CYKYLO

CYKYLO is a CSN (Czech Republic, Slovakia) cable designation: C = Copper conductor; Y = PVC insulation, normal type; K = kabel: a cable proper, for fixed installation; Y = PVC sheath; Lo = Bridge (flat) version (CVUT: M = bridged wire; VSB: "Lo = mustkove provedeni, plochy kabel"); CYKYLO = CYKYLo: flat (bridge) copper installation cable for plaster and conduits, PVC insulation and PVC sheath, 2 to 3 cores, no bedding, 450/750 V. 450/750 V. PN-KV-062-00 (NKT CYKYLo).

1 coding system recognises this code

Standard, worked reading and related types

Worked reading of CYKYLO:

  • CYKYLO: C = Copper conductor; Y = PVC insulation, normal type; K = kabel: a cable proper, for fixed installation; Y = PVC sheath; Lo = Bridge (flat) version (CVUT: M = bridged wire; VSB: "Lo = mustkove provedeni, plochy kabel"); CYKYLO = CYKYLo: flat (bridge) copper installation cable for plaster and conduits, PVC insulation and PVC sheath, 2 to 3 cores, no bedding, 450/750 V. 450/750 V. PN-KV-062-00 (NKT CYKYLo)

Related cable types: CYKY · CYKYZ · CYKYDY

CSN (Czech Republic, Slovakia)

SymbolMeaning
CCopper conductor
YPVC insulation, normal type
Kkabel: a cable proper, for fixed installation
YPVC sheath
LoBridge (flat) version (CVUT: M = bridged wire; VSB: "Lo = mustkove provedeni, plochy kabel")
CYKYLOCYKYLo: flat (bridge) copper installation cable for plaster and conduits, PVC insulation and PVC sheath, 2 to 3 cores, no bedding, 450/750 V. 450/750 V. PN-KV-062-00 (NKT CYKYLo)

What is CYKYLO cable?

CYKYLO: CYKYLo: flat (bridge) copper installation cable for plaster and conduits, PVC insulation and PVC sheath, 2 to 3 cores, no bedding, 450/750 V. Rating: 450/750 V. Standard: PN-KV-062-00 (NKT CYKYLo).

The NKT catalogue writes CYKYLo, shops print CYKYLO; the upper-cased input cannot tell them apart. Counts: 4J1,5, 4Bx1,5 and 4-J all mean 4 cores including a green-yellow one; the B / C / D letters after a count are colour-scheme codes of the old CSN 33 0165 table, not a "without protective core" flag. 3x150+70 is three 150 mm2 cores plus one smaller 70 mm2 core (PE or PEN).

Documents and pages the readings were taken from

CSN (Czech Republic, Slovakia): how to read the cable type names

Fire behaviour (EU CPR)

A CPR class is declared by the maker in its Declaration of Performance and printed on the sheath (EN 50575 cl 7). This decoder does not assign one. What the CPR classes mean →

Sources: EN 13501-6 draft and FprEN 50575:2014 final draft (drafts, not the published texts); IEC 60332-3-24:2000+A1:2008; EN 13501-3 draft A2.

Laying, sizes and datasheet: CYKYLO

Terms on this page: bedding · conduit