Project requirements · Mechanical

Abrasion resistance

The sheath resists wear from dragging, pulling and rubbing.

Open in the designer with this requirement

Constructions that meet it

  • PUR, TPU or TPE sheath: changes no layer: a property of the sheath compound. PUR or TPU outer sheath (PUR / TPU). Drawbacks: Cost; PUR not halogen free unless FR grade (typical).
  • Hard polyamide (nylon) jacket over the sheath: changes the cable's layers. Thin nylon jacket over the sheath (PA). Drawbacks: Low friction too (VESTAMID listing).
  • Thicker sheath: changes the cable's layers. Thicker sheath (same compound, larger thickness). Drawbacks: Diameter, weight.

Writing a tender? Pro writes this requirement into your specification, ready to copy. Open in the designer with this requirement · See Pro

Tests

  • EN 50289-3-7: abrasion resistance of the cable sheath (communication cables). Pass: not read
  • EN 50289-3-8: abrasion resistance of sheath markings. Pass: not read
  • IS 10810 Part 55 (India): abrasive wear of the outer sheath of armoured cables. Pass: not read

How specifications state it

Often only 'abrasion resistant'; Lapp PUR sheets claim it without a test.

Where it is asked for

  • mining and trailing cables
  • drag chains
  • pulling into long ducts