YFY

YFY is a BIS type names (India) cable designation: Y = PVC insulation; F = Flat Galvanized Steel Wire (Strip) Armour; Y = PVC outer sheath; YFY = YFY: copper conductors, PVC insulation, inner sheath, galvanised steel strip (formed wire) armour, PVC outer sheath (IS 1554-1, up to 1100 V). Up to and including 1100 V a.c.; d.c. up to and including 1500 V to earth; 70 C (Type A PVC) or 85 C (Type C, marked HR 85), 160 C short circuit. IS 1554 (Part 1):1988 (reaffirmed 2020), cable code cl. 17.3.

6 coding systems recognise this code

BIS type names (India)

SymbolMeaning
YPVC insulation
FFlat Galvanized Steel Wire (Strip) Armour
YPVC outer sheath
YFYYFY: copper conductors, PVC insulation, inner sheath, galvanised steel strip (formed wire) armour, PVC outer sheath (IS 1554-1, up to 1100 V). Up to and including 1100 V a.c.; d.c. up to and including 1500 V to earth; 70 C (Type A PVC) or 85 C (Type C, marked HR 85), 160 C short circuit. IS 1554 (Part 1):1988 (reaffirmed 2020), cable code cl. 17.3

DIN VDE 0271/0276 power cables (Germany)

SymbolMeaning
YPolyvinyl Chloride (PVC)
FFlat Galvanized Steel Wire
YPolyvinyl Chloride (PVC)

How to read a DIN VDE 0271/0276 power cables (Germany) cable code

DIN VDE 0250 cords, control and special cables (Germany)

SymbolMeaning
YPolyvinyl Chloride (PVC); Control-Cable Key: Thermoplastics In General
FFlexible (Fine-Stranded Conductor, As In SiHF, SiF) Or Flexible Luminaire Wire
YPolyvinyl Chloride (PVC); Control-Cable Key: Thermoplastics In General

How to read a DIN VDE 0250 cords, control and special cables (Germany) cable code

China (GB / JB/T / MT cable model codes)

SymbolMeaning
YPolyethylene (PE) Or Polyolefin
FChloroprene Rubber
YPolyethylene (PE) Or Polyolefin

How to read a China (GB / JB/T / MT cable model codes) cable code

India (IS 1554 / IS 7098 cable code)

SymbolMeaning
YPolyvinyl Chloride (PVC)
FFlat Galvanized Steel Wire (Strip) Armour
YPolyvinyl Chloride (PVC)

How to read a India (IS 1554 / IS 7098 cable code) cable code

NEN 3207 / KEMA (Netherlands)

SymbolMeaning
YCross-Linked Polyethylene (XLPE)
FFine-Wired In Flexible Cables-Class 5
YCross-Linked Polyethylene (XLPE)

How to read a NEN 3207 / KEMA (Netherlands) cable code

Fire behaviour (EU CPR)

A CPR class is declared by the maker in its Declaration of Performance and printed on the sheath (EN 50575 cl 7). This decoder does not assign one. What the CPR classes mean →

Sources: EN 13501-6 draft and FprEN 50575:2014 final draft (drafts, not the published texts); IEC 60332-3-24:2000+A1:2008; EN 13501-3 draft A2.

YFY as the cable designer builds it, 3x16 1100 V

Overall diameter 19.9 mm, about 1,000 kg/km. Nominal values from the standard's tables for this size, computed, not a maker's data.

LayerMaterialThickness, mmOver the layer, mm
InsulationPVC1.06.9
FillerPP14.9
Inner covering / beddingPVC0.3015.5
Wire armourSteel12 × 0.8017.1
SheathPVC1.419.9

YFY on a drum

The smallest drum that passes every check, for 19.9 mm and about 1,000 kg/km as the cable designer builds it. Drums as their makers print them; lengths are estimates within a few per cent of the cable makers' own tables: whole layers, wound diameter 1.05 × OD, 50 mm freeboard under the flange rim.

LengthDrum size (its makers)LayersGross weight
500 mKTG 10 (1000 mm flange), wood KTG drums (Europe), Bayka, KTG9 of 9571–578 kg
1,000 mKTG 12 (1250 mm flange), wood KTG drums (Europe), Bayka, KTG12 of 121,144–1,165 kg

Barrel at least 15 × OD = 298 mm for a cable of this kind (Low voltage, multi-core): KTG table, the cable's datasheet wins. A load rating is the drum maker's own.

Other lengths, drums and weights: the cable drum calculator

Load it on a truck: 1000 m on its drum in the loading planner

Laying, sizes and datasheet: YFY

Terms on this page: oversheath (outer sheath)

Selling this cable? Open it in the designer and get a datasheet with your logo (Pro). Open the cable designer · See Pro

Work with YFY

Related cables

More BIS type names (India) designations