VO-YMvKas

VO-YMvKas is a NEN / KEMA type names (Netherlands) cable designation: V = PVC outer sheath; O- = Galvanized Steel Wire Braid; Y = Cross-linked polyethylene (XLPE) insulation; MvK = PVC sheath under the armour; as = With Earthing Screen; VO-YMvKas = VO-YMvKas: Dutch braided 0,6/1 kV ground cable, copper conductors in XLPE insulation, a PVC inner sheath, an earth conductor of tinned copper strands under a galvanised steel wire braid, and a grey PVC outer sheath. 0,6/1 kV, 90 C conductor, test voltage 3,5 kV (TKF). HD 604 Part 4 Section D (Waskönig); KEMA-KEUR, installed to NEN 1010.

2 coding systems recognise this code

NEN / KEMA type names (Netherlands)

SymbolMeaning
VPVC outer sheath
O-Galvanized Steel Wire Braid
YCross-linked polyethylene (XLPE) insulation
MvKPVC sheath under the armour
asWith Earthing Screen
VO-YMvKasVO-YMvKas: Dutch braided 0,6/1 kV ground cable, copper conductors in XLPE insulation, a PVC inner sheath, an earth conductor of tinned copper strands under a galvanised steel wire braid, and a grey PVC outer sheath. 0,6/1 kV, 90 C conductor, test voltage 3,5 kV (TKF). HD 604 Part 4 Section D (Waskönig); KEMA-KEUR, installed to NEN 1010

NEN 3207 / KEMA (Netherlands)

SymbolMeaning
VPolyvinyl Chloride (PVC)
O-Braid (Braid Armour)
YCross-Linked Polyethylene (XLPE)
MvKPVC Sheathed Cable
asWith Earthing Screen

How to read a NEN 3207 / KEMA (Netherlands) cable code

What is VO-YMvKas cable?

VO-YMvKas: Dutch braided 0,6/1 kV ground cable, copper conductors in XLPE insulation, a PVC inner sheath, an earth conductor of tinned copper strands under a galvanised steel wire braid, and a grey PVC outer sheath. Rating: 0,6/1 kV, 90 C conductor, test voltage 3,5 kV (TKF). Standard: HD 604 Part 4 Section D (Waskönig); KEMA-KEUR, installed to NEN 1010.

TKF VO-YMvKas Dca 0,6/1 kV (sheet of 20-10-2026): braided power cable for NEN 1010 installations, for direct burial; XLPE insulation; litze: yes; armour: braid (vlechtwerk); PVC sheath; KEMA-KEUR; test voltage 3,5 kV. Waskönig VO-YMvKas Dca: XLPE (VPE) insulated copper conductors, class 1 solid, concentric conductor of steel and copper wires, grey PVC sheath, HD 604 4D. Kabelwerk Eupen VO-YMvKas: solid copper, XLPE insulation, filler, PVC inner sheath, a braid of galvanised steel wires over a layer of tinned copper strands, grey flame-retardant PVC outer sheath. Athilex VO-YMVKAS / VG-YMVKAS: galvanised steel wire braid with a tinned copper earth conductor, sizes printed as 4x6/6, 3x25/16, 4x95/50 (the second number the earth conductor). Letters by NEN 3207 (HD 620 S3 10-J Appendix D, order 4 <- 3 <- 2 <- 1, then 5): V the outer covering (PVC), O the mechanical protection, a braid armour ("O armure en forme de tresse", Cebeo Tome 04 2011 p. 29; "O: Stalen vlechtwerk", Standaardbestek 270 v3.0 1.2.6.1), Y the XLPE insulation, MvK the PVC (inner) sheath, as the earthing screen ("as avec ecran de mise a la terre", Cebeo p. 30); the size "4x25+as16" gives its section (Cebeo p. 31).

Documents and pages the readings were taken from

NEN / KEMA type names (Netherlands): how to read the cable type names

Fire behaviour (EU CPR)

A CPR class is declared by the maker in its Declaration of Performance and printed on the sheath (EN 50575 cl 7). This decoder does not assign one. What the CPR classes mean →

Sources: EN 13501-6 draft and FprEN 50575:2014 final draft (drafts, not the published texts); IEC 60332-3-24:2000+A1:2008; EN 13501-3 draft A2.

Laying, sizes and datasheet: VO-YMvKas

Terms on this page: oversheath (outer sheath)

Work with VO-YMvKas

Who makes or stocks this cable?

Makers and stockists of this cable family appear here as sponsors for your region, each marked "Sponsored"; a listing never changes what this page says about the cable.

Related cables

More NEN / KEMA type names (Netherlands) designations

VO-YMvKas