60227 IEC 41

60227 IEC 41 is a IEC 60227 / IEC 60245 type numbers cable designation: 60227 IEC 41 = 60227 IEC 41: flat tinsel cord, two PVC insulated cores side by side, 300/300 V (HAR twin H03VH-Y); 60227 IEC 41 = 60227 IEC 41: flat tinsel cord, light PVC twin, 300/300 V. 300/300 V; 2 tinsel conductors laid parallel, flat, 2.2 x 4.4 to 3.5 x 7.0 mm, at most 270 ohm/km at 20 C; PVC/D insulation 0.8 mm; 70 C (IEC 60227-5 cl. 2, Table 1). IEC 60227-5 (clause 2); HD 21.5 (HAR H03VH-Y).

1 coding system recognises this code

IEC 60227 / IEC 60245 type numbers

SymbolMeaning
60227 IEC 4160227 IEC 41: flat tinsel cord, two PVC insulated cores side by side, 300/300 V (HAR twin H03VH-Y)
60227 IEC 4160227 IEC 41: flat tinsel cord, light PVC twin, 300/300 V. 300/300 V; 2 tinsel conductors laid parallel, flat, 2.2 x 4.4 to 3.5 x 7.0 mm, at most 270 ohm/km at 20 C; PVC/D insulation 0.8 mm; 70 C (IEC 60227-5 cl. 2, Table 1). IEC 60227-5 (clause 2); HD 21.5 (HAR H03VH-Y)

What is 60227 IEC 41 cable?

60227 IEC 41: flat tinsel cord, light PVC twin, 300/300 V. Rating: 300/300 V; 2 tinsel conductors laid parallel, flat, 2.2 x 4.4 to 3.5 x 7.0 mm, at most 270 ohm/km at 20 C; PVC/D insulation 0.8 mm; 70 C (IEC 60227-5 cl. 2, Table 1). Standard: IEC 60227-5 (clause 2); HD 21.5 (HAR H03VH-Y).

IEC 60227-5 (standard): 300/300 V; two conductors, each of strands of flattened copper or copper-alloy wires wound on a cotton, polyamide or similar thread; laid parallel in PVC/D insulation 0.8 mm with a groove on both sides between them; mean overall dimensions 2.2 x 4.4 to 3.5 x 7.0 mm; insulation resistance at 70 C 0.019 Mohm km; conductor resistance at most 270 ohm/km at 20 C (no cross-section given); 70 C in normal use (2.5). Makers: Helukabel p.12 (manufacturer): Light PVC-Twin cables, DIN VDE 0281 part 5, H 03VH-Y (old NLYZ), 0,1 mm2, 300/300 V, HD 21.5 S3, comparative design 227 IEC 41. Drawn round (no flat drawing). Code designation (IEC 60227-1:2007 Annex A, p. 20): the first numeral is the basic class (0 non-sheathed for fixed wiring, 1 sheathed for fixed wiring, 4 non-sheathed light duty flexible, 5 sheathed normal duty flexible, 7 sheathed special duty flexible), the second the type within the class, so the number is read whole. The old spelling drops the 60 ('227 IEC 53' = '60227 IEC 53', IEC renumbering); Helukabel's table prints 227 / 245, EN-JV and Top Cable 60227.

Documents and pages the readings were taken from

  • IEC 60227-5 ed. 3.0 (2011): clause 2 p. 7 to 8, Table 1 p. 8
  • IEC 60227-1 ed. 3.0 (2007): Annex A code designation p. 20; 5.2.1 insulation compounds PVC/C, PVC/D, PVC/E p. 11; 5.5 sheath compounds PVC/ST4, ST5, ST9, ST10 p. 14
  • Helukabel 'Technical Information', table 'Comparison of harmonized cables with IEC, DIN VDE and HD', pdf p.12

IEC 60227 / IEC 60245 type numbers: how to read the cable type names

Fire behaviour (EU CPR)

A CPR class is declared by the maker in its Declaration of Performance and printed on the sheath (EN 50575 cl 7). This decoder does not assign one. What the CPR classes mean →

Sources: EN 13501-6 draft and FprEN 50575:2014 final draft (drafts, not the published texts); IEC 60332-3-24:2000+A1:2008; EN 13501-3 draft A2.

Work with 60227 IEC 41

Who makes or stocks this cable?

Makers and stockists of this cable family appear here as sponsors for your region, each marked "Sponsored"; a listing never changes what this page says about the cable.

Related cables

More IEC 60227 / IEC 60245 type numbers designations

60227 IEC 41