LiYY

LiYY is a VDE telecom, signal and fibre cables (DIN VDE 0815, 0816, 0813, 0888) cable designation: Li = Stranded Conductor, Flexible (Litzenleiter To VDE 0812); Y = Polyvinyl Chloride (PVC); Y = Polyvinyl Chloride (PVC).

2 coding systems recognise this code

VDE telecom, signal and fibre cables (DIN VDE 0815, 0816, 0813, 0888)

SymbolMeaning
LiStranded Conductor, Flexible (Litzenleiter To VDE 0812)
YPolyvinyl Chloride (PVC)
YPolyvinyl Chloride (PVC)

How to read a VDE telecom, signal and fibre cables (DIN VDE 0815, 0816, 0813, 0888) cable code

DIN VDE 0250 cords, control and special cables (Germany)

SymbolMeaning
LiEquipment Wire With Fine Stranded Conductor
YPolyvinyl Chloride (PVC); Control-Cable Key: Thermoplastics In General
YPolyvinyl Chloride (PVC); Control-Cable Key: Thermoplastics In General

How to read a DIN VDE 0250 cords, control and special cables (Germany) cable code

Fire behaviour (EU CPR)

A CPR class is declared by the maker in its Declaration of Performance and printed on the sheath (EN 50575 cl 7). This decoder does not assign one. What the CPR classes mean →

Sources: EN 13501-6 draft and FprEN 50575:2014 final draft (drafts, not the published texts); IEC 60332-3-24:2000+A1:2008; EN 13501-3 draft A2.

LiYY as the cable designer builds it, 4x0.5 500 V

Overall diameter 5.8 mm, about 50 kg/km. Nominal values from the standard's tables for this size, computed, not a maker's data.

LayerMaterialThickness, mmOver the layer, mm
InsulationPVC0.451.8
Separation tapePolyester0.054.4
SheathPVC0.705.8

LiYY on a drum

The smallest drum that passes every check, for 5.8 mm and about 50 kg/km as the cable designer builds it. Drums as their makers print them; lengths are estimates within a few per cent of the cable makers' own tables: whole layers, wound diameter 1.05 × OD, 50 mm freeboard under the flange rim.

LengthDrum size (its makers)LayersGross weight
500 mKTG 3 (390 mm flange), plastic KTG drums (Europe), KTG12 of 1327 kg
1,000 mKTG 5 (500 mm flange), plastic KTG drums (Europe), Bayka, KTG19 of 2053–54 kg

Barrel at least 20 × OD = 117 mm for a cable of this kind (Telecom, data and control cable): KTG table, the cable's datasheet wins. A load rating is the drum maker's own.

Other lengths, drums and weights: the cable drum calculator

Load it on a truck: 1000 m on its drum in the loading planner

Laying, sizes and datasheet: LiYY

LiYY belongs to the family Control and instrument cables: the lowest laying temperature, bending radius, pulling, depth, drum handling and the test after laying, every rule with its sources. Laying and handling guide: Control and instrument cables