NYKYBY

NYKYBY is a DIN VDE 0271/0276 power cables (Germany) cable designation: N = VDE Standard; Y = Polyvinyl Chloride (PVC); K = Lead Sheath; Y = Polyvinyl Chloride (PVC); B = Steel Tape Armour; Y = Polyvinyl Chloride (PVC).

3 coding systems recognise this code

Standard, worked reading and related types

Worked reading of NYKYBY:

  • NYKYBY: N = VDE Standard; Y = Polyvinyl Chloride (PVC); K = Lead Sheath; Y = Polyvinyl Chloride (PVC); B = Steel Tape Armour; Y = Polyvinyl Chloride (PVC)

Related cable types: NYCYBY · nykyry · NYBY · NYFLBY · NYYHY · NYKY-J

DIN VDE 0271/0276 power cables (Germany)

SymbolMeaning
NVDE Standard
YPolyvinyl Chloride (PVC)
KLead Sheath
YPolyvinyl Chloride (PVC)
BSteel Tape Armour
YPolyvinyl Chloride (PVC)

How to read a DIN VDE 0271/0276 power cables (Germany) cable code

TS 621 / TSE (Turkey)

SymbolMeaning
NCable Resistant To Light & Normal Mechanical Load For Fixed Installation
YFlat Conductor
KCorrosion Resistant
YFlat Conductor
BFine-Wired For Fixed Installations-Class 5
YFlat Conductor

How to read a TS 621 / TSE (Turkey) cable code

DIN VDE 0250 cords, control and special cables (Germany)

SymbolMeaning
NVDE Standard
YPolyvinyl Chloride (PVC); Control-Cable Key: Thermoplastics In General
KCold Resistant
YPolyvinyl Chloride (PVC); Control-Cable Key: Thermoplastics In General
BLead Sheath
YPolyvinyl Chloride (PVC); Control-Cable Key: Thermoplastics In General

How to read a DIN VDE 0250 cords, control and special cables (Germany) cable code

How to read a DIN VDE 0271/0276 power cables (Germany) cable code

A DIN VDE 0271/0276 power cables (Germany) designation (Germany) is a row of letter groups, and each group stands for one part of the cable: conductor, insulation, screen, armour, sheath, or the standard it follows. The decoder knows 51 symbols for this system.

What does N mean in a DIN VDE 0271/0276 power cables (Germany) cable code? N means VDE Standard.

What does Y mean in a DIN VDE 0271/0276 power cables (Germany) cable code? Y means Polyvinyl Chloride (PVC).

What does K mean in a DIN VDE 0271/0276 power cables (Germany) cable code? K means Lead Sheath.

What does B mean in a DIN VDE 0271/0276 power cables (Germany) cable code? B means Steel Tape Armour.

Fire behaviour (EU CPR)

A CPR class is declared by the maker in its Declaration of Performance and printed on the sheath (EN 50575 cl 7). This decoder does not assign one. What the CPR classes mean →

Sources: EN 13501-6 draft and FprEN 50575:2014 final draft (drafts, not the published texts); IEC 60332-3-24:2000+A1:2008; EN 13501-3 draft A2.

Laying, sizes and datasheet: NYKYBY

Terms on this page: steel tape armour

Work with NYKYBY

Who makes or stocks this cable?

Makers and stockists of this cable family appear here as sponsors for your region, each marked "Sponsored"; a listing never changes what this page says about the cable.

Related cables

More DIN VDE 0271/0276 power cables (Germany) designations

NYKYBY