KS / KEPCO type names (Korea)

Korea · 26 typer · KS / KEPCO type names (Korea): så läser du kabeltypnamnen

TFR-CVTFR-CV: XLPE insulated tray cable with a flame-retardant PVC sheath, 0.6/1 kV (also 6/10 kV) (0.6/1 kV; 6/10 kV (Taihan p.16, p.21))
HFCOHFCO: XLPE insulated cable with a halogen-free, low-toxic flame-retardant polyolefin sheath, 0.6/1 kV (also 6/10 kV) (0.6/1 kV; 6/10 kV (Taihan p.18, p.23))
CNCV-WCNCV-W: 22.9 kV-y concentric neutral cable, XLPE insulated, PVC sheathed, water-blocking (22.9 kV-y, multi-grounded distribution (Taihan p.24))
TR CNCV-WTR CNCV-W: CNCV-W with tree-retardant XLPE insulation (22.9 kV-y (Taihan p.25))
FR CNCO-WFR CNCO-W: 22.9 kV-y concentric neutral cable, halogen-free flame-retardant polyolefin sheath, water-blocking (22.9 kV-y, inside buildings (Taihan p.25))
CCECCE: 0.6/1 kV control cable, XLPE insulated, polyethylene sheathed (0.6/1 kV (Taihan p.30))
TFR-CVVTFR-CVV: 0.6/1 kV PVC insulated control cable with a tray flame-retardant PVC sheath (0.6/1 kV (Taihan p.31))
HFCCOHFCCO: 0.6/1 kV XLPE insulated control cable with a halogen-free flame-retardant polyolefin sheath (0.6/1 kV (Taihan p.32))
CVVSCVVS: 0.6/1 kV PVC insulated control cable with a copper tape shield and a PVC sheath (0.6/1 kV (Taihan p.33))
CCVSCCVS: 0.6/1 kV XLPE insulated control cable with a copper tape shield and a PVC sheath (0.6/1 kV (Taihan p.33))
CCESCCES: 0.6/1 kV XLPE insulated control cable with a copper tape shield and a polyethylene sheath (0.6/1 kV (Taihan p.33))
TFR-CVVSTFR-CVVS: CVVS with a tray flame-retardant PVC sheath (0.6/1 kV (Taihan p.36))
HFCCOSHFCCOS: HFCCO with a copper tape shield (0.6/1 kV (Taihan p.37))
CVVSBCVVSB: 0.6/1 kV PVC insulated control cable with a copper wire braid shield and a PVC sheath (0.6/1 kV (Taihan p.38))
TFR-CVVSBTFR-CVVSB: CVVSB with a tray flame-retardant PVC sheath (0.6/1 kV (Taihan p.40))
HFCCOSBHFCCOSB: HFCCO with a copper wire braid shield (0.6/1 kV (Taihan p.41))
CVV-AMSCVV-AMS: 0.6/1 kV PVC insulated signal cable in pairs, aluminium-mylar tape shield over all pairs, PVC sheath (0.6/1 kV (Taihan p.42))
CVV-I/CAMSCVV-I/CAMS: CVV-AMS with an aluminium-mylar tape shield on each pair as well (0.6/1 kV (Taihan p.42))
TFR-CVV-AMSTFR-CVV-AMS: CVV-AMS with a high flame-retardant PVC sheath (0.6/1 kV (Taihan p.42))
TFR-CVV-I/CAMSTFR-CVV-I/CAMS: CVV-I/CAMS with a high flame-retardant PVC sheath (0.6/1 kV (Taihan p.42))
HFIOHFIO: 0.6/1 kV halogen-free polyolefin insulated building wire, one copper conductor (0.6/1 kV (Taihan p.11))
TFR-GVTFR-GV: 0.6/1 kV high flame-retardant PVC insulated earthing wire (0.6/1 kV (Taihan p.12))
TFR-8TFR-8: 0.6/1 kV fire-resistant cable for fire-service circuits, flame-retardant PVC sheath (0.6/1 kV (Taihan p.50))
HF-NFR-8HF-NFR-8: TFR-8 with a low-toxic flame-retardant polyolefin sheath (0.6/1 kV (Taihan p.50))
TFR-3TFR-3: 0.6/1 kV fire-retardant cable for emergency circuits, flame-retardant PVC sheath (0.6/1 kV (Taihan p.52))
HF-NFR-3HF-NFR-3: TFR-3 with a low-toxic flame-retardant polyolefin sheath (0.6/1 kV (Taihan p.52))