N2XY
N2XY is a DIN VDE 0271/0276 power cables (Germany) cable designation: N = VDE Standard; 2X = Cross-Linked Polyethylene (XLPE); Y = Polyvinyl Chloride (PVC).
1 coding system recognises this code
Standard, worked reading and related types
Standards behind these values: IEC 60502-1:2004 (edition 2.0): Power cables with extruded insulation and their accessories for rated voltages from 1 kV (Um = 1,2 kV) up to 30 kV (Um = 36 kV) - Part 1: Cables for rated voltages of 1 kV (Um = 1,2 kV) and 3 kV (Um = 3,6 kV); IEC 60228:2023 (edition 4.0): Conductors of insulated cables. How the values are sourced
Worked reading of N2XY 3x16 0.6/1 kV:
N2XY: N = VDE Standard; 2X = Cross-Linked Polyethylene (XLPE); Y = Polyvinyl Chloride (PVC)3x16 0.6/1 kV: 3 cores, each copper 16 mm²; rated voltage 0.6/1 kV
Related cable types: RETFLEX N2XY · N2XRY · N2XH · NA2XY · A2XY · N2XSY
DIN VDE 0271/0276 power cables (Germany)
| Symbol | Meaning |
|---|---|
N | VDE Standard |
2X | Cross-Linked Polyethylene (XLPE) |
Y | Polyvinyl Chloride (PVC) |
How to read a DIN VDE 0271/0276 power cables (Germany) cable code
How to read a DIN VDE 0271/0276 power cables (Germany) cable code
A DIN VDE 0271/0276 power cables (Germany) designation (Germany) is a row of letter groups, and each group stands for one part of the cable: conductor, insulation, screen, armour, sheath, or the standard it follows. The decoder knows 51 symbols for this system.
What does N mean in a DIN VDE 0271/0276 power cables (Germany) cable code? N means VDE Standard.
What does 2X mean in a DIN VDE 0271/0276 power cables (Germany) cable code? 2X means Cross-Linked Polyethylene (XLPE).
What does Y mean in a DIN VDE 0271/0276 power cables (Germany) cable code? Y means Polyvinyl Chloride (PVC).
Fire behaviour (EU CPR)
PVC sheath (Y).
Typically targeted, as declared by makers for this kind of construction in the examples this site checked (not the class of this cable):
EcaN1XV-R, Ahlsell (seller)Cca-s3,d1,a3FG16OR16, Nexans (La Triveneta Cavi)EcaU1000 R2V, Nexans (La Triveneta Cavi)EcaN2XSY, Waskönig+Walter (10 kV datasheet)
Listed as sources, alphabetically by maker. No maker pays to appear here.
A CPR class is declared by the maker in its Declaration of Performance and printed on the sheath (EN 50575 cl 7). This decoder does not assign one. What the CPR classes mean →
Sources: EN 13501-6 draft and FprEN 50575:2014 final draft (drafts, not the published texts); IEC 60332-3-24:2000+A1:2008; EN 13501-3 draft A2.
N2XY dimensions and weight
- N2XY 4x1.5 0.6/1 kV
- N2XY 4x2.5 0.6/1 kV
- N2XY 4x4 0.6/1 kV
- N2XY 4x6 0.6/1 kV
- N2XY 4x10 0.6/1 kV
- N2XY 4x16 0.6/1 kV
- N2XY 4x25 0.6/1 kV
- N2XY 4x35 0.6/1 kV
- N2XY 4x50 SM 0.6/1 kV
- N2XY 4x70 SM 0.6/1 kV
- N2XY 4x95 SM 0.6/1 kV
- N2XY 4x120 SM 0.6/1 kV
- N2XY 4x150 SM 0.6/1 kV
- N2XY 4x185 SM 0.6/1 kV
- N2XY 4x240 SM 0.6/1 kV
- N2XY 3x1.5 0.6/1 kV
- N2XY 3x2.5 0.6/1 kV
- N2XY 3x4 0.6/1 kV
- N2XY 3x6 0.6/1 kV
- N2XY 3x10 0.6/1 kV
- N2XY 5x1.5 0.6/1 kV
- N2XY 5x2.5 0.6/1 kV
- N2XY 5x4 0.6/1 kV
- N2XY 5x6 0.6/1 kV
- N2XY 5x10 0.6/1 kV
- N2XY 1x50 0.6/1 kV
- N2XY 1x70 0.6/1 kV
- N2XY 1x95 0.6/1 kV
- N2XY 1x120 0.6/1 kV
- N2XY 1x150 0.6/1 kV
- N2XY 1x185 0.6/1 kV
- N2XY 1x240 0.6/1 kV
- N2XY 1x300 0.6/1 kV
N2XY: equivalents in other countries
Shown for 3x16 0.6/1 kV. Each country's rules are applied to this build, keeping the conductor, section, cores, voltage, screen, armour and sheath.
