LS
LS is a Layer-list designation (CU/XLPE/SWA/PVC style, IEC and BS practice) cable designation: LS = Lead Sheath (Prysmian layer lists); Low Smoke (in compound names such as LS0H).
4 coding systems recognise this code
Standard, worked reading and related types
Worked reading of LS:
LS: LS = Lead Sheath (Prysmian layer lists); Low Smoke (in compound names such as LS0H)
Layer-list designation (CU/XLPE/SWA/PVC style, IEC and BS practice)
| Symbol | Meaning |
|---|---|
LS | Lead Sheath (Prysmian layer lists); Low Smoke (in compound names such as LS0H) |
How to read a Layer-list designation (CU/XLPE/SWA/PVC style, IEC and BS practice) cable code
DIN VDE 0250 cords, control and special cables (Germany)
| Symbol | Meaning |
|---|---|
L | Fluorescent-Tube Cable |
S | Braiding Of Galvanised Steel Wires |
How to read a DIN VDE 0250 cords, control and special cables (Germany) cable code
Norwegian type designation (NEK 606 offshore and Norwegian land cables)
| Symbol | Meaning |
|---|---|
L | Air + Plastics (Coaxial Cable) |
S | Silicone Rubber |
How to read a Norwegian type designation (NEK 606 offshore and Norwegian land cables) cable code
VG 95218 (German Navy cables)
| Symbol | Meaning |
|---|---|
L | Light (Weight-Reduced) Design |
S | Screen |
How to read a Layer-list designation (CU/XLPE/SWA/PVC style, IEC and BS practice) cable code
A Layer-list designation (CU/XLPE/SWA/PVC style, IEC and BS practice) designation (UK / International) is a row of letter groups, and each group stands for one part of the cable: conductor, insulation, screen, armour, sheath, or the standard it follows. The decoder knows 119 symbols for this system.
What does LS mean in a Layer-list designation (CU/XLPE/SWA/PVC style, IEC and BS practice) cable code? LS means Lead Sheath (Prysmian layer lists); Low Smoke (in compound names such as LS0H).
Fire behaviour (EU CPR)
Halogen-free compound (LS). Under the CPR this shows in the additional classes: acidity a1 to a3 (EN 60754-2) and smoke s1 to s3 (EN 50399; s1a and s1b add the 3 m cube test EN 61034-2). The main class, Aca to Fca, depends on the whole construction.
Typically targeted, as declared by makers for this kind of construction in the examples this site checked (not the class of this cable):
B2ca-s1a,d0,a11-CXKH-R-J, Kablo VrchlabíCca-s1b,d1,a1FG16(O)M16, Nexans (La Triveneta Cavi)B2ca-s1a,d1,a1FG18(O)M16, Nexans (La Triveneta Cavi)DcaFXQJ, Nexans NorwayCca-s1b,d1,a1H07Z1-K, Nexans SpainB2ca-s1,d2,a1AXQJ-RMF, Prysmian Sweden (12/20 kV)B2ca-s1a,d1,a1RZ1-K (AS), Top CableCca-s1b,d1,a1RZ1FZ1-K (AS), Top Cable
Listed as sources, alphabetically by maker. No maker pays to appear here.
A CPR class is declared by the maker in its Declaration of Performance and printed on the sheath (EN 50575 cl 7). This decoder does not assign one. What the CPR classes mean →
Sources: EN 13501-6 draft and FprEN 50575:2014 final draft (drafts, not the published texts); IEC 60332-3-24:2000+A1:2008; EN 13501-3 draft A2.
Work with LS
Who makes or stocks this cable?
Makers and stockists of this cable family appear here as sponsors for your region, each marked "Sponsored"; a listing never changes what this page says about the cable.
Related cables
More Layer-list designation (CU/XLPE/SWA/PVC style, IEC and BS practice) designations