60245 IEC 03

60245 IEC 03 is a IEC 60227 / IEC 60245 type numbers cable designation: 60245 IEC 03 = 60245 IEC 03: heat-resistant silicone rubber insulated single-core cable, 300/500 V (HAR twin H05SJ-K); 60245 IEC 03 = 60245 IEC 03: heat-resistant silicone rubber insulated cable, 300/500 V. 300/500 V; 1 core, class 5 (plain, tinned or other metal coated, e.g. silver), 0.5 to 16 mm2; silicone rubber IE2 insulation, treated glass fibre braid; 180 C (IEC 60245-3 cl. 2, Table 1 as amended 1997). IEC 60245-3 (clause 2); HD 22.3 (HAR H05SJ-K).

1 coding system recognises this code

IEC 60227 / IEC 60245 type numbers

SymbolMeaning
60245 IEC 0360245 IEC 03: heat-resistant silicone rubber insulated single-core cable, 300/500 V (HAR twin H05SJ-K)
60245 IEC 0360245 IEC 03: heat-resistant silicone rubber insulated cable, 300/500 V. 300/500 V; 1 core, class 5 (plain, tinned or other metal coated, e.g. silver), 0.5 to 16 mm2; silicone rubber IE2 insulation, treated glass fibre braid; 180 C (IEC 60245-3 cl. 2, Table 1 as amended 1997). IEC 60245-3 (clause 2); HD 22.3 (HAR H05SJ-K)

What is 60245 IEC 03 cable?

60245 IEC 03: heat-resistant silicone rubber insulated cable, 300/500 V. Rating: 300/500 V; 1 core, class 5 (plain, tinned or other metal coated, e.g. silver), 0.5 to 16 mm2; silicone rubber IE2 insulation, treated glass fibre braid; 180 C (IEC 60245-3 cl. 2, Table 1 as amended 1997). Standard: IEC 60245-3 (clause 2); HD 22.3 (HAR H05SJ-K).

IEC 60245-3 with Amendment 1 (standard): 300/500 V; one class 5 conductor, wires plain, tinned or coated with another metal such as silver; optional separator; silicone rubber IE2 insulation extruded in one layer; a treated glass fibre braid over the core; Table 1 (as replaced by Amendment 1): 0.5 to 16 mm2, insulation 0.6 to 1.0 mm, mean overall diameter 2.6 to 3.3 mm (0.5 mm2) up to 7.3 to 9.1 mm (16 mm2); 180 C in normal use (2.5). Helukabel's H 05SJ-K range to 95 mm2 is the HD 22.3 type's, wider than the IEC table. Makers: Helukabel p.12 (manufacturer): Heat-resistant silicone-rubber cable, DIN VDE 0282 part 3, H 05SJ-K (old N2GAFU), 0,5 to 95 mm2, 300/500 V, HD 22.3 S2, 245 IEC 03. Code designation (IEC 60245-1:2003+A1:2007 Annex A, p. 21 to 22): the first numeral is the basic class (0 non-sheathed for fixed wiring, 5 normal duty flexible, 6 heavy duty flexible, 7 special duty, 8 special application), the second the type within the class, so the number is read whole. The old spelling drops the 60 ('227 IEC 53' = '60227 IEC 53', IEC renumbering); Helukabel's table prints 227 / 245, EN-JV and Top Cable 60227. China: GB/T 5013.3-2008 is an identical adoption (IDT) of IEC 60245-3:1994 (SAMR record, checked 2026-11-09; the portal serves no text of it), so its values are this edition's.

Documents and pages the readings were taken from

  • IEC 60245-3 ed. 2.0 (1994): clause 2 p. 9; Table 1 as replaced by Amendment 1 (1997) p. 3
  • IEC 60245-1 ed. 4.1 (2003 + A1:2007): Annex A code designation p. 21 to 22
  • Helukabel 'Technical Information', table 'Comparison of harmonized cables with IEC, DIN VDE and HD', pdf p.12

IEC 60227 / IEC 60245 type numbers: how to read the cable type names

Work with 60245 IEC 03

Who makes or stocks this cable?

Makers and stockists of this cable family appear here as sponsors for your region, each marked "Sponsored"; a listing never changes what this page says about the cable.

Related cables

More IEC 60227 / IEC 60245 type numbers designations

60245 IEC 03