| Country | Standard | Name in that country | Verdict | Differences |
|---|---|---|---|---|
| International (IEC) | IEC 60502 | Cu/XLPE/PVC 3x16 0,6/1 kV (to IEC 60502-1) | Equivalent | every value the same |
| South Africa | SANS 1507-4 | no letters for this build | Close | Inner covering / bedding material: not in the equivalent; Overall diameter 19.17 → 17.17 mm |
| India | IS 7098 (Part 1) | 2XY 3x16 1100 V | Close | rated 0.635/1.1 kV (same Um 1.2 kV); Inner covering / bedding 1 → 0.3 mm; Overall diameter 19.17 → 17.77 mm |
No equivalent in: BS 5467 (armoured cables only); BS 6724 (armoured cables only, asks another sheath compound); BS 7846 (armoured cables only, asks another sheath compound).
Nominal values computed by each standard's rules, not manufacturer data. This is not a statement that two cables are interchangeable: the buyer's specification and the maker's type test decide.
N2XY as the cable designer builds it, 3x16 0.6/1 kV
Overall diameter 19.2 mm, about 710 kg/km. Nominal values from the standard's tables for this size, computed, not a maker's data.
| Layer | Material | Thickness, mm | Over the layer, mm |
|---|---|---|---|
| Insulation | XLPE | 0.70 | 6.3 |
| Filler | PP | 13.6 | |
| Inner covering / bedding | PVC | 1.0 | 15.6 |
| Sheath | PVC | 1.8 | 19.2 |
N2XY on a drum
The smallest drum that passes every check, for 19.2 mm and about 710 kg/km as the cable designer builds it. Drums as their makers print them; lengths are estimates: whole layers wound nested (each turn in the groove of the layer below), wound diameter 1.05 × OD, 50 mm freeboard under the flange rim. Cable makers' own tables print less, as they count aligned layers.
| Length | Drum size (its makers) | Layers | Gross weight |
|---|---|---|---|
| 500 m | KTG 10 (1000 mm flange), wood KTG drums (Europe), Bayka, KTG | 9 of 11 | 426–433 kg |
| 1,000 m | KTG 12 (1250 mm flange), wood KTG drums (Europe), Bayka, KTG | 12 of 14 | 854–875 kg |
Barrel at least 15 × OD = 288 mm for a cable of this kind (Low voltage, multi-core): KTG table, the cable's datasheet wins. A load rating is the drum maker's own. A steel drum whose maker prints none is checked against the DIN 46391-4 guide load instead: 28 kN per m³ of gross winding volume.
Other lengths, drums and weights: the cable drum calculator
Load it on a truck: 1000 m on its drum in the loading planner
Laying, sizes and datasheet: N2XY
N2XY belongs to the family LV XLPE power cables: the lowest laying temperature, bending radius, pulling, depth, drum handling and the test after laying, every rule with its sources. Laying and handling guide: LV XLPE power cables
Selling this cable? Open it in the designer and get a datasheet with your logo (Pro). Open the cable designer · See Pro
Work with N2XY
Who makes or stocks this cable?
Makers and stockists of this cable family appear here as sponsors for your region, each marked "Sponsored"; a listing never changes what this page says about the cable.