60245 IEC 75

60245 IEC 75 is a IEC 60227 / IEC 60245 type numbers cable designation: 60245 IEC 75 = 60245 IEC 75: polychloroprene sheathed lift cable, 300/500 V; 60245 IEC 75 = 60245 IEC 75: polychloroprene or other equivalent synthetic elastomer sheathed lift cable, 300/500 V. 300/500 V; 6, 9, 12, 18, 24 or 30 cores of 0.75 or 1 mm2, class 5 (resistance +5 %); IE4 rubber insulation 0.8 mm; SE4 polychloroprene sheath 1.5 to 2.5 mm, flame retardant; 60 C (IEC 60245-5 cl. 2, Table 1). IEC 60245-5 (clause 2); code IEC 60245-1 Annex A.

1 coding system recognises this code

IEC 60227 / IEC 60245 type numbers

SymbolMeaning
60245 IEC 7560245 IEC 75: polychloroprene sheathed lift cable, 300/500 V
60245 IEC 7560245 IEC 75: polychloroprene or other equivalent synthetic elastomer sheathed lift cable, 300/500 V. 300/500 V; 6, 9, 12, 18, 24 or 30 cores of 0.75 or 1 mm2, class 5 (resistance +5 %); IE4 rubber insulation 0.8 mm; SE4 polychloroprene sheath 1.5 to 2.5 mm, flame retardant; 60 C (IEC 60245-5 cl. 2, Table 1). IEC 60245-5 (clause 2); code IEC 60245-1 Annex A

What is 60245 IEC 75 cable?

60245 IEC 75: polychloroprene or other equivalent synthetic elastomer sheathed lift cable, 300/500 V. Rating: 300/500 V; 6, 9, 12, 18, 24 or 30 cores of 0.75 or 1 mm2, class 5 (resistance +5 %); IE4 rubber insulation 0.8 mm; SE4 polychloroprene sheath 1.5 to 2.5 mm, flame retardant; 60 C (IEC 60245-5 cl. 2, Table 1). Standard: IEC 60245-5 (clause 2); code IEC 60245-1 Annex A.

IEC 60245-5 (standard): clause 2, braided, tough rubber or polychloroprene sheathed lift cable for normal use (2, p. 11): 70 braided, 74 tough rubber sheathed, 75 polychloroprene or other equivalent synthetic elastomer sheathed (2.1); 300/500 V (2.2); 6, 9, 12, 18, 24 or 30 conductors (other counts not precluded), class 5 with the maximum resistance raised 5 %, plain or tinned (2.3.1); rubber insulation IE 4 (2.3.3 as amended by Amendment 1, 2003; IE 1 in the 1994 text), an optional textile braid on each core (2.3.4); the cores twisted round a central heart of hemp, jute or the like, which may carry a strain-bearing member covered with non-conducting material, in one layer up to 12 cores and one or two above (2.3.5, 2.3.6, p. 13); cores identified as IEC 60245-1 4.1 or 4.2 (2.3.6); Table 1 (p. 15): 6, 9, 12, 18, 24, 30 x 0.75 (non-preferred) and x 1 mm2, insulation 0.8 mm (0.6 mm for 0.75 mm2 cores under a textile braid); the overall diameter is not specified (2.3.8); 60 C in normal use (2.5, p. 15). Outer covering (2.3.7.2, pp. 13 to 15): a cotton helical binding or a textile inner braid, then a sheath of compound SE4 (polychloroprene or equivalent), flame retardant; sheath 1.5 mm (6 cores), 2.0 mm (9, 12, 18 cores), 2.5 mm (24, 30 cores) (Table 1, column 3). Code designation (IEC 60245-1:2003+A1:2007 Annex A, p. 21 to 22): the first numeral is the basic class (0 non-sheathed for fixed wiring, 5 normal duty flexible, 6 heavy duty flexible, 7 special duty, 8 special application), the second the type within the class, so the number is read whole. The old spelling drops the 60 ('227 IEC 53' = '60227 IEC 53', IEC renumbering); Helukabel's table prints 227 / 245, EN-JV and Top Cable 60227. Core colours (IEC 60245-1:2003+A1:2007 4.1.2, p. 9): one and two cores no preferred scheme; three cores green-and-yellow, blue, brown or brown, black, grey; four cores green-and-yellow, brown, black, grey or blue, brown, black, grey; five cores green-and-yellow, blue, brown, black, grey or blue, brown, black, grey, black; above five cores by colour (green-and-yellow and blue in the outer layer) or by number (4.2). Drawn with the green-and-yellow set when the size says so (3G1.5), otherwise the set without it; two cores are drawn brown and blue (the HD 308 pair, as the standard prefers none); above five cores black numbered cores, the green-and-yellow core last. China: GB/T 5013.5-2008 is an identical adoption (IDT) of IEC 60245-5:1994 (SAMR record, checked 2026-11-09; the portal serves no text of it), so its values are this edition's.

Documents and pages the readings were taken from

  • IEC 60245-5 ed. 2.0 (1994): clause 2, pp. 11, 13 and 15, Table 1 p. 15
  • IEC 60245-5 Amendment 1 (2003-12): p. 3 (2.3.3: IE 4 in place of IE 1)
  • IEC 60245-1 ed. 4.1 (2003 + A1:2007): Annex A code designation p. 21 to 22; 4.1.2 preferred core colours p. 9, 4.2 cores by number pp. 9 to 10

IEC 60227 / IEC 60245 type numbers: how to read the cable type names

Fire behaviour (EU CPR)

  • Flame retardant (60245 IEC 75). The single-cable test behind class Eca is EN 60332-1-2 (the flame stops within 425 mm). Bunched cables are tested by IEC 60332-3-24 category C (1.5 l/m, 20 min, char at most 2.5 m), which is not a CPR class test; the CPR ladder test for B1ca to Dca is EN 50399.

A CPR class is declared by the maker in its Declaration of Performance and printed on the sheath (EN 50575 cl 7). This decoder does not assign one. What the CPR classes mean →

Sources: EN 13501-6 draft and FprEN 50575:2014 final draft (drafts, not the published texts); IEC 60332-3-24:2000+A1:2008; EN 13501-3 draft A2.