60227 IEC 43

60227 IEC 43 is a IEC 60227 / IEC 60245 type numbers cable designation: 60227 IEC 43 = 60227 IEC 43: single-core PVC cord for indoor decorative lighting chains, two insulation layers, 300/300 V (Chinese SVR); 60227 IEC 43 = 60227 IEC 43: single-core cord for indoor decorative lighting chains, 300/300 V. 300/300 V; 1 core, class 6, 0.5 and 0.75 mm2; two PVC/D insulation layers, the outer of a contrasting colour (preferably green); 70 C (IEC 60227-5 cl. 4, Table 3). IEC 60227-5 (clause 4).

1 coding system recognises this code

IEC 60227 / IEC 60245 type numbers

SymbolMeaning
60227 IEC 4360227 IEC 43: single-core PVC cord for indoor decorative lighting chains, two insulation layers, 300/300 V (Chinese SVR)
60227 IEC 4360227 IEC 43: single-core cord for indoor decorative lighting chains, 300/300 V. 300/300 V; 1 core, class 6, 0.5 and 0.75 mm2; two PVC/D insulation layers, the outer of a contrasting colour (preferably green); 70 C (IEC 60227-5 cl. 4, Table 3). IEC 60227-5 (clause 4)

What is 60227 IEC 43 cable?

60227 IEC 43: single-core cord for indoor decorative lighting chains, 300/300 V. Rating: 300/300 V; 1 core, class 6, 0.5 and 0.75 mm2; two PVC/D insulation layers, the outer of a contrasting colour (preferably green); 70 C (IEC 60227-5 cl. 4, Table 3). Standard: IEC 60227-5 (clause 4).

IEC 60227-5 (standard): 300/300 V; one class 6 conductor; PVC/D insulation in two layers applied by dual extrusion, the outer adhering to the inner and of a contrasting colour, preferably green; Table 3: each layer at least 0.2 mm, overall at least 0.6 mm and 0.7 mm mean, mean overall diameter 2.3 to 2.7 mm (0.5 mm2) and 2.4 to 2.9 (0.75); a 240 h d.c. test at 220 V in salt water at 60 C (4.4.2); 70 C in normal use (4.5). This settles the makers' disagreement below: EN-JV's single-core decorative lighting cord is the standard's, Helukabel's row beside H 03VV-F is not (that light sheathed cord is 52). Drawn as one core with one insulation layer. Makers: The two library sources disagree. EN-JV p.28 (manufacturer): 60227IEC43, SVR, 'Flexible wire for indoor decorative lighting circuit', 1 core 0.5-0.75 mm2, and 60227IEC52 for the light PVC sheathed RVV. Helukabel p.12 prints 227 IEC 43 in the row of H 03VV-F / H 03VVH2-F (300/300 V, HD 21.5 S3). Drawn as EN-JV's single core. Code designation (IEC 60227-1:2007 Annex A, p. 20): the first numeral is the basic class (0 non-sheathed for fixed wiring, 1 sheathed for fixed wiring, 4 non-sheathed light duty flexible, 5 sheathed normal duty flexible, 7 sheathed special duty flexible), the second the type within the class, so the number is read whole. The old spelling drops the 60 ('227 IEC 53' = '60227 IEC 53', IEC renumbering); Helukabel's table prints 227 / 245, EN-JV and Top Cable 60227.

Documents and pages the readings were taken from

  • IEC 60227-5 ed. 3.0 (2011): clause 4 p. 9 to 10, Table 3 p. 10
  • IEC 60227-1 ed. 3.0 (2007): Annex A code designation p. 20; 5.2.1 insulation compounds PVC/C, PVC/D, PVC/E p. 11; 5.5 sheath compounds PVC/ST4, ST5, ST9, ST10 p. 14
  • EN-JV cable catalogue, model table of PVC insulated cables up to 450/750 V, pdf p.28
  • Helukabel 'Technical Information', table 'Comparison of harmonized cables with IEC, DIN VDE and HD', pdf p.12

IEC 60227 / IEC 60245 type numbers: how to read the cable type names

Fire behaviour (EU CPR)

A CPR class is declared by the maker in its Declaration of Performance and printed on the sheath (EN 50575 cl 7). This decoder does not assign one. What the CPR classes mean →

Sources: EN 13501-6 draft and FprEN 50575:2014 final draft (drafts, not the published texts); IEC 60332-3-24:2000+A1:2008; EN 13501-3 draft A2.