60227 IEC 75 is a IEC 60227 / IEC 60245 type numbers cable designation: 60227 IEC 75 = 60227 IEC 75: oil-resistant PVC sheathed flexible control cable, 2 to 60 cores (Chinese RVVY; no HAR twin in the sources read); 60227 IEC 75 = 60227 IEC 75: oil-resistant PVC sheathed flexible control cable, unscreened (Chinese RVVY). 300/500 V; 2 to 60 cores (preferred 2, 3, 4, 5, 6, 7, 12, 18, 27, 36, 48, 60), class 5, 0.5 to 2.5 mm2; PVC/D insulation, oil-resistant PVC/ST9 sheath, no screen; numbered cores; 70 C (IEC 60227-7 cl. 2, Table 2). IEC 60227-7 (clause 2).
1 coding system recognises this code
IEC 60227 / IEC 60245 type numbers
| Symbol | Meaning |
|---|---|
60227 IEC 75 | 60227 IEC 75: oil-resistant PVC sheathed flexible control cable, 2 to 60 cores (Chinese RVVY; no HAR twin in the sources read) |
60227 IEC 75 | 60227 IEC 75: oil-resistant PVC sheathed flexible control cable, unscreened (Chinese RVVY). 300/500 V; 2 to 60 cores (preferred 2, 3, 4, 5, 6, 7, 12, 18, 27, 36, 48, 60), class 5, 0.5 to 2.5 mm2; PVC/D insulation, oil-resistant PVC/ST9 sheath, no screen; numbered cores; 70 C (IEC 60227-7 cl. 2, Table 2). IEC 60227-7 (clause 2) |
What is 60227 IEC 75 cable?
60227 IEC 75: oil-resistant PVC sheathed flexible control cable, unscreened (Chinese RVVY). Rating: 300/500 V; 2 to 60 cores (preferred 2, 3, 4, 5, 6, 7, 12, 18, 27, 36, 48, 60), class 5, 0.5 to 2.5 mm2; PVC/D insulation, oil-resistant PVC/ST9 sheath, no screen; numbered cores; 70 C (IEC 60227-7 cl. 2, Table 2). Standard: IEC 60227-7 (clause 2).
IEC 60227-7 (standard): 75 is the unscreened cable (2.1), so EN-JV's word 'screened' for 75 is not the standard's; 300/500 V; 2 to 60 class 5 conductors; PVC/D insulation; one green-and-yellow core from three cores, the others numbered; PVC/ST9 sheath 0.08 dL + 0.4 mm, at most 2.4 mm, which may fill the interstices; Table 2: 0.5 to 2.5 mm2, mean overall diameter 5.2 to 6.6 mm (2 x 0.5) and up; indoors, ambient +5 to +40 C, 70 C conductor and 60 C sheath (2.5). Makers: EN-JV p.28 (manufacturer): 60227IEC75, RVVY, with the same description as 74 ('screened'); the Chinese model has no P (screen) letter, so it is drawn without a screen. Code designation (IEC 60227-1:2007 Annex A, p. 20): the first numeral is the basic class (0 non-sheathed for fixed wiring, 1 sheathed for fixed wiring, 4 non-sheathed light duty flexible, 5 sheathed normal duty flexible, 7 sheathed special duty flexible), the second the type within the class, so the number is read whole. The old spelling drops the 60 ('227 IEC 53' = '60227 IEC 53', IEC renumbering); Helukabel's table prints 227 / 245, EN-JV and Top Cable 60227. Core identification (IEC 60227-7 2.3.3, p. 7 and 2.3.7, p. 8): from three cores one core green-and-yellow, every other core numbered as IEC 60227-1 4.2. Drawn as black numbered cores with the green-and-yellow core last; a two-core cable is drawn with one too (the reader gives every count the same rule; the standard has none below three cores).
Documents and pages the readings were taken from
- IEC 60227-7 ed. 1.2 (1995 + A1:2003 + A2:2011, consolidated redline): clause 2 p. 6 to 9, Table 2 p. 11
- IEC 60227-1 ed. 3.0 (2007): Annex A code designation p. 20; 5.2.1 insulation compounds PVC/C, PVC/D, PVC/E p. 11; 5.5 sheath compounds PVC/ST4, ST5, ST9, ST10 p. 14; 4.1.1, 4.1.2 preferred core colours and 4.2 cores by number p. 9
- EN-JV cable catalogue, model table of PVC insulated cables up to 450/750 V, pdf p.28
IEC 60227 / IEC 60245 type numbers: how to read the cable type names
Fire behaviour (EU CPR)
PVC sheath (60227 IEC 75).
Typically targeted, as declared by makers for this kind of construction in the examples this site checked (not the class of this cable):
EcaN1XV-R, Ahlsell (seller)Cca-s3,d1,a3FG16OR16, Nexans (La Triveneta Cavi)EcaU1000 R2V, Nexans (La Triveneta Cavi)EcaN2XSY, Waskönig+Walter (10 kV datasheet)
Listed as sources, alphabetically by maker. No maker pays to appear here.
A CPR class is declared by the maker in its Declaration of Performance and printed on the sheath (EN 50575 cl 7). This decoder does not assign one. What the CPR classes mean →
Sources: EN 13501-6 draft and FprEN 50575:2014 final draft (drafts, not the published texts); IEC 60332-3-24:2000+A1:2008; EN 13501-3 draft A2.