Each name in CSN (Czech Republic, Slovakia) stands for a whole cable type: CYY, for example, comes with its own construction, standard and rating. The decoder knows 30 types of this system. Below: how the names are built, every type with its rating, and the sources the table names.
How a name is built
The type table splits each name into parts and records what each part means. A few names taken apart:
CYY
| C | Copper conductor |
| Y | PVC insulation |
| Y | Additional PVC insulation |
CYY: single-core solid copper wire with a second PVC insulation layer, only for screening and signal purposes, 450/750 V
1-CYKY
| C | Copper conductor |
| Y | PVC insulation, normal type |
| K | kabel: a cable proper, for fixed installation |
| Y | PVC sheath |
| 1- | Voltage-class prefix: 1 = 0,6/1 kV (no prefix: 450/750 V) |
1-CYKY: copper power cable, PVC insulation and PVC sheath, 0,6/1 kV, 3 to 5 cores, 25 to 240 mm2 (= NYY)
CYKY
| C | Copper conductor |
| Y | PVC insulation, normal type |
| K | kabel: a cable proper, for fixed installation |
| Y | PVC sheath |
CYKY: copper installation cable, PVC insulation and PVC sheath, 450/750 V, 2 to 48 cores (no European equivalent per NKT; do not read it as NYM-J)
AYKY
| A | Aluminium conductor |
| Y | PVC insulation, normal type |
| K | kabel: a cable proper, for fixed installation |
| Y | PVC sheath |
AYKY: aluminium installation cable, PVC insulation and PVC sheath, 450/750 V (listed with the NKT aluminium-core cables)
Every part used in the names
| Part | Meaning | Used in |
|---|---|---|
| C | Copper conductor | CYKY 1-CYKY CYKYLO CYKYZ CYKYDY 1-CYKYDY 1-CYKFY CY CYA CYY CYSY CYLY CYH CGSG CGTG CMSM CMFM 1-CXKH-R 1-CHKE-R 1-CXKH-V 1-CHKE-V |
| Y | PVC insulation, normal type | CYKY 1-CYKY AYKY 1-AYKY CYKYLO CYKYZ AYKYZ 1-AYKYZ CYKYDY 1-CYKYDY 1-CYKFY CY AY CYA CYSY CYLY CYH |
| K | kabel: a cable proper, for fixed installation | CYKY 1-CYKY AYKY 1-AYKY CYKYLO CYKYZ AYKYZ 1-AYKYZ CYKYDY 1-CYKYDY 1-CYKFY 1-CXKH-R 1-CHKE-R 1-CXKH-V 1-CHKE-V |
| Y | PVC sheath | CYKY 1-CYKY AYKY 1-AYKY CYKYLO CYKYZ AYKYZ 1-AYKYZ 1-CYKFY CYSY CYLY JYTY SYKFY |
| 1- | Voltage-class prefix: 1 = 0,6/1 kV | 1-AYKY 1-CYKYDY 1-CYKFY 1-CXKH-R 1-CHKE-R 1-CXKH-V 1-CHKE-V |
| A | Aluminium conductor | AYKY 1-AYKY AYKYZ 1-AYKYZ AY |
| S | Medium cord (stredni snura) | CYSY CGSG CMSM CMFM |
| Z | Suspended cable: the sheath carries a steel carrier rope (CYKYz: 1x1,06 + 6x1 mm, 6,56 kN) | CYKYZ AYKYZ 1-AYKYZ |
| Y | PVC insulation | CYY JYTY SYKFY |
| Y | PVC sheath under the armour | CYKYDY 1-CYKYDY |
| D | Armour of galvanised steel wires (CSN 34 7401 position 6) | CYKYDY 1-CYKYDY |
| Y | PVC protective cover over the armour | CYKYDY 1-CYKYDY |
| G | Rubber insulation, normal type | CGSG CGTG |
| G | Rubber sheath | CGSG CGTG |
| M | PVC, frost-resistant | CMSM CMFM |
| M | PVC, frost-resistant, oil and petrol resistant sheath | CMSM CMFM |
| X | Cross-linked halogen-free insulation (X = cross-linked PE letter, family reading) | 1-CXKH-R 1-CXKH-V |
| H | Halogen-free sheath (H, DIN VDE 0815 style letter) | 1-CXKH-R 1-CXKH-V |
| H | Halogen-free insulation (H, DIN VDE 0815 style letter; family reading) | 1-CHKE-R 1-CHKE-V |
| E | Halogen-free sheath: E in the sheath slot is by family equivalence, not stated letter by letter (UNVERIFIED letter) | 1-CHKE-R 1-CHKE-V |
| 1- | Voltage-class prefix: 1 = 0,6/1 kV (no prefix: 450/750 V) | 1-CYKY |
| Lo | Bridge (flat) version (CVUT: M = bridged wire; VSB: "Lo = mustkove provedeni, plochy kabel") | CYKYLO |
| F | Metallic covering (braid, wire or tape); the metal is not stated | 1-CYKFY |
