 230/400 V (clause 3); for laying in and under plaster, DIN VDE 0298-3 (clause 6). Standard: DIN VDE 0250-201:1992-09 (2 and 3 cores 1,5 to 4 mm², 4 and 5 cores 1,5 and 2,5 mm², 4.1; bare solid copper class 1, 4.2; PVC insulation YI 1, 0,4 / 0,5 / 0,6 mm at 1,5 / 2,5 / 4 mm², 4.3 and Table 1 column 6; cores side by side, 4.5; outer covering vulcanised rubber (NYIF) or PVC YM 1 (NYIFY), 0,8 / 0,9 / 0,9 mm, Table 1 column 7, with a wedge-shaped groove at least 0,3 mm deep in the middle of the web on both sides, 4.6; core colours DIN VDE 0293, 4.4).

Dokumenter og sider, som oplysningerne er hentet fra

  • DIN VDE 0250-201:1992-09 (clauses 2 to 6 p. 2, Table 1 pp. 3 to 4)

DIN VDE-typebetegnelser (Tyskland): sådan læser du kabeltypenavnene

Brandegenskaber (EU-byggevareforordningen, CPR)

En CPR-klasse deklareres af producenten i ydeevnedeklarationen og trykkes på kappen (EN 50575 pkt. 7). Denne afkoder tildeler ingen klasse. Hvad CPR-klasserne betyder →

Kilder: udkast til EN 13501-6 og slutudkast FprEN 50575:2014 (udkast, ikke de offentliggjorte tekster); IEC 60332-3-24:2000+A1:2008; udkast til EN 13501-3 A2.

Udlægning, tværsnit og datablad: NYIF

Termer på denne side: kile (stopklods)

Arbejd med NYIF

Hvem fremstiller eller lagerfører dette kabel?

Producenter og lagerførende af denne kabelfamilie vises her som sponsorer for din region, hver markeret "Sponsoreret"; en annonce ændrer aldrig, hvad denne side siger om kablet.

Beslægtede kabler

Flere DIN VDE-typebetegnelser (Tyskland) betegnelser

NYIF