NAYFY-O

NAYFY-O is a DIN VDE 0271/0276 power cables (Germany) cable designation: N = VDE Standard; A = Aluminium Conductor; Y = Polyvinyl Chloride (PVC); F = Flat Galvanized Steel Wire; Y = Polyvinyl Chloride (PVC); -O = Without Earthing Core (No Green/Yellow Core).

2 coding systems recognise this code

Standard, worked reading and related types

Standards behind these values: IEC 60502-1:2004 (edition 2.0): Power cables with extruded insulation and their accessories for rated voltages from 1 kV (Um = 1,2 kV) up to 30 kV (Um = 36 kV) - Part 1: Cables for rated voltages of 1 kV (Um = 1,2 kV) and 3 kV (Um = 3,6 kV); IEC 60228:2023 (edition 4.0): Conductors of insulated cables. How the values are sourced

Worked reading of NAYFY-O 4x16 0.6/1 kV:

  • NAYFY-O: N = VDE Standard; A = Aluminium Conductor; Y = Polyvinyl Chloride (PVC); F = Flat Galvanized Steel Wire; Y = Polyvinyl Chloride (PVC); -O = Without Earthing Core (No Green/Yellow Core)
  • 4x16 0.6/1 kV: 4 cores, each aluminium 16 mm²; rated voltage 0.6/1 kV

Related cable types: NAYBYO · nayy-o · NAYY · NYY-O · NA2XY-O · NAY2Y

DIN VDE 0271/0276 power cables (Germany)

SymbolMeaning
NVDE Standard
AAluminium Conductor
YPolyvinyl Chloride (PVC)
FFlat Galvanized Steel Wire
YPolyvinyl Chloride (PVC)
-OWithout Earthing Core (No Green/Yellow Core)

How to read a DIN VDE 0271/0276 power cables (Germany) cable code

DIN VDE 0250 cords, control and special cables (Germany)

SymbolMeaning
NVDE Standard
ASingle-Core Non-Sheathed Cable
YPolyvinyl Chloride (PVC); Control-Cable Key: Thermoplastics In General
FFlexible (Fine-Stranded Conductor, As In SiHF, SiF) Or Flexible Luminaire Wire
YPolyvinyl Chloride (PVC); Control-Cable Key: Thermoplastics In General
-OWithout Earthing Core (No Green/Yellow Core)

How to read a DIN VDE 0250 cords, control and special cables (Germany) cable code

How to read a DIN VDE 0271/0276 power cables (Germany) cable code

A DIN VDE 0271/0276 power cables (Germany) designation (Germany) is a row of letter groups, and each group stands for one part of the cable: conductor, insulation, screen, armour, sheath, or the standard it follows. The decoder knows 51 symbols for this system.

What does N mean in a DIN VDE 0271/0276 power cables (Germany) cable code? N means VDE Standard.

What does A mean in a DIN VDE 0271/0276 power cables (Germany) cable code? A means Aluminium Conductor.

What does Y mean in a DIN VDE 0271/0276 power cables (Germany) cable code? Y means Polyvinyl Chloride (PVC).

What does F mean in a DIN VDE 0271/0276 power cables (Germany) cable code? F means Flat Galvanized Steel Wire.

What does -O mean in a DIN VDE 0271/0276 power cables (Germany) cable code? -O means Without Earthing Core (No Green/Yellow Core).

Fire behaviour (EU CPR)

A CPR class is declared by the maker in its Declaration of Performance and printed on the sheath (EN 50575 cl 7). This decoder does not assign one. What the CPR classes mean →

Sources: EN 13501-6 draft and FprEN 50575:2014 final draft (drafts, not the published texts); IEC 60332-3-24:2000+A1:2008; EN 13501-3 draft A2.

NAYFY-O: equivalents in other countries

Shown for 4x16 0.6/1 kV. Each country's rules are applied to this build, keeping the conductor, section, cores, voltage, screen, armour and sheath.

CountryStandardName in that countryVerdictDifferences
GermanyHD 603 3-G (DIN VDE 0276-603)NAYFY 4x16 RM 0,6/1 kVEquivalentevery value the same
IndiaIS 1554 (Part 1)AYFY 4x16 1100 VCloserated 0.635/1.1 kV (same Um 1.2 kV); routine voltage test 3 kV a.c., 5 min (this cable 3.5 kV; IS 1554 (Part 1) cl. 16.2, IS 7098 (Part 1) cl. 17.2.1, IEC 60502-1 Table 11); Inner covering / bedding 1 → 0.3 mm; Sheath 1.8 → 1.4 mm

Nominal values computed by each standard's rules, not manufacturer data. This is not a statement that two cables are interchangeable: the buyer's specification and the maker's type test decide.

NAYFY-O as the cable designer builds it, 4x16 0.6/1 kV

Overall diameter 23.9 mm, about 940 kg/km. Nominal values from the standard's tables for this size, computed, not a maker's data.

LayerMaterialThickness, mmOver the layer, mm
InsulationPVC1.06.9
FillerPP16.7
Inner covering / beddingPVC1.018.7
Wire armourSteel14 × 0.8020.3
SheathPVC1.823.9

NAYFY-O on a drum

The smallest drum that passes every check, for 23.9 mm and about 940 kg/km as the cable designer builds it. Drums as their makers print them; lengths are estimates: whole layers wound nested (each turn in the groove of the layer below), wound diameter 1.05 × OD, 50 mm freeboard under the flange rim. Cable makers' own tables print less, as they count aligned layers.

LengthDrum size (its makers)LayersGross weight
500 mKTG 12 (1250 mm flange), wood KTG drums (Europe), Bayka, KTG8 of 11614–635 kg
1,000 mKTG 14 (1400 mm flange), wood KTG drums (Europe), Bayka, KTG13 of 131,115–1,139 kg

Barrel at least 15 × OD = 358 mm for a cable of this kind (Low voltage, multi-core): KTG table, the cable's datasheet wins. A load rating is the drum maker's own. A steel drum whose maker prints none is checked against the DIN 46391-4 guide load instead: 28 kN per m³ of gross winding volume.

Other lengths, drums and weights: the cable drum calculator

Load it on a truck: 1000 m on its drum in the loading planner

Laying, sizes and datasheet: NAYFY-O

Current rating and voltage drop: One circuit, C: cable on a wall, 30 °C air: about 59 A. At that current over 100 m, three-phase 400 V, cos φ 0.9: a voltage drop of about 5.4 %. Sources: IEC 60364-5-52:2009, Table B.52.4, p. 43; IEC 60228:2023 Table 4, p. 13; IEC 60228:2023 Annex B, p. 18; IEC 60364-5-52:2009 (ed. 3.0) Annex G (informative), pp. 74 to 75 (read in the standard text) Cable size calculator: smallest section for a load, every factor shown · Voltage drop calculator: IEC 60364-5-52 method and limits

NAYFY-O belongs to the family LV armoured cables: the lowest laying temperature, bending radius, pulling, depth, drum handling and the test after laying, every rule with its sources. Laying and handling guide: LV armoured cables

Selling this cable? Open it in the designer and get a datasheet with your logo (Pro). Open the cable designer · See Pro

Work with NAYFY-O

Who makes or stocks this cable?

Makers and stockists of this cable family appear here as sponsors for your region, each marked "Sponsored"; a listing never changes what this page says about the cable.

Related cables

More DIN VDE 0271/0276 power cables (Germany) designations

NAYFY-O