60245 IEC 66
60245 IEC 66 is a IEC 60227 / IEC 60245 type numbers cable designation: 60245 IEC 66 = 60245 IEC 66: heavy polychloroprene sheathed flexible cable, 450/750 V (HAR twin H07RN-F); 60245 IEC 66 = 60245 IEC 66: heavy polychloroprene sheathed flexible cable, 450/750 V. 450/750 V; 1 to 5 cores, class 5: 1 core 1.5 to 400 mm2, 2 cores 1 to 25, 3 cores 1 to 95, 4 cores 1 to 150, 5 cores 1 to 25; IE4 rubber insulation, SE4 sheath (above 10 mm2 also SE3 inner and SE4 outer layer); 60 C (IEC 60245-4 cl. 5, Table 5). IEC 60245-4 (clause 5); HD 22.4 (HAR H07RN-F).
1 coding system recognises this code
IEC 60227 / IEC 60245 type numbers
| Symbol | Meaning |
|---|---|
60245 IEC 66 | 60245 IEC 66: heavy polychloroprene sheathed flexible cable, 450/750 V (HAR twin H07RN-F) |
60245 IEC 66 | 60245 IEC 66: heavy polychloroprene sheathed flexible cable, 450/750 V. 450/750 V; 1 to 5 cores, class 5: 1 core 1.5 to 400 mm2, 2 cores 1 to 25, 3 cores 1 to 95, 4 cores 1 to 150, 5 cores 1 to 25; IE4 rubber insulation, SE4 sheath (above 10 mm2 also SE3 inner and SE4 outer layer); 60 C (IEC 60245-4 cl. 5, Table 5). IEC 60245-4 (clause 5); HD 22.4 (HAR H07RN-F) |
What is 60245 IEC 66 cable?
60245 IEC 66: heavy polychloroprene sheathed flexible cable, 450/750 V. Rating: 450/750 V; 1 to 5 cores, class 5: 1 core 1.5 to 400 mm2, 2 cores 1 to 25, 3 cores 1 to 95, 4 cores 1 to 150, 5 cores 1 to 25; IE4 rubber insulation, SE4 sheath (above 10 mm2 also SE3 inner and SE4 outer layer); 60 C (IEC 60245-4 cl. 5, Table 5). Standard: IEC 60245-4 (clause 5); HD 22.4 (HAR H07RN-F).
IEC 60245-4 (standard): a heavy polychloroprene or equivalent synthetic elastomer sheathed flexible cable; 450/750 V; 1, 2, 3, 4 or 5 class 5 conductors; IE4 rubber insulation 0.8 mm (1 mm2) to 2.8 mm (400 mm2); optional proofed textile tape on cores above 4 mm2; SE4 sheath in one layer, or above 10 mm2 (multicore) two layers, SE3 inner and SE4 outer; Table 5: single core 1.5 to 400 mm2 (mean overall diameter 5.7 to 7.1 mm up to 37.4 to 46.8 mm), two cores 1 to 25, three cores 1 to 95, four cores 1 to 150, five cores 1 to 25 mm2; low-temperature tests only to 16 mm2 (5.4); 60 C in normal use (5.5). Makers: Helukabel p.12 (manufacturer): Polychloroprene sheathed flexible cable 07RN, H 07RN-F, 450/750 V, HD 22.4 S3, 245 IEC 65 and 245 IEC 66 (see 60245 IEC 65). Code designation (IEC 60245-1:2003+A1:2007 Annex A, p. 21 to 22): the first numeral is the basic class (0 non-sheathed for fixed wiring, 5 normal duty flexible, 6 heavy duty flexible, 7 special duty, 8 special application), the second the type within the class, so the number is read whole. The old spelling drops the 60 ('227 IEC 53' = '60227 IEC 53', IEC renumbering); Helukabel's table prints 227 / 245, EN-JV and Top Cable 60227. Core colours (IEC 60245-1:2003+A1:2007 4.1.2, p. 9): one and two cores no preferred scheme; three cores green-and-yellow, blue, brown or brown, black, grey; four cores green-and-yellow, brown, black, grey or blue, brown, black, grey; five cores green-and-yellow, blue, brown, black, grey or blue, brown, black, grey, black; above five cores by colour (green-and-yellow and blue in the outer layer) or by number (4.2). Drawn with the green-and-yellow set when the size says so (3G1.5), otherwise the set without it; two cores are drawn brown and blue (the HD 308 pair, as the standard prefers none); above five cores black numbered cores, the green-and-yellow core last. China: GB/T 5013.4-2008 is an identical adoption (IDT) of IEC 60245-4:2004 (SAMR record, checked 2026-11-09; the portal serves no text of it), so its values are this edition's. JB/T 8735.2-2016 (read in an English translation, site/burn-n18): its YCW (450/750 V, IE4 insulation, SE4 sheath or SE3 inner and SE4 outer layer; 6.4, 6.6) lists only what Table 5 here leaves out: 2 cores 35 to 95, 3 cores 120 and 150, 5 cores 35 to 150 mm2 and the 3+1, 3+2 and 4+1 builds from 2.5 mm2 (Table 7), so the YCW of this type's sizes is 60245 IEC 66 (GB/T 5013.4). Its YC is the SE3 sheathed heavy cable: 1 core 1 to 400 mm2 (the 1.5 and 400 mm2 mean overall diameters as here), 2 cores 1 to 95, 3 to 5 cores 1 to 150 mm2 (Tables 2 and 6).
Documents and pages the readings were taken from
- IEC 60245-4 ed. 3.0 (2011): clause 5 p. 13 to 14, Table 5 p. 15 to 16
- IEC 60245-1 ed. 4.1 (2003 + A1:2007): Annex A code designation p. 21 to 22; 4.1.2 preferred core colours p. 9, 4.2 cores by number pp. 9 to 10
- Helukabel 'Technical Information', table 'Comparison of harmonized cables with IEC, DIN VDE and HD', pdf p.12
IEC 60227 / IEC 60245 type numbers: how to read the cable type names
Work with 60245 IEC 66
Who makes or stocks this cable?
Makers and stockists of this cable family appear here as sponsors for your region, each marked "Sponsored"; a listing never changes what this page says about the cable.