LIYCYH

LIYCYH is a VDE telecom, signal and fibre cables (DIN VDE 0815, 0816, 0813, 0888) cable designation: Li = Stranded Conductor, Flexible (Litzenleiter To VDE 0812); Y = Polyvinyl Chloride (PVC); C = Copper Screen As Braid; Y = Polyvinyl Chloride (PVC); H = Low Smoke Zero Halogen Compound.

2 coding systems recognise this code

Standard, worked reading and related types

Standards behind these values: HD 627 S1:1996/A2:2005: Multicore and multipair cables for installation above and below ground; IEC 60228:2023 (edition 4.0): Conductors of insulated cables. How the values are sourced

Worked reading of LIYCYH 4x0.5 500 V:

  • LIYCYH: Li = Stranded Conductor, Flexible (Litzenleiter To VDE 0812); Y = Polyvinyl Chloride (PVC); C = Copper Screen As Braid; Y = Polyvinyl Chloride (PVC); H = Low Smoke Zero Halogen Compound
  • 4x0.5 500 V: 4 cores, each copper 0.5 mm²; rated voltage peak500 kV

Related cable types: LiYCY-P · liycy · LiYCY-TP · LIHCH · LI2YCY · LIYY

VDE telecom, signal and fibre cables (DIN VDE 0815, 0816, 0813, 0888)

SymbolMeaning
LiStranded Conductor, Flexible (Litzenleiter To VDE 0812)
YPolyvinyl Chloride (PVC)
CCopper Screen As Braid
YPolyvinyl Chloride (PVC)
HLow Smoke Zero Halogen Compound

How to read a VDE telecom, signal and fibre cables (DIN VDE 0815, 0816, 0813, 0888) cable code

DIN VDE 0250 cords, control and special cables (Germany)

SymbolMeaning
LiEquipment Wire With Fine Stranded Conductor
YPolyvinyl Chloride (PVC); Control-Cable Key: Thermoplastics In General
CShielded
YPolyvinyl Chloride (PVC); Control-Cable Key: Thermoplastics In General
HHalogen-Free Compound (Insulation Or Sheath)

How to read a DIN VDE 0250 cords, control and special cables (Germany) cable code

How to read a VDE telecom, signal and fibre cables (DIN VDE 0815, 0816, 0813, 0888) cable code

A VDE telecom, signal and fibre cables (DIN VDE 0815, 0816, 0813, 0888) designation (Germany) is a row of letter groups, and each group stands for one part of the cable: conductor, insulation, screen, armour, sheath, or the standard it follows. The decoder knows 125 symbols for this system.

What does Li mean in a VDE telecom, signal and fibre cables (DIN VDE 0815, 0816, 0813, 0888) cable code? Li means Stranded Conductor, Flexible (Litzenleiter To VDE 0812).

What does Y mean in a VDE telecom, signal and fibre cables (DIN VDE 0815, 0816, 0813, 0888) cable code? Y means Polyvinyl Chloride (PVC).

What does C mean in a VDE telecom, signal and fibre cables (DIN VDE 0815, 0816, 0813, 0888) cable code? C means Copper Screen As Braid; or Jute Serving With Compound.

What does H mean in a VDE telecom, signal and fibre cables (DIN VDE 0815, 0816, 0813, 0888) cable code? H means Low Smoke Zero Halogen Compound.

Fire behaviour (EU CPR)

  • Halogen-free compound (H). Under the CPR this shows in the additional classes: acidity a1 to a3 (EN 60754-2) and smoke s1 to s3 (EN 50399; s1a and s1b add the 3 m cube test EN 61034-2). The main class, Aca to Fca, depends on the whole construction.

    Typically targeted, as declared by makers for this kind of construction in the examples this site checked (not the class of this cable):

    Listed as sources, alphabetically by maker. No maker pays to appear here.

A CPR class is declared by the maker in its Declaration of Performance and printed on the sheath (EN 50575 cl 7). This decoder does not assign one. What the CPR classes mean →

Sources: EN 13501-6 draft and FprEN 50575:2014 final draft (drafts, not the published texts); IEC 60332-3-24:2000+A1:2008; EN 13501-3 draft A2.

LIYCYH as the cable designer builds it, 4x0.5 500 V

Overall diameter 6.2 mm, about 60 kg/km. Nominal values from the standard's tables for this size, computed, not a maker's data.

LayerMaterialThickness, mmOver the layer, mm
InsulationPVC0.451.8
Separation tapePolyester0.054.4
Braid (copper wires)Copper0.204.8
SheathHalogen-free (LSZH)0.706.2

LIYCYH on a drum

The smallest drum that passes every check, for 6.2 mm and about 60 kg/km as the cable designer builds it. Drums as their makers print them; lengths are estimates: whole layers wound nested (each turn in the groove of the layer below), wound diameter 1.05 × OD, 50 mm freeboard under the flange rim. Cable makers' own tables print less, as they count aligned layers.

LengthDrum size (its makers)LayersGross weight
500 mKTG 3 (390 mm flange), plastic KTG drums (Europe), KTG13 of 1432 kg
1,000 mKTG 5 (500 mm flange), plastic KTG drums (Europe), Bayka, KTG20 of 2163–64 kg

Barrel at least 20 × OD = 125 mm for a cable of this kind (Telecom, data and control cable): KTG table, the cable's datasheet wins. A load rating is the drum maker's own. A steel drum whose maker prints none is checked against the DIN 46391-4 guide load instead: 28 kN per m³ of gross winding volume.

Other lengths, drums and weights: the cable drum calculator

Load it on a truck: 1000 m on its drum in the loading planner

Laying, sizes and datasheet: LIYCYH

LIYCYH belongs to the family Control and instrument cables: the lowest laying temperature, bending radius, pulling, depth, drum handling and the test after laying, every rule with its sources. Laying and handling guide: Control and instrument cables

Selling this cable? Open it in the designer and get a datasheet with your logo (Pro). Open the cable designer · See Pro

Work with LIYCYH

Who makes or stocks this cable?

Makers and stockists of this cable family appear here as sponsors for your region, each marked "Sponsored"; a listing never changes what this page says about the cable.

LIYCYH compared

Related cables

More VDE telecom, signal and fibre cables (DIN VDE 0815, 0816, 0813, 0888) designations