VG-YMvKas

VG-YMvKas is a NEN / KEMA type names (Netherlands) cable designation: V = PVC outer sheath; G- = Armoured (Round Or Flat Steel Wire); Y = Cross-linked polyethylene (XLPE) insulation; MvK = PVC sheath under the armour; as = With Earthing Screen; VG-YMvKas = VG-YMvKas: Dutch armoured 0,6/1 kV ground cable, copper conductors in XLPE insulation, a PVC inner sheath, one concentric layer of steel armour wires and copper earth wires (as), and a grey PVC outer sheath. 0,6/1 kV, 90 C conductor, 250 C short circuit (Waskönig). HD 604 Part 4 Section D (Waskönig, "based upon").

2 coding systems recognise this code

NEN / KEMA type names (Netherlands)

SymbolMeaning
VPVC outer sheath
G-Armoured (Round Or Flat Steel Wire)
YCross-linked polyethylene (XLPE) insulation
MvKPVC sheath under the armour
asWith Earthing Screen
VG-YMvKasVG-YMvKas: Dutch armoured 0,6/1 kV ground cable, copper conductors in XLPE insulation, a PVC inner sheath, one concentric layer of steel armour wires and copper earth wires (as), and a grey PVC outer sheath. 0,6/1 kV, 90 C conductor, 250 C short circuit (Waskönig). HD 604 Part 4 Section D (Waskönig, "based upon")

NEN 3207 / KEMA (Netherlands)

SymbolMeaning
VPolyvinyl Chloride (PVC)
G-Armoured (Round Or Flat Steel Wire, Or Steel Tape)
YCross-Linked Polyethylene (XLPE)
MvKPVC Sheathed Cable
asWith Earthing Screen

How to read a NEN 3207 / KEMA (Netherlands) cable code

What is VG-YMvKas cable?

VG-YMvKas: Dutch armoured 0,6/1 kV ground cable, copper conductors in XLPE insulation, a PVC inner sheath, one concentric layer of steel armour wires and copper earth wires (as), and a grey PVC outer sheath. Rating: 0,6/1 kV, 90 C conductor, 250 C short circuit (Waskönig). Standard: HD 604 Part 4 Section D (Waskönig, "based upon").

Waskönig VG-YMvKas Dca: "VPE-isoliert mit Cu-Leitern und konz. Leiter aus Stahl- u. Cu-Drähten" (XLPE insulated, copper conductors, a concentric conductor of steel and copper wires), grey PVC sheath, 0,6/1 kV, based upon HD 604 4D, sizes 3x10 (class 2) to 4x240 (sector from 35 mm2). VG-YMvKhas adds auxiliary cores (h, Cebeo p. 30: "h avec conducteur(s) auxiliaire(s)"). The steel and copper wires lie in one layer; the drawing puts the copper earth wires under the steel ones.

Documents and pages the readings were taken from

NEN / KEMA type names (Netherlands): how to read the cable type names

Fire behaviour (EU CPR)

A CPR class is declared by the maker in its Declaration of Performance and printed on the sheath (EN 50575 cl 7). This decoder does not assign one. What the CPR classes mean →

Sources: EN 13501-6 draft and FprEN 50575:2014 final draft (drafts, not the published texts); IEC 60332-3-24:2000+A1:2008; EN 13501-3 draft A2.

Laying, sizes and datasheet: VG-YMvKas

Terms on this page: oversheath (outer sheath)

Work with VG-YMvKas

Who makes or stocks this cable?

Makers and stockists of this cable family appear here as sponsors for your region, each marked "Sponsored"; a listing never changes what this page says about the cable.

Related cables

More NEN / KEMA type names (Netherlands) designations

VG-YMvKas