| A | Round (kulaty) conductor; the stranded flexible nature comes from the H05(7)V-K pairing (table only) | CYA |
| Y | Additional PVC insulation | CYY |
| L | Light cord (lehka snura): not "stranded" | CYLY |
| H | Flat cord (plocha snura) | CYH |
| T | Heavy cord (tezka snura) | CGTG |
| F | Metallic screen (braid, wire or tape); the metal is not stated | CMFM |
| J | Installation cable (DIN VDE 0815 style per Lapp; UNVERIFIED for this Czech type) | JYTY |
| T | UNVERIFIED: no fetched source explains the T | JYTY |
| S | UNVERIFIED: not explained by a Czech source (Lapp: S = patch / connecting cable in DIN) | SYKFY |
| K | UNVERIFIED: Lapp lists (K) = copper-tape screen, which does not settle the letter here | SYKFY |
| F | UNVERIFIED: Lapp lists F = petrolatum filling, which contradicts the real foil screen of the product | SYKFY |
| J | UNVERIFIED: no fetched source decodes the letters of JXFE-R (DIN style: J = installation cable) | JXFE-R |
| X | UNVERIFIED: no fetched source decodes this letter for this type | JXFE-R |
| F | UNVERIFIED: no fetched source decodes this letter for this type | JXFE-R |
| E | UNVERIFIED: no fetched source decodes this letter for this type | JXFE-R |
| 22- | Voltage-class prefix: 22 = 12,7/22 kV (Jmenovité napětí Uo/U 12.7/22) | 22-CXEKCY |
| C | Copper conductor (Měděné jádro) | 22-CXEKCY |
| X | Cross-linked polyethylene insulation (Izolace ze zesítěného polyetylenu) | 22-CXEKCY |
| E | Extruded semiconducting layers (vytlačovaná polovodivá vrstva); inferred from the layer list, key not printed | 22-CXEKCY |
| K | kabel: a cable proper, for fixed installation (pevné uložení) | 22-CXEKCY |
| C | Copper screen: wires with copper-tape counter-helix (Stínění měděnými dráty s protispirálou) | 22-CXEKCY |
| Y | PVC sheath (Vnější PVC plášť) | 22-CXEKCY |
What the type table says about the names
Quoted from the notes of the type table, with the types they belong to.
- -J / -O after the name says with / without the green-yellow core; CYKY is sold -J by default. (CYKY)
- Counts: 4J1,5, 4Bx1,5 and 4-J all mean 4 cores including a green-yellow one; the B / C / D letters after a count are colour-scheme codes of the old CSN 33 0165 table, not a "without protective core" flag. (CYKY, 1-CYKY, AYKY, 1-AYKY, CYKYLO, CYKYZ +5)
- Cords write the earth core as 3G1,5 (with) and 2Xx0,5 (without) instead of -J / -O. (CYSY, CYLY, CYH, CGSG, CGTG)
- Two-letter code: conductor and insulation only, no design letter and no sheath. (CY)
- ELF writes the whole family as "1-C(X-H)K(E-H)-R" (X or H in the insulation slot, E or H in the sheath slot): 1-CXKH-R, 1-CHKE-R, 1-CXKE-R and 1-CHKH-R are spellings of one halogen-free construction. (1-CXKH-R, 1-CHKE-R, 1-CXKH-V, 1-CHKE-V)
Every type in CSN (Czech Republic, Slovakia)
| Type | Description | Rating |
|---|---|---|
CYKY | CYKY: copper installation cable, PVC insulation and PVC sheath, 450/750 V, 2 to 48 cores (no European equivalent per NKT; do not read it as NYM-J) | 450/750 V |
1-CYKY | 1-CYKY: copper power cable, PVC insulation and PVC sheath, 0,6/1 kV, 3 to 5 cores, 25 to 240 mm2 (= NYY) | 0,6/1 kV |
AYKY | AYKY: aluminium installation cable, PVC insulation and PVC sheath, 450/750 V (listed with the NKT aluminium-core cables) | 450/750 V |
1-AYKY | 1-AYKY: aluminium power cable, PVC insulation and PVC sheath, 0,6/1 kV, 3 to 5 cores (= NAYY) | 0,6/1 kV |
CYKYLO | CYKYLo: flat (bridge) copper installation cable for plaster and conduits, PVC insulation and PVC sheath, 2 to 3 cores, no bedding, 450/750 V | 450/750 V |
CYKYZ | CYKYz: copper installation cable like CYKY with a steel carrier rope in the sheath, for overhead spans, 450/750 V | 450/750 V |
