AY
AY is a CSN (Czech Republic, Slovakia) cable designation: A = Aluminium conductor; Y = PVC insulation, normal type; AY = AY: single-core aluminium wire, PVC insulation, for fixed installation in conduits and boards, not for direct burial. 450/750 V. PN-NKT-107-13 (NKT).
3 coding systems recognise this code
Standard, worked reading and related types
Worked reading of AY:
AY: A = Aluminium conductor; Y = PVC insulation, normal type; AY = AY: single-core aluminium wire, PVC insulation, for fixed installation in conduits and boards, not for direct burial. 450/750 V. PN-NKT-107-13 (NKT)
CSN (Czech Republic, Slovakia)
| Symbol | Meaning |
|---|---|
A | Aluminium conductor |
Y | PVC insulation, normal type |
AY | AY: single-core aluminium wire, PVC insulation, for fixed installation in conduits and boards, not for direct burial. 450/750 V. PN-NKT-107-13 (NKT) |
Romania (STAS 9436 national symbols)
| Symbol | Meaning |
|---|---|
A | Aluminium Conductor |
Y | Polyvinyl Chloride (PVC) Insulation, Sheath Or Outer Covering |
How to read a Romania (STAS 9436 national symbols) cable code
India (IS 1554 / IS 7098 cable code)
| Symbol | Meaning |
|---|---|
A | Aluminium Conductor |
Y | Polyvinyl Chloride (PVC) |
How to read a India (IS 1554 / IS 7098 cable code) cable code
What is AY cable?
AY: single-core aluminium wire, PVC insulation, for fixed installation in conduits and boards, not for direct burial. Rating: 450/750 V. Standard: PN-NKT-107-13 (NKT).
No size in the code.
Documents and pages the readings were taken from
CSN (Czech Republic, Slovakia): how to read the cable type names
Fire behaviour (EU CPR)
PVC sheath (AY).
Typically targeted, as declared by makers for this kind of construction in the examples this site checked (not the class of this cable):
EcaN1XV-R, Ahlsell (seller)Cca-s3,d1,a3FG16OR16, Nexans (La Triveneta Cavi)EcaU1000 R2V, Nexans (La Triveneta Cavi)EcaN2XSY, Waskönig+Walter (10 kV datasheet)
Listed as sources, alphabetically by maker. No maker pays to appear here.
A CPR class is declared by the maker in its Declaration of Performance and printed on the sheath (EN 50575 cl 7). This decoder does not assign one. What the CPR classes mean →
Sources: EN 13501-6 draft and FprEN 50575:2014 final draft (drafts, not the published texts); IEC 60332-3-24:2000+A1:2008; EN 13501-3 draft A2.
Laying, sizes and datasheet: AY
Terms on this page: conduit · direct burial
Work with AY
Who makes or stocks this cable?
Makers and stockists of this cable family appear here as sponsors for your region, each marked "Sponsored"; a listing never changes what this page says about the cable.