LiYDY
LiYDY is a VDE telecom, signal and fibre cables (DIN VDE 0815, 0816, 0813, 0888) cable designation: Li = Stranded Conductor, Flexible (Litzenleiter To VDE 0812); Y = Polyvinyl Chloride (PVC); D = Copper Wire Screen, Helically Applied (Copper Serving); Y = Polyvinyl Chloride (PVC).
2 coding systems recognise this code
Standard, worked reading and related types
Worked reading of LiYDY:
LiYDY: Li = Stranded Conductor, Flexible (Litzenleiter To VDE 0812); Y = Polyvinyl Chloride (PVC); D = Copper Wire Screen, Helically Applied (Copper Serving); Y = Polyvinyl Chloride (PVC)
VDE telecom, signal and fibre cables (DIN VDE 0815, 0816, 0813, 0888)
| Symbol | Meaning |
|---|---|
Li | Stranded Conductor, Flexible (Litzenleiter To VDE 0812) |
Y | Polyvinyl Chloride (PVC) |
D | Copper Wire Screen, Helically Applied (Copper Serving) |
Y | Polyvinyl Chloride (PVC) |
How to read a VDE telecom, signal and fibre cables (DIN VDE 0815, 0816, 0813, 0888) cable code
DIN VDE 0250 cords, control and special cables (Germany)
| Symbol | Meaning |
|---|---|
Li | Equipment Wire With Fine Stranded Conductor |
Y | Polyvinyl Chloride (PVC); Control-Cable Key: Thermoplastics In General |
D | Solid Wire |
Y | Polyvinyl Chloride (PVC); Control-Cable Key: Thermoplastics In General |
How to read a DIN VDE 0250 cords, control and special cables (Germany) cable code
How to read a VDE telecom, signal and fibre cables (DIN VDE 0815, 0816, 0813, 0888) cable code
A VDE telecom, signal and fibre cables (DIN VDE 0815, 0816, 0813, 0888) designation (Germany) is a row of letter groups, and each group stands for one part of the cable: conductor, insulation, screen, armour, sheath, or the standard it follows. The decoder knows 125 symbols for this system.
What does Li mean in a VDE telecom, signal and fibre cables (DIN VDE 0815, 0816, 0813, 0888) cable code? Li means Stranded Conductor, Flexible (Litzenleiter To VDE 0812).
What does Y mean in a VDE telecom, signal and fibre cables (DIN VDE 0815, 0816, 0813, 0888) cable code? Y means Polyvinyl Chloride (PVC).
What does D mean in a VDE telecom, signal and fibre cables (DIN VDE 0815, 0816, 0813, 0888) cable code? D means Loose Tube, Filled; or Copper Wire Screen, Helically Applied (Copper Serving).
Fire behaviour (EU CPR)
PVC sheath (Y).
Typically targeted, as declared by makers for this kind of construction in the examples this site checked (not the class of this cable):
EcaN1XV-R, Ahlsell (seller)Cca-s3,d1,a3FG16OR16, Nexans (La Triveneta Cavi)EcaU1000 R2V, Nexans (La Triveneta Cavi)EcaN2XSY, Waskönig+Walter (10 kV datasheet)
Listed as sources, alphabetically by maker. No maker pays to appear here.
A CPR class is declared by the maker in its Declaration of Performance and printed on the sheath (EN 50575 cl 7). This decoder does not assign one. What the CPR classes mean →
Sources: EN 13501-6 draft and FprEN 50575:2014 final draft (drafts, not the published texts); IEC 60332-3-24:2000+A1:2008; EN 13501-3 draft A2.
Work with LiYDY
Who makes or stocks this cable?
Makers and stockists of this cable family appear here as sponsors for your region, each marked "Sponsored"; a listing never changes what this page says about the cable.
Related cables
More VDE telecom, signal and fibre cables (DIN VDE 0815, 0816, 0813, 0888) designations