AYKYZ | AYKYz: aluminium installation cable like AYKY with a steel carrier rope in the sheath, for overhead spans | 450/750 V |
1-AYKYZ | 1-AYKYz: aluminium power cable, 0,6/1 kV, with a steel carrier rope in the sheath (NKT lists 4x10 to 4x35 for overhead use) | 0,6/1 kV |
CYKYDY | CYKYDY: copper cable with galvanised steel wire armour and a PVC cover, 450/750 V (2x1,5 to 5x16) | 450/750 V |
1-CYKYDY | 1-CYKYDY: copper power cable, PVC, steel wire armour and PVC cover, 0,6/1 kV, 3x25 to 5x120 | 0,6/1 kV |
1-CYKFY | 1-CYKFY: copper power cable with a metallic screen (F), PVC, 0,6/1 kV (screened cables, listed beside NYCY / NYCWY) | 0,6/1 kV |
CY | CY: single-core solid copper wire, PVC insulation, no sheath (= H05V-U / H07V-U) | 300/500 V (H05V-U) and 450/750 V (H07V-U) |
AY | AY: single-core aluminium wire, PVC insulation, for fixed installation in conduits and boards, not for direct burial | 450/750 V |
CYA | CYA: single-core flexible stranded copper wire, PVC insulation, no sheath (= H05V-K / H07V-K) | 300/500 V (H05V-K) and 450/750 V (H07V-K) |
CYY | CYY: single-core solid copper wire with a second PVC insulation layer, only for screening and signal purposes, 450/750 V | 450/750 V |
CYSY | CYSY: round medium cord, copper, PVC / PVC, 300/500 V (= H05VV-F, also H03VV-F and H05VVH2-F) | 300/500 V |
CYLY | CYLY: round light cord, copper, PVC / PVC, 300/300 V (= H03VV-F; printed variants V03VV-F, H03VVH2-F) | 300/300 V |
CYH | CYH: flat twin cord (plocha snura), copper, PVC, no outer sheath, 300/300 V (= V03VH-H) | 300/300 V |
CGSG | CGSG: round medium cord, copper (tinned per ELF), rubber / rubber, 300/500 V (= H05RR-F) | 300/500 V |
CGTG | CGTG: round heavy cord, tinned copper, rubber / rubber (chloroprene sheath per makers), 450/750 V (= H07RN-F) | 450/750 V |
CMSM | CMSM: flexible machine lead, copper, frost-resistant PVC / PVC, 300/500 V, 2 to 37 cores, numbered cores (= YSLY-JZ with PE, YSLY-OZ without) | 300/500 V |
CMFM | CMFM: screened flexible machine lead, copper, frost-resistant PVC / PVC, 300/500 V, numbered cores (= YSLCY-JZ, YCY-JZ) | 300/500 V |
1-CXKH-R | 1-CXKH-R: copper power cable, cross-linked halogen-free insulation, flame-retarding halogen-free sheath (-R: no function in fire), 0,6/1 kV (= N2XH) | 0,6/1 kV |
1-CHKE-R | 1-CHKE-R: copper power cable, cross-linked halogen-free insulation, HFFR bedding and sheath, flame-retarding (-R), 0,6/1 kV (= N2XH) | 0,6/1 kV |
1-CXKH-V | 1-CXKH-V: copper power cable with circuit integrity in fire (-V), cross-linked halogen-free insulation and sheath, 0,6/1 kV (= NHXH-FE180/E30-E90) | 0,6/1 kV |
1-CHKE-V | 1-CHKE-V: copper power cable with circuit integrity in fire (-V), halogen-free insulation, bedding and sheath, 0,6/1 kV, E30 to E90 (= NHXH-FE180/E30-E90) | 0,6/1 kV |
JYTY | JYTY: PVC / PVC industrial control cable, solid copper cores 1,0 mm, plastic foil and laminated aluminium foil screen with copper drain wire, grey PVC sheath, 250 V | 250 V (1,0 mm core), -30 to +85 C |
SYKFY | SYKFY: screened communication cable for fixed indoor wiring, 2 to 100 pairs x 2 x 0,5 mm, PVC, 100 V | 100 V |
JXFE-R | JXFE-R: halogen-free flame-retardant screened communication cable, pairs 2 x 0,5 to 0,8 mm, 100 V (= SHKFH-R) | 100 V |
22-CXEKCY | 22-CXEKCY: single-core 22 kV cable, copper conductor, XLPE insulation, extruded semiconducting layers, copper wire screen with copper-tape counter-helix, PVC sheath, 12,7/22 kV | 12,7/22 kV (max 25 kV), 90 C |
Marks written next to the name
Words and marks the decoder reads next to a type name of this system: each adds a property to whatever type it is written with.
