AYKYZ

AYKYZ is a CSN (Czech Republic, Slovakia) cable designation: A = Aluminium conductor; Y = PVC insulation, normal type; K = kabel: a cable proper, for fixed installation; Y = PVC sheath; Z = Suspended cable: the sheath carries a steel carrier rope (CYKYz: 1x1,06 + 6x1 mm, 6,56 kN); AYKYZ = AYKYz: aluminium installation cable like AYKY with a steel carrier rope in the sheath, for overhead spans. 450/750 V. TP-KK-133/01 (NKT family).

1 coding system recognises this code

Standard, worked reading and related types

Worked reading of AYKYZ:

  • AYKYZ: A = Aluminium conductor; Y = PVC insulation, normal type; K = kabel: a cable proper, for fixed installation; Y = PVC sheath; Z = Suspended cable: the sheath carries a steel carrier rope (CYKYz: 1x1,06 + 6x1 mm, 6,56 kN); AYKYZ = AYKYz: aluminium installation cable like AYKY with a steel carrier rope in the sheath, for overhead spans. 450/750 V. TP-KK-133/01 (NKT family)

Related cable types: 1-AYKYZ · AYKY · CYKYZ

CSN (Czech Republic, Slovakia)

SymbolMeaning
AAluminium conductor
YPVC insulation, normal type
Kkabel: a cable proper, for fixed installation
YPVC sheath
ZSuspended cable: the sheath carries a steel carrier rope (CYKYz: 1x1,06 + 6x1 mm, 6,56 kN)
AYKYZAYKYz: aluminium installation cable like AYKY with a steel carrier rope in the sheath, for overhead spans. 450/750 V. TP-KK-133/01 (NKT family)

What is AYKYZ cable?

AYKYZ: AYKYz: aluminium installation cable like AYKY with a steel carrier rope in the sheath, for overhead spans. Rating: 450/750 V. Standard: TP-KK-133/01 (NKT family).

Printed AYKYz or AYKYZ. The standard shown is the one printed for the NKT CYKYz twin; no AYKYz sheet was read. Counts: 4J1,5, 4Bx1,5 and 4-J all mean 4 cores including a green-yellow one; the B / C / D letters after a count are colour-scheme codes of the old CSN 33 0165 table, not a "without protective core" flag. 3x150+70 is three 150 mm2 cores plus one smaller 70 mm2 core (PE or PEN).

Documents and pages the readings were taken from

CSN (Czech Republic, Slovakia): how to read the cable type names

Fire behaviour (EU CPR)

A CPR class is declared by the maker in its Declaration of Performance and printed on the sheath (EN 50575 cl 7). This decoder does not assign one. What the CPR classes mean →

Sources: EN 13501-6 draft and FprEN 50575:2014 final draft (drafts, not the published texts); IEC 60332-3-24:2000+A1:2008; EN 13501-3 draft A2.

Work with AYKYZ

Who makes or stocks this cable?

Makers and stockists of this cable family appear here as sponsors for your region, each marked "Sponsored"; a listing never changes what this page says about the cable.

Related cables

More CSN (Czech Republic, Slovakia) designations

AYKYZ