YY

YY is a DIN VDE 0271/0276 power cables (Germany) cable designation: Y = Polyvinyl Chloride (PVC); Y = Polyvinyl Chloride (PVC).

5 coding systems recognise this code

DIN VDE 0271/0276 power cables (Germany)

SymbolMeaning
YPolyvinyl Chloride (PVC)
YPolyvinyl Chloride (PVC)

How to read a DIN VDE 0271/0276 power cables (Germany) cable code

China (GB / JB/T / MT cable model codes)

SymbolMeaning
YPolyethylene (PE) Or Polyolefin
YPolyethylene (PE) Or Polyolefin

How to read a China (GB / JB/T / MT cable model codes) cable code

ZN-TF-500 (Poland, MV cables)

SymbolMeaning
YPolyvinyl Chloride (PVC) Sheath
YPolyvinyl Chloride (PVC) Sheath

How to read a ZN-TF-500 (Poland, MV cables) cable code

India (IS 1554 / IS 7098 cable code)

SymbolMeaning
YPolyvinyl Chloride (PVC)
YPolyvinyl Chloride (PVC)

How to read a India (IS 1554 / IS 7098 cable code) cable code

NEN 3207 / KEMA (Netherlands)

SymbolMeaning
YCross-Linked Polyethylene (XLPE)
YCross-Linked Polyethylene (XLPE)

How to read a NEN 3207 / KEMA (Netherlands) cable code

How to read a DIN VDE 0271/0276 power cables (Germany) cable code

A DIN VDE 0271/0276 power cables (Germany) designation (Germany) is a row of letter groups, and each group stands for one part of the cable: conductor, insulation, screen, armour, sheath, or the standard it follows. The decoder knows 51 symbols for this system.

What does Y mean in a DIN VDE 0271/0276 power cables (Germany) cable code? Y means Polyvinyl Chloride (PVC).

Fire behaviour (EU CPR)

A CPR class is declared by the maker in its Declaration of Performance and printed on the sheath (EN 50575 cl 7). This decoder does not assign one. What the CPR classes mean →

Sources: EN 13501-6 draft and FprEN 50575:2014 final draft (drafts, not the published texts); IEC 60332-3-24:2000+A1:2008; EN 13501-3 draft A2.

YY as the cable designer builds it, 3x95 0.6/1 kV

Overall diameter 35.9 mm, about 3,350 kg/km. Nominal values from the standard's tables for this size, computed, not a maker's data.

LayerMaterialThickness, mmOver the layer, mm
InsulationXLPE1.113.7
FillerPP29.5
Inner covering / beddingPVC1.231.9
SheathPVC2.035.9

YY on a drum

The smallest drum that passes every check, for 35.9 mm and about 3,350 kg/km as the cable designer builds it. Drums as their makers print them; lengths are estimates: whole layers wound nested (each turn in the groove of the layer below), wound diameter 1.05 × OD, 50 mm freeboard under the flange rim. Cable makers' own tables print less, as they count aligned layers.

LengthDrum size (its makers)LayersGross weight
500 mKTG 16 (1600 mm flange), wood KTG drums (Europe), Bayka, KTG7 of 101,951–1,984 kg
1,000 mKTG 20 (2000 mm flange), wood KTG drums (Europe), Bayka, KTG8 of 93,829–3,950 kg

Barrel at least 15 × OD = 539 mm for a cable of this kind (Low voltage, multi-core): KTG table, the cable's datasheet wins. A load rating is the drum maker's own.

Other lengths, drums and weights: the cable drum calculator

Load it on a truck: 1000 m on its drum in the loading planner

Laying, sizes and datasheet: YY

Current rating and voltage drop: One circuit, C: cable on a wall, 30 °C air: about 278 A. At that current over 100 m, three-phase 400 V, cos φ 0.9: a voltage drop of about 3.1 %. Sources: IEC 60364-5-52:2009, Table B.52.5, p. 44; IEC 60228:2023 Table 4, p. 13; IEC 60228:2023 Annex B, p. 18; IEC 60364-5-52:2009 (ed. 3.0) Annex G (informative), pp. 74 to 75 (read in the standard text) Cable size calculator: smallest section for a load, every factor shown · Voltage drop calculator: IEC 60364-5-52 method and limits

YY belongs to the family LV XLPE power cables: the lowest laying temperature, bending radius, pulling, depth, drum handling and the test after laying, every rule with its sources. Laying and handling guide: LV XLPE power cables