| Mark | Meaning | Written as |
|---|---|---|
| -J | With a green-yellow protective core (written J, (J) or inside the count: 4J1,5) | -J (J) |
| -O | Without a green-yellow protective core (ohne) | -O |
| RE | Conductor shape: round, solid | RE |
| RM | Conductor shape: round, stranded | RM |
| SE | Conductor shape: sector, solid | SE |
| SM | Conductor shape: sector, stranded | SM |
| -R | Flame-retarding halogen-free cable, no function in fire (ohen retardujici) | -R |
| -V | Circuit integrity in fire (funkcni schopnost pri pozaru); the class E30 / E60 / E90 or P30 / P60 / P90 follows | -V |
| E30 | Circuit integrity 30 minutes (DIN 4102-12) | E30 |
| E60 | Circuit integrity 60 minutes (DIN 4102-12) | E60 |
| E90 | Circuit integrity 90 minutes (DIN 4102-12) | E90 |
| P30-R | Circuit integrity 30 minutes (Czech ZP 27/2008), -R: flame-retarding | P30-R |
| P60-R | Circuit integrity 60 minutes (Czech ZP 27/2008), -R: flame-retarding | P60-R |
| P90-R | Circuit integrity 90 minutes (Czech ZP 27/2008), -R: flame-retarding | P90-R |
| FE180 | Insulation integrity 180 minutes | FE180 |
| B2ca | CPR reaction-to-fire class B2ca; the sub-classes s1, d0 (and a1) are printed after it | B2CA |
Common questions
What is CYY cable?
CYY: single-core solid copper wire with a second PVC insulation layer, only for screening and signal purposes, 450/750 V. Rating: 450/750 V. Standard: PN-KT-081-09 (NKT). The name reads: C (Copper conductor) + Y (PVC insulation) + Y (Additional PVC insulation).
What is 1-CYKY cable?
1-CYKY: copper power cable, PVC insulation and PVC sheath, 0,6/1 kV, 3 to 5 cores, 25 to 240 mm2 (= NYY). Rating: 0,6/1 kV. Standard: TP-KK-133/01 (NKT). The name reads: C (Copper conductor) + Y (PVC insulation, normal type) + K (kabel: a cable proper, for fixed installation) + Y (PVC sheath) + 1- (Voltage-class prefix: 1 = 0,6/1 kV (no prefix: 450/750 V)).
What is the difference between 1-CYKY and CYKY?
1-CYKY: copper power cable, PVC insulation and PVC sheath, 0,6/1 kV, 3 to 5 cores, 25 to 240 mm2 (= NYY), 0,6/1 kV. CYKY: copper installation cable, PVC insulation and PVC sheath, 450/750 V, 2 to 48 cores (no European equivalent per NKT; do not read it as NYM-J), 450/750 V. The names differ in: 1-CYKY: 1- (Voltage-class prefix: 1 = 0,6/1 kV (no prefix: 450/750 V)).
CSN (Czech Republic, Slovakia): what does C mean in a cable name?
C has more than one meaning, depending on the type: Copper conductor (CYKY, 1-CYKY, CYKYLO, CYKYZ +17); Copper conductor (Měděné jádro) (22-CXEKCY); Copper screen: wires with copper-tape counter-helix (Stínění měděnými dráty s protispirálou) (22-CXEKCY).
CSN (Czech Republic, Slovakia): what does -J mean next to a cable name?
-J: With a green-yellow protective core (written J, (J) or inside the count: 4J1,5). Written as -J, (J).
What is CYKY cable?
CYKY: copper installation cable, PVC insulation and PVC sheath, 450/750 V, 2 to 48 cores (no European equivalent per NKT; do not read it as NYM-J). Rating: 450/750 V. Standard: TP-KK-134/01 (NKT); TP PRAKAB 01/03 (Prakab). The name reads: C (Copper conductor) + Y (PVC insulation, normal type) + K (kabel: a cable proper, for fixed installation) + Y (PVC sheath).
Sources the type table names
Standards named in the table
- TP-KK-134/01 (NKT)
- TP PRAKAB 01/03 (Prakab)
- TP-KK-133/01 (NKT)
- PN-KV-062-00 (NKT CYKYLo)
- TP-KK-133/01 (NKT CYKYz)
- TP-KK-133/01 (NKT family)
- TP-KK-020/96 (NKT 1-AYKYz)
- not stated by the sources read (NKT programme, "stinene" screened cables)
- harmonised type H05(7)V-U (CSN 34 7409 alias)
- PN-NKT-107-13 (NKT)
- harmonised type H05(7)V-K (CSN 34 7409 alias)
- PN-KT-081-09 (NKT)
- harmonised type H05VV-F (CSN 34 7409 alias)
- harmonised type H03VV-F (CSN 34 7409 alias)
- harmonised type V03VH-H (CSN 34 7409 alias)
- harmonised type H05RR-F (CSN 34 7409 alias)
- harmonised type H07RN-F (CSN 34 7409 alias)
- PN-KV-072-03 (NKT)
- TP 07/11 (Kablo Vrchlabi)
- TP-NKT 03/09 (NKT NOPOVIC)
- class B2ca-s1,d0,a1
- PN-KV-073-03 (NKT 1-CHKE-R)
- class B2ca-s1
- TP-NKT 04/09 (family, per the shop listing)
- circuit integrity E30 to E90 / P30 to P90
- TP-KK-147/03 (NKT 1-CHKE-V)
- TP PRAKAB 04/03
- CSN letter code (communication cable)
- no standard number named by the sources read
- Kablo Vrchlabi halogen-free communication cable
- PN 05/96 (NKT datasheet)
- PNE 34 7625 (Labara Cables)
Documents and pages the readings were taken from
- pslib.cz/ivo.petricek/prezentace/vyuka_EEN/3_rocnik/vodice/nkt.pdf
- ielektra.cz/static/_user/uploads/stahuj/katalog-prakab-2023.bm6ao.pdf
- pslib.cz/ivo.petricek/prezentace/vyuka_EEN/3_rocnik/vodice/nkt_vyrobni_…
- indprop.gov.sk/rozhodnutia/dokumenty/oz/2015/OZ_2015-62_1616-2013.pdf
- tzb.fsv.cvut.cz/files/znaceni_vodicu_a_kabelu_podekovani.pdf
- elfetex.cz/media/wysiwyg/2_-_P_ehled_kabel_a_vodi_10.1._2018.pdf
- preshranice22.vsb.cz/5_kabely_vodice_ulozeni.pdf
- zbozi.cz
- moodle.it.pedf.cuni.cz/pluginfile.php/171068/mod_resource/content/2/III…
- zbozi.cz
- zbozi.cz
- zbozi.cz
- zbozi.cz/vyrobek/draka-cysy-h05vv-f-3-x-1-mm2-metraz
- zbozi.cz
- zbozi.cz
- zbozi.cz
- zbozi.cz
- zbozi.cz/vyrobek/tele-fonika-h07rn-f-5g4-cgtg
- zbozi.cz
- emas.cz/files/1889749/2MdSrvYP/elkaos1228025.pdf
- pslib.cz/ivo.petricek/prezentace/vyuka_ZAE/katalog/Bezhalogenove_vodice…
- zbozi.cz
- zbozi.cz
- t3.lappcdn.com/fileadmin/catalog/cz_T_pdf/T6_Typové_zkratky_cz.pdf
- zbozi.cz
- zbozi.cz
- zbozi.cz
- nkt.widen.net/content/wifejev8gs/pdf/22-CXEKCYDSCZENMV_MV_DS_CS-EN.pdf
- labaracables.cz/en
Taken from the type table of this site, with the sources named above. Check the manufacturer's datasheet before you specify a cable.
Every type in CSN (Czech Republic, Slovakia) · Decode your own designation