Z1G-YMz1Kas

Z1G-YMz1Kas is a NEN / KEMA type names (Netherlands) cable designation: Z1 = LSZH (Low Smoke Zero Halogen Compund) Outersheath; G- = Armour; Y = Cross-linked polyethylene (XLPE) insulation; Mz1K = Low Smoke Zero Halojen Sheathed Cable; as = With Earthing Screen; Z1G-YMz1Kas = Z1G-YMz1Kas: Dutch armoured halogen-free 0,6/1 kV ground cable, stranded copper conductors in XLPE insulation, a halogen-free inner sheath, an earth conductor, armour and a grey halogen-free outer sheath. 0,6/1 kV (TKF). KEMA-KEUR, installed to NEN 1010 (TKF).

2 coding systems recognise this code

NEN / KEMA type names (Netherlands)

SymbolMeaning
Z1LSZH (Low Smoke Zero Halogen Compund) Outersheath
G-Armour
YCross-linked polyethylene (XLPE) insulation
Mz1KLow Smoke Zero Halojen Sheathed Cable
asWith Earthing Screen
Z1G-YMz1KasZ1G-YMz1Kas: Dutch armoured halogen-free 0,6/1 kV ground cable, stranded copper conductors in XLPE insulation, a halogen-free inner sheath, an earth conductor, armour and a grey halogen-free outer sheath. 0,6/1 kV (TKF). KEMA-KEUR, installed to NEN 1010 (TKF)

NEN 3207 / KEMA (Netherlands)

SymbolMeaning
Z1Low Smoke Zero Halogen Compound
G-Armoured (Round Or Flat Steel Wire, Or Steel Tape)
YCross-Linked Polyethylene (XLPE)
Mz1KLow Smoke Zero Halogen (LS0H) Sheathed Cable
asWith Earthing Screen

How to read a NEN 3207 / KEMA (Netherlands) cable code

What is Z1G-YMz1Kas cable?

Z1G-YMz1Kas: Dutch armoured halogen-free 0,6/1 kV ground cable, stranded copper conductors in XLPE insulation, a halogen-free inner sheath, an earth conductor, armour and a grey halogen-free outer sheath. Rating: 0,6/1 kV (TKF). Standard: KEMA-KEUR, installed to NEN 1010 (TKF).

TKF Z1G-YMz1Kas Cca 0,6/1 kV (sheet of 20-10-2026): armoured halogen-free power cable for NEN 1010 installations, for direct burial; copper class 2 stranded; XLPE insulation; armour: yes (its form is not printed); sheath material MBZH, grey; KEMA-KEUR; Cca-s1,d1,a1. Letters (HD 620 S3 10-J Appendix D): Z1 outer covering LS0H (position 4), G armour (position 3), Y XLPE, Mz1K LS0H sheath, as earth screen. The armour is drawn as steel wires and the earth conductor as copper wires: typical values, the sheet prints neither.

Documents and pages the readings were taken from

NEN / KEMA type names (Netherlands): how to read the cable type names

Fire behaviour (EU CPR)

  • Halogen-free compound (Z1, Z1G-YMz1Kas). Under the CPR this shows in the additional classes: acidity a1 to a3 (EN 60754-2) and smoke s1 to s3 (EN 50399; s1a and s1b add the 3 m cube test EN 61034-2). The main class, Aca to Fca, depends on the whole construction.

    Typically targeted, as declared by makers for this kind of construction in the examples this site checked (not the class of this cable):

    Listed as sources, alphabetically by maker. No maker pays to appear here.

  • Low-smoke compound (Mz1K). Smoke is graded s1 to s3 on the EN 50399 ladder; s1a and s1b add the 3 m cube test EN 61034-2.

A CPR class is declared by the maker in its Declaration of Performance and printed on the sheath (EN 50575 cl 7). This decoder does not assign one. What the CPR classes mean →

Sources: EN 13501-6 draft and FprEN 50575:2014 final draft (drafts, not the published texts); IEC 60332-3-24:2000+A1:2008; EN 13501-3 draft A2.

Laying, sizes and datasheet: Z1G-YMz1Kas

Terms on this page: oversheath (outer sheath)

Work with Z1G-YMz1Kas

Who makes or stocks this cable?

Makers and stockists of this cable family appear here as sponsors for your region, each marked "Sponsored"; a listing never changes what this page says about the cable.

Related cables

More NEN / KEMA type names (Netherlands) designations

Z1G-YMz1Kas