YXC2V-R

YXC2V-R is a HAR: HD 361 harmonised designation (CENELEC) cable designation: Y = Turkish TS Type For Medium And Heavy Operating Conditions (e.g. YXC7V-R); X = Cross-Linked Polyethylene (XLPE); C2 = Copper Sheath; V = Polyvinyl Chloride (PVC); -R = Multi-Wire, Round-Section, Class 2.

1 coding system recognises this code

Standard, worked reading and related types

Worked reading of YXC2V-R:

  • YXC2V-R: Y = Turkish TS Type For Medium And Heavy Operating Conditions (e.g. YXC7V-R); X = Cross-Linked Polyethylene (XLPE); C2 = Copper Sheath; V = Polyvinyl Chloride (PVC); -R = Multi-Wire, Round-Section, Class 2

Related cable types: YXC7V-R · YXZ2V-R · YXC4V-R · YXC8V-R · YXC3V-R · YXC5V-R

HAR: HD 361 harmonised designation (CENELEC)

SymbolMeaning
YTurkish TS Type For Medium And Heavy Operating Conditions (e.g. YXC7V-R)
XCross-Linked Polyethylene (XLPE)
C2Copper Sheath
VPolyvinyl Chloride (PVC)
-RMulti-Wire, Round-Section, Class 2

How to read a HAR: HD 361 harmonised designation (CENELEC) cable code

How to read a HAR: HD 361 harmonised designation (CENELEC) cable code

A HAR: HD 361 harmonised designation (CENELEC) designation (Europe (CENELEC)) is a row of letter groups, and each group stands for one part of the cable: conductor, insulation, screen, armour, sheath, or the standard it follows. The decoder knows 129 symbols for this system.

What does Y mean in a HAR: HD 361 harmonised designation (CENELEC) cable code? Y means Turkish TS Type For Medium And Heavy Operating Conditions (e.g. YXC7V-R).

What does X mean in a HAR: HD 361 harmonised designation (CENELEC) cable code? X means Cross-Linked Polyethylene (XLPE); or Without Green-Yellow Protective Conductor (Multiplication Sign); or Based On A Harmonised Design (Like S).

What does C2 mean in a HAR: HD 361 harmonised designation (CENELEC) cable code? C2 means Copper Sheath.

What does V mean in a HAR: HD 361 harmonised designation (CENELEC) cable code? V means Polyvinyl Chloride (PVC).

What does -R mean in a HAR: HD 361 harmonised designation (CENELEC) cable code? -R means Multi-Wire, Round-Section, Class 2.

Fire behaviour (EU CPR)

A CPR class is declared by the maker in its Declaration of Performance and printed on the sheath (EN 50575 cl 7). This decoder does not assign one. What the CPR classes mean →

Sources: EN 13501-6 draft and FprEN 50575:2014 final draft (drafts, not the published texts); IEC 60332-3-24:2000+A1:2008; EN 13501-3 draft A2.

Work with YXC2V-R

Who makes or stocks this cable?

Makers and stockists of this cable family appear here as sponsors for your region, each marked "Sponsored"; a listing never changes what this page says about the cable.

Related cables

More HAR: HD 361 harmonised designation (CENELEC) designations

YXC2V-R