Project requirements · Mechanical

Torsion (wind turbine loop)

The cable in a wind turbine drip loop survives repeated twisting as the nacelle yaws.

Open in the designer with this requirement

Constructions that meet it

  • Fine-wire class 5 or 6 conductor: changes no layer: a property of the conductor. Fine-wire class 5 or 6 conductor with short lay, tapes and lubricated layers that let the elements slide (class 5/6 copper or aluminium). Drawbacks: Class 6 is larger for the same section.
  • Rubber or PUR sheath and insulation: changes no layer: a property of the sheath compound. Rubber or TPE / PUR sheath and insulation (EPR, EM2, cross-linked polyolefin) (rubber / PUR). Drawbacks: Cost.

Writing a tender? Pro writes this requirement into your specification, ready to copy. Open in the designer with this requirement · See Pro

Tests

  • Maker torsion tests (classes as printed by Lapp; their origin standard not found): ± 150 °/m at 1 rpm. Pass: TW-0: 5000 cycles at ≥ +5 °C; TW-1: 2000 cycles at ≥ -20 °C; TW-2: 2000 cycles at ≥ -40 °C
  • Nexans WINDLINK: ± 150 °/m (± 100 °/m for 400 mm²). Pass: 2000 cycles, no copper wire broken
  • Helukabel tower test: ± 150 ° per 1 m. Pass: more than 16,000 cycles (WK 137)

How specifications state it

Named as '± 150 °/m, N cycles at T °C'; no single international standard found.

Where it is asked for

  • wind turbines (loop between nacelle and tower)
  • robots