60227 IEC 01 is a IEC 60227 / IEC 60245 type numbers cable designation: 60227 IEC 01 = 60227 IEC 01: single-core non-sheathed PVC cable for general purposes, rigid conductor, 450/750 V (HAR twin H07V-U / H07V-R; Chinese BV); 60227 IEC 01 = 60227 IEC 01: single-core non-sheathed cable for general purposes, rigid (solid or stranded) copper conductor, 450/750 V. 450/750 V; 1 core, 1.5 to 400 mm2, class 1 (solid, 1.5 to 10 mm2) or class 2; PVC/C insulation; 70 C (IEC 60227-3 cl. 2, Table 1). IEC 60227-3 (clause 2); HD 21.3 (HAR H07V-U, H07V-R).
1 coding system recognises this code
IEC 60227 / IEC 60245 type numbers
| Symbol | Meaning |
|---|---|
60227 IEC 01 | 60227 IEC 01: single-core non-sheathed PVC cable for general purposes, rigid conductor, 450/750 V (HAR twin H07V-U / H07V-R; Chinese BV) |
60227 IEC 01 | 60227 IEC 01: single-core non-sheathed cable for general purposes, rigid (solid or stranded) copper conductor, 450/750 V. 450/750 V; 1 core, 1.5 to 400 mm2, class 1 (solid, 1.5 to 10 mm2) or class 2; PVC/C insulation; 70 C (IEC 60227-3 cl. 2, Table 1). IEC 60227-3 (clause 2); HD 21.3 (HAR H07V-U, H07V-R) |
What is 60227 IEC 01 cable?
60227 IEC 01: single-core non-sheathed cable for general purposes, rigid (solid or stranded) copper conductor, 450/750 V. Rating: 450/750 V; 1 core, 1.5 to 400 mm2, class 1 (solid, 1.5 to 10 mm2) or class 2; PVC/C insulation; 70 C (IEC 60227-3 cl. 2, Table 1). Standard: IEC 60227-3 (clause 2); HD 21.3 (HAR H07V-U, H07V-R).
IEC 60227-3 (standard): 450/750 V; one conductor, class 1 (solid) or class 2 (stranded); PVC/C insulation; Table 1: insulation 0.7 mm at 1.5 mm2 up to 2.6 mm at 400 mm2, mean overall diameter limits (1.5 mm2 class 1 2.6 to 3.2 mm, 400 mm2 27.5 to 33.2 mm), insulation resistance at 70 C; class 1 only to 10 mm2; 70 C in normal use (2.5). Makers: EN-JV p.28 (manufacturer): 60227IEC01, original model BV, 'Single core hard conductor non-sheathed cable for general purpose', 1 core 1.5-400 mm2, 70 C. Top Cable: H07V-U (60227 IEC 01), H07V-R (60227 IEC 01). Helukabel p.12: H 07V-U, H 07V-R, 450/750 V, HD 21.3 S3, 227 IEC 01; it also prints 227 IEC 01 against H 05V-U, which Top Cable gives as 60227 IEC 05. Code designation (IEC 60227-1:2007 Annex A, p. 20): the first numeral is the basic class (0 non-sheathed for fixed wiring, 1 sheathed for fixed wiring, 4 non-sheathed light duty flexible, 5 sheathed normal duty flexible, 7 sheathed special duty flexible), the second the type within the class, so the number is read whole. The old spelling drops the 60 ('227 IEC 53' = '60227 IEC 53', IEC renumbering); Helukabel's table prints 227 / 245, EN-JV and Top Cable 60227.
Documents and pages the readings were taken from
- IEC 60227-3 ed. 2.1 (1993 + A1:1997, consolidated redline): clause 2 p. 9, Table 1 p. 11
- IEC 60227-1 ed. 3.0 (2007): Annex A code designation p. 20; 5.2.1 insulation compounds PVC/C, PVC/D, PVC/E p. 11; 5.5 sheath compounds PVC/ST4, ST5, ST9, ST10 p. 14
- EN-JV cable catalogue, model table of PVC insulated cables up to 450/750 V, pdf p.28
- Top Cable 'RZ1-K, SZ1-K Low Voltage Range of Cables', wire and cord pages: 'H07V-U (60227 IEC 01)', 'H05V-U (60227 IEC 05)', 'H07V-K (60227 IEC 02)', 'H05V-K (60227 IEC 06)', '(60227 IEC 53)'
- Helukabel 'Technical Information', table 'Comparison of harmonized cables with IEC, DIN VDE and HD', pdf p.12
IEC 60227 / IEC 60245 type numbers: how to read the cable type names
Fire behaviour (EU CPR)
PVC sheath (60227 IEC 01).
Typically targeted, as declared by makers for this kind of construction in the examples this site checked (not the class of this cable):
EcaN1XV-R, Ahlsell (seller)Cca-s3,d1,a3FG16OR16, Nexans (La Triveneta Cavi)EcaU1000 R2V, Nexans (La Triveneta Cavi)EcaN2XSY, Waskönig+Walter (10 kV datasheet)
Listed as sources, alphabetically by maker. No maker pays to appear here.
A CPR class is declared by the maker in its Declaration of Performance and printed on the sheath (EN 50575 cl 7). This decoder does not assign one. What the CPR classes mean →
Sources: EN 13501-6 draft and FprEN 50575:2014 final draft (drafts, not the published texts); IEC 60332-3-24:2000+A1:2008; EN 13501-3 draft A2.
Work with 60227 IEC 01
Who makes or stocks this cable?
Makers and stockists of this cable family appear here as sponsors for your region, each marked "Sponsored"; a listing never changes what this page says about the cable.