KS / KEPCO type names (Korea)
Korea · 26 types · KS / KEPCO type names (Korea) : comment lire les noms de types de câbles
TFR-CV | TFR-CV: XLPE insulated tray cable with a flame-retardant PVC sheath, 0.6/1 kV (also 6/10 kV) (0.6/1 kV; 6/10 kV (Taihan p.16, p.21)) |
HFCO | HFCO: XLPE insulated cable with a halogen-free, low-toxic flame-retardant polyolefin sheath, 0.6/1 kV (also 6/10 kV) (0.6/1 kV; 6/10 kV (Taihan p.18, p.23)) |
CNCV-W | CNCV-W: 22.9 kV-y concentric neutral cable, XLPE insulated, PVC sheathed, water-blocking (22.9 kV-y, multi-grounded distribution (Taihan p.24)) |
TR CNCV-W | TR CNCV-W: CNCV-W with tree-retardant XLPE insulation (22.9 kV-y (Taihan p.25)) |
FR CNCO-W | FR CNCO-W: 22.9 kV-y concentric neutral cable, halogen-free flame-retardant polyolefin sheath, water-blocking (22.9 kV-y, inside buildings (Taihan p.25)) |
CCE | CCE: 0.6/1 kV control cable, XLPE insulated, polyethylene sheathed (0.6/1 kV (Taihan p.30)) |
TFR-CVV | TFR-CVV: 0.6/1 kV PVC insulated control cable with a tray flame-retardant PVC sheath (0.6/1 kV (Taihan p.31)) |
HFCCO | HFCCO: 0.6/1 kV XLPE insulated control cable with a halogen-free flame-retardant polyolefin sheath (0.6/1 kV (Taihan p.32)) |
CVVS | CVVS: 0.6/1 kV PVC insulated control cable with a copper tape shield and a PVC sheath (0.6/1 kV (Taihan p.33)) |
CCVS | CCVS: 0.6/1 kV XLPE insulated control cable with a copper tape shield and a PVC sheath (0.6/1 kV (Taihan p.33)) |
CCES | CCES: 0.6/1 kV XLPE insulated control cable with a copper tape shield and a polyethylene sheath (0.6/1 kV (Taihan p.33)) |
TFR-CVVS | TFR-CVVS: CVVS with a tray flame-retardant PVC sheath (0.6/1 kV (Taihan p.36)) |
HFCCOS | HFCCOS: HFCCO with a copper tape shield (0.6/1 kV (Taihan p.37)) |
CVVSB | CVVSB: 0.6/1 kV PVC insulated control cable with a copper wire braid shield and a PVC sheath (0.6/1 kV (Taihan p.38)) |
TFR-CVVSB | TFR-CVVSB: CVVSB with a tray flame-retardant PVC sheath (0.6/1 kV (Taihan p.40)) |
HFCCOSB | HFCCOSB: HFCCO with a copper wire braid shield (0.6/1 kV (Taihan p.41)) |
CVV-AMS | CVV-AMS: 0.6/1 kV PVC insulated signal cable in pairs, aluminium-mylar tape shield over all pairs, PVC sheath (0.6/1 kV (Taihan p.42)) |
CVV-I/CAMS | CVV-I/CAMS: CVV-AMS with an aluminium-mylar tape shield on each pair as well (0.6/1 kV (Taihan p.42)) |
TFR-CVV-AMS | TFR-CVV-AMS: CVV-AMS with a high flame-retardant PVC sheath (0.6/1 kV (Taihan p.42)) |
TFR-CVV-I/CAMS | TFR-CVV-I/CAMS: CVV-I/CAMS with a high flame-retardant PVC sheath (0.6/1 kV (Taihan p.42)) |
HFIO | HFIO: 0.6/1 kV halogen-free polyolefin insulated building wire, one copper conductor (0.6/1 kV (Taihan p.11)) |
TFR-GV | TFR-GV: 0.6/1 kV high flame-retardant PVC insulated earthing wire (0.6/1 kV (Taihan p.12)) |
TFR-8 | TFR-8: 0.6/1 kV fire-resistant cable for fire-service circuits, flame-retardant PVC sheath (0.6/1 kV (Taihan p.50)) |
HF-NFR-8 | HF-NFR-8: TFR-8 with a low-toxic flame-retardant polyolefin sheath (0.6/1 kV (Taihan p.50)) |
TFR-3 | TFR-3: 0.6/1 kV fire-retardant cable for emergency circuits, flame-retardant PVC sheath (0.6/1 kV (Taihan p.52)) |
HF-NFR-3 | HF-NFR-3: TFR-3 with a low-toxic flame-retardant polyolefin sheath (0.6/1 kV (Taihan p.